Accuracy of integration of dental cast and cephalograms compared with cone-beam computed tomography: a comparative study

被引:1
|
作者
Dai, Fanfan [1 ,3 ,4 ,5 ]
Chen, Si [2 ,3 ,4 ,5 ]
Feng, Tingting [6 ]
Lu, Wenhsuan [2 ,3 ,4 ,5 ]
Chen, Gui [2 ,3 ,4 ,5 ]
Jiang, Jiuhui [2 ,3 ,4 ,5 ]
Jiang, Ruoping [2 ,3 ,4 ,5 ]
Lin, Jiuxiang [2 ,3 ,4 ,5 ,7 ]
Han, Bing [2 ,3 ,4 ,5 ,7 ]
Xu, Tianmin [2 ,3 ,4 ,5 ]
机构
[1] Peking Univ, Clin Div 2, Sch & Hosp Stomatol, Beijing, Peoples R China
[2] Peking Univ, Dept Orthodont, Sch & Hosp Stomatol, Beijing, Peoples R China
[3] Natl Clin Res Ctr Oral Dis, Beijing, Peoples R China
[4] Natl Engn Lab Digital & Mat Technol Stomatol, Beijing, Peoples R China
[5] Beijing Key Lab Digital Stomatol Beijing China, Beijing, Peoples R China
[6] Tongji Univ, Dept Orthodont, Affiliated Stomatol Hosp, Shanghai, Peoples R China
[7] Peking Univ, Craniofacial Growth & Dev Ctr, Beijing, Peoples R China
基金
北京市自然科学基金; 对外科技合作项目(国际科技项目);
关键词
Orthodontic; Dental cast; Cephalograms; Cone-beam computed tomography; Registration; Three dimensional; PALATAL RUGAE; SUPERIMPOSITION; IMPLANT; CHILDREN; SKELETAL; ERUPTION; GROWTH; MOLARS; MODEL;
D O I
10.1007/s10266-022-00732-6
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
This study proposes a method that integrates maxillary dental cast and cephalograms and evaluates its accuracy compared with cone-beam computed tomography (CBCT) scans. The study sample comprised 20 adult patients with records of dental casts, cephalograms, and craniofacial CBCT scans. The maxillary dental cast was integrated with lateral and frontal cephalograms based on best-fit registration of palatal and dental outline curves from dental cast with cephalogram tracings. Linear measurement was conducted to assess the intra- and inter-examiner reproducibility of the proposed integration method using intraclass correlation coefficients; linear and angular measurements were conducted to assess its accuracy with CBCT scans as a standard reference. Paired t test, one sample t test, and mean +/- standard deviation of the absolute value of difference were used to compare the integrated images and CBCT. The integration method showed good intra- and inter-examiner reproducibility (intraclass correlation coefficients > 0.98). The differences in linear and angular measurements between the integrated images and CBCT were not statistically significant but with a large deviation. When absolute value of difference was computed, the linear distance error was 0.51 +/- 0.34 mm, the tooth point coordinate errors in X, Y and Z axes were 0.22 +/- 0.22, 0.38 +/- 0.32 and 0.21 +/- 0.21 mm, respectively; the angular error in pitch, roll and yaw of the dental cast was 0.82 +/- 0.51, 0.92 +/- 0.59 and 0.80 +/- 0.41 degree, respectively. The proposed method for integration of dental cast and cephalograms showed good reproducibility and acceptable accuracy compared with CBCT. It could be helpful for researchers to study three-dimensional tooth growth changes using the existing craniofacial growth data especially cephalograms.
引用
收藏
页码:238 / 247
页数:10
相关论文
共 50 条
  • [11] Finger fractures imaging: accuracy of cone-beam computed tomography and multislice computed tomography
    Niccolò Faccioli
    Giovanni Foti
    Marco Barillari
    Andrea Atzei
    Roberto Pozzi Mucelli
    Skeletal Radiology, 2010, 39 : 1087 - 1095
  • [12] Accuracy and reliability of stitched cone-beam computed tomography images
    Egbert, Nicholas
    Cagna, David R.
    Ahuja, Swati
    Wicks, Russell A.
    IMAGING SCIENCE IN DENTISTRY, 2015, 45 (01) : 41 - 47
  • [13] Create virtual dentoskeletal model by superimposing digital dental cast into cone-beam computed tomography scan
    Mahmood, Reem Shakir
    Hamandi, Sadiq Jafer Abbas
    Al-Mahdi, Akmam Hamdy
    INTERNATIONAL JOURNAL OF COMPUTER ASSISTED RADIOLOGY AND SURGERY, 2024, 19 (09) : 1855 - 1864
  • [14] Evaluating the mandible with cone-beam computed tomography
    Stratemann, Scott A.
    Huang, John C.
    Maki, Koutaro
    Hatcher, David C.
    Miller, Arthur J.
    AMERICAN JOURNAL OF ORTHODONTICS AND DENTOFACIAL ORTHOPEDICS, 2010, 137 (04) : S58 - S70
  • [15] Maxillary sinusitis as a diagnostical adverse finding of the dental cone-beam computed tomography study
    Schreindorfer Karoly
    Kiss Agnes
    Marada Gyula
    ORVOSI HETILAP, 2017, 158 (44) : 1747 - 1753
  • [16] Detection of dental root fractures by using cone-beam computed tomography
    Wang, P.
    Yan, X. B.
    Lui, D. G.
    Zhang, W. L.
    Zhang, Y.
    Ma, X. C.
    DENTOMAXILLOFACIAL RADIOLOGY, 2011, 40 (05) : 290 - 298
  • [17] Clinical utility of dental cone-beam computed tomography: current perspectives
    Jaju, Prashant P.
    Jaju, Sushma P.
    CLINICAL COSMETIC AND INVESTIGATIONAL DENTISTRY, 2014, 6 : 29 - 43
  • [18] Cone-Beam Computed Tomography: A useful tool for dental age estimation?
    Maret, D.
    Peters, O. A.
    Dedouit, F.
    Telmon, N.
    Sixou, M.
    MEDICAL HYPOTHESES, 2011, 76 (05) : 700 - 702
  • [19] Evaluation of Dental Root Fracture Using Cone-beam Computed Tomography
    Wang, Pei
    Yan, Xue Bing
    Liu, Deng Gao
    Zhang, Wan Lin
    Zhang, Zu Yan
    Ma, Xu Chen
    CHINESE JOURNAL OF DENTAL RESEARCH, 2010, 13 (01) : 31 - 35
  • [20] Zygomaticofacial foramen location accuracy and reliability in cone-beam computed tomography
    del Neri, Nathalia Bigelli
    Araujo-Pires, Ana Claudia
    Andreo, Jesus Carlos
    Fisher Rubira-Bullen, Izabel Regina
    Ferreira Junior, Osny
    ACTA ODONTOLOGICA SCANDINAVICA, 2014, 72 (02) : 157 - 160