Research on the influence of underground seepage on regional heat accumulation of ground source heat pump heat exchanger

被引:10
作者
Shao, Qi [1 ]
Zhang, Chengwei [2 ]
Wang, Bingfeng [1 ]
Chen, Tao [2 ]
Sun, Mingyuan [1 ]
Yin, Huiyong [2 ]
机构
[1] Shandong Geol & Mineral Engn Grp Co Ltd, Jinan 250013, Peoples R China
[2] Shandong Univ Sci & Technol, Coll Earth Sci & Engn, Qingdao 266590, Peoples R China
关键词
Heat accumulation of ground source heat pump system; Underground seepage; Thermal response test; Pumping / irrigation test; Numerical simulation;
D O I
10.1016/j.tsep.2024.102391
中图分类号
O414.1 [热力学];
学科分类号
摘要
During the long-term operation of the ground source heat pump system, the temperature imbalance of the rock and soil around the heat exchanger results in the deterioration of the performance of the ground source heat pump system. Through previous projects, it has been found that in the area of underground seepage speed, it is helpful to alleviate the heat or cold accumulation of rock and soil mass around the ground source heat pump system. Based on this, two test sites in Zhangqiu District, Jinan City, Shandong Province, were selected to conduct pumping and irrigation tests to change the underground seepage velocity, determine the flow velocity through isotopic tracer tests, obtain soil thermal physical parameters and simulate heat accumulation through thermal response tests, and establish long-term numerical simulation through Opengeosys to synthesize the conclusion that the seepage velocity increases. The more efficiently the temperature of the rock and soil mass is restored to the initial condition, the more efficiently the heat exchange performance of the buried pipe heat exchanger and the surrounding rock and soil mass is maintained, and the efficient operation of the ground source heat pump system in winter and summer is ensured.
引用
收藏
页数:11
相关论文
共 27 条
[1]   Thermal response tests on deep borehole heat exchangers with geothermal gradient [J].
Beier, Richard A. .
APPLIED THERMAL ENGINEERING, 2020, 178
[2]  
Dai L.H., 2001, Renew. Energy, V107, P617
[3]  
Deng N., 2014, J. Solar Energy, V35, P320
[4]  
Ding C.Y., 2019, Study on the effect of tracer on the RTD curve of tundish
[5]   A study on the performance of a geothermal heat exchanger under coupled heat conduction and groundwater advection [J].
Fan, Rui ;
Jiang, Yiqiang ;
Yao, Yang ;
Shiming, Deng ;
Ma, Zuiliang .
ENERGY, 2007, 32 (11) :2199-2209
[6]   An analysis of heat flow through a borehole heat exchanger validated model [J].
Florides, Georgios A. ;
Christodoulides, Paul ;
Pouloupatis, Panayiotis .
APPLIED ENERGY, 2012, 92 :523-533
[7]   An improved thermal response test for U-tube ground heat exchanger based on optical fiber thermometers [J].
Fujii, Hikari ;
Okubo, Hiroaki ;
Nishi, Keita ;
Itoi, Ryuichi ;
Ohyama, Kunio ;
Shibata, Kazuo .
GEOTHERMICS, 2009, 38 (04) :399-406
[8]  
Guo X., 2018, Measurement of groundwater seepage velocity and performance of tempcrature heating probes
[9]   Effective design and operation of hybrid ground-source heat pumps: Three case studies [J].
Hackel, Scott ;
Pertzborn, Amanda .
ENERGY AND BUILDINGS, 2011, 43 (12) :3497-3504
[10]  
Jia L.J., 2016, Technological Innovation and Productivity, V11, P117, DOI 10.3969/j.issn.1674-9146.2016.11.117