Accuracy of integration of dental cast and cephalograms compared with cone-beam computed tomography: a comparative study

被引:1
|
作者
Dai, Fanfan [1 ,3 ,4 ,5 ]
Chen, Si [2 ,3 ,4 ,5 ]
Feng, Tingting [6 ]
Lu, Wenhsuan [2 ,3 ,4 ,5 ]
Chen, Gui [2 ,3 ,4 ,5 ]
Jiang, Jiuhui [2 ,3 ,4 ,5 ]
Jiang, Ruoping [2 ,3 ,4 ,5 ]
Lin, Jiuxiang [2 ,3 ,4 ,5 ,7 ]
Han, Bing [2 ,3 ,4 ,5 ,7 ]
Xu, Tianmin [2 ,3 ,4 ,5 ]
机构
[1] Peking Univ, Clin Div 2, Sch & Hosp Stomatol, Beijing, Peoples R China
[2] Peking Univ, Dept Orthodont, Sch & Hosp Stomatol, Beijing, Peoples R China
[3] Natl Clin Res Ctr Oral Dis, Beijing, Peoples R China
[4] Natl Engn Lab Digital & Mat Technol Stomatol, Beijing, Peoples R China
[5] Beijing Key Lab Digital Stomatol Beijing China, Beijing, Peoples R China
[6] Tongji Univ, Dept Orthodont, Affiliated Stomatol Hosp, Shanghai, Peoples R China
[7] Peking Univ, Craniofacial Growth & Dev Ctr, Beijing, Peoples R China
基金
北京市自然科学基金; 对外科技合作项目(国际科技项目);
关键词
Orthodontic; Dental cast; Cephalograms; Cone-beam computed tomography; Registration; Three dimensional; PALATAL RUGAE; SUPERIMPOSITION; IMPLANT; CHILDREN; SKELETAL; ERUPTION; GROWTH; MOLARS; MODEL;
D O I
10.1007/s10266-022-00732-6
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
This study proposes a method that integrates maxillary dental cast and cephalograms and evaluates its accuracy compared with cone-beam computed tomography (CBCT) scans. The study sample comprised 20 adult patients with records of dental casts, cephalograms, and craniofacial CBCT scans. The maxillary dental cast was integrated with lateral and frontal cephalograms based on best-fit registration of palatal and dental outline curves from dental cast with cephalogram tracings. Linear measurement was conducted to assess the intra- and inter-examiner reproducibility of the proposed integration method using intraclass correlation coefficients; linear and angular measurements were conducted to assess its accuracy with CBCT scans as a standard reference. Paired t test, one sample t test, and mean +/- standard deviation of the absolute value of difference were used to compare the integrated images and CBCT. The integration method showed good intra- and inter-examiner reproducibility (intraclass correlation coefficients > 0.98). The differences in linear and angular measurements between the integrated images and CBCT were not statistically significant but with a large deviation. When absolute value of difference was computed, the linear distance error was 0.51 +/- 0.34 mm, the tooth point coordinate errors in X, Y and Z axes were 0.22 +/- 0.22, 0.38 +/- 0.32 and 0.21 +/- 0.21 mm, respectively; the angular error in pitch, roll and yaw of the dental cast was 0.82 +/- 0.51, 0.92 +/- 0.59 and 0.80 +/- 0.41 degree, respectively. The proposed method for integration of dental cast and cephalograms showed good reproducibility and acceptable accuracy compared with CBCT. It could be helpful for researchers to study three-dimensional tooth growth changes using the existing craniofacial growth data especially cephalograms.
引用
收藏
页码:238 / 247
页数:10
相关论文
共 50 条
  • [1] Comparative analysis of upper airway volume with lateral cephalograms and cone-beam computed tomography
    Feng, Xin
    Li, Gang
    Qu, Zhenyu
    Liu, Lin
    Nasstrom, Karin
    Shi, Xie-Qi
    AMERICAN JOURNAL OF ORTHODONTICS AND DENTOFACIAL ORTHOPEDICS, 2015, 147 (02) : 197 - 204
  • [2] Comparative study of jaws with multislice computed tomography and cone-beam computed tomography
    Carrafiello, G.
    Dizonno, M.
    Colli, V.
    Strocchi, S.
    Taubert, S. Pozzi
    Leonardi, A.
    Giorgianni, A.
    Barresi, M.
    Macchi, A.
    Bracchi, E.
    Conte, L.
    Fugazzola, C.
    RADIOLOGIA MEDICA, 2010, 115 (04): : 600 - 611
  • [3] Clinical guidelines for dental cone-beam computed tomography
    Takafumi Hayashi
    Yoshinori Arai
    Toru Chikui
    Sachiko Hayashi-Sakai
    Kazuya Honda
    Hiroko Indo
    Taisuke Kawai
    Kaoru Kobayashi
    Shumei Murakami
    Masako Nagasawa
    Munetaka Naitoh
    Eiji Nakayama
    Yutaka Nikkuni
    Hideyoshi Nishiyama
    Noriaki Shoji
    Shigeaki Suenaga
    Ray Tanaka
    Oral Radiology, 2018, 34 : 89 - 104
  • [4] A comparative study of the reproducibility of landmark identification on posteroanterior and anteroposterior cephalograms generated from cone-beam computed tomography scans
    Na, Eui-Ri
    Aljawad, Hussein
    Lee, Kyung-Min
    Hwang, Hyeon-Shik
    KOREAN JOURNAL OF ORTHODONTICS, 2019, 49 (01) : 41 - 48
  • [5] Clinical guidelines for dental cone-beam computed tomography
    Hayashi, Takafumi
    Arai, Yoshinori
    Chikui, Toru
    Hayashi-Sakai, Sachiko
    Honda, Kazuya
    Indo, Hiroko
    Kawai, Taisuke
    Kobayashi, Kaoru
    Murakami, Shumei
    Nagasawa, Masako
    Naitoh, Munetaka
    Nakayama, Eiji
    Nikkuni, Yutaka
    Nishiyama, Hideyoshi
    Shoji, Noriaki
    Suenaga, Shigeaki
    Tanaka, Ray
    ORAL RADIOLOGY, 2018, 34 (02) : 89 - 104
  • [6] A New Method for the Integration of Digital Dental Models and Cone-beam Computed Tomography Images
    Lin, Hsiu-Hsia
    Chiang, Wen-Chung
    Lo, Lun-Jou
    Wang, Chien-Hsuan
    2013 35TH ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY (EMBC), 2013, : 2328 - 2331
  • [7] Use of Reference Ear Plug to improve accuracy of lateral cephalograms generated from cone-beam computed tomography scans
    Hwang, Hyeon-Shik
    Lee, Kyung-Min
    Uhm, Gi-Soo
    Cho, Jin-Hyoung
    McNamara, James A., Jr.
    KOREAN JOURNAL OF ORTHODONTICS, 2013, 43 (02) : 54 - 61
  • [8] Finger fractures imaging: accuracy of cone-beam computed tomography and multislice computed tomography
    Faccioli, Niccolo
    Foti, Giovanni
    Barillari, Marco
    Atzei, Andrea
    Mucelli, Roberto Pozzi
    SKELETAL RADIOLOGY, 2010, 39 (11) : 1087 - 1095
  • [9] A Phantom Study on Target Localization Accuracy Using Cone-Beam Computed Tomography
    Yan, Hui
    Zhang, Liwei
    Yin, Fang-Fang
    CLINICAL MEDICINE INSIGHTS-ONCOLOGY, 2008, 2 : 501 - 510
  • [10] Accuracy of laser-scanned models compared to plaster models and cone-beam computed tomography
    Kim, Jooseong
    Heo, Giseon
    Lagravere, Manuel O.
    ANGLE ORTHODONTIST, 2014, 84 (03) : 443 - 450