Rapid Method To Determine 137Cs, 237Np, and Pu Isotopes in Seawater by SF-ICP-MS

被引:8
作者
Zhang, Shuai [1 ,2 ]
Liu, Zhiyong [1 ,3 ,4 ]
Yang, Guosheng [1 ]
Zheng, Jian [1 ]
Pan, Shaoming [2 ]
Aono, Tatsuo [1 ,6 ]
Sakaguchi, Aya [5 ]
机构
[1] Natl Inst Quantum Sci & Technol, Inst Radiol Sci, Inage, Chiba 2638555, Japan
[2] Nanjing Univ, Sch Geog & Oceanog Sci, Nanjing 210023, Peoples R China
[3] Soochow Univ, Sch Radiol & Interdisciplinary Sci RAD X, State Key Lab Radiat Med & Protect, Suzhou 215123, Peoples R China
[4] Soochow Univ, Collaborat Innovat Ctr Radiat Med Jiangsu Higher E, Suzhou 215123, Peoples R China
[5] Univ Tsukuba, Inst Pure & Appl Sci, Tsukuba, Ibaraki 3058577, Japan
[6] Fukushima Inst Res Educ & Innovat, Radioecol Unit, Fukushima 9601295, Japan
关键词
ACCELERATOR MASS-SPECTROMETRY; SEA-WATER; ANTHROPOGENIC RADIONUCLIDES; MARINE-ENVIRONMENT; SEDIMENT SAMPLES; NP; PLUTONIUM; AM; ACID; PERFORMANCE;
D O I
10.1021/acs.analchem.3c02702
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Neptunium-237, owing to its long half-life (t(1/2) = 2.14 x 10(6) year) and similar conservatism to Cs-137, has the potential to replace Cs-137 for water mass circulation studies on decades and even longer time scales. A new method for the determination of Cs-137, Np-237, and Pu isotopes in seawater samples was proposed to solve the difficulty of Np-237 analysis in seawater. The developed method includes the separation technique of ammonium phosphomolybdate (AMP) adsorption for Cs-137 and anion exchange chromatography for Np-237 and Pu, a measurement technique of gamma spectrometry for Cs-137 and SF-ICP-MS for Np-237 and Pu isotopes. Pu-242 as a pseudo isotope dilution tracer for Np, the negligible chemical fractionation between Np-237 and Pu-242 of 1.02 +/- 0.06 (k = 2) was obtained by implementing sophisticated control of the redox system and chromatographic elution optimization. The analytical results for the International Atomic Energy Agency Certified Reference Materials (IAEA-443) agreed with the reference values, showing chemical yields of 65-88%, U decontamination factor above 10(6) level, and improved sample throughput (5 days for 12 samples). Meanwhile, the lower method detection limits (MDLs) of Np-237, Pu-239, and Pu-240 were 1.3 x 10(-3), 0.065, and 0.15 mu Bq L-1 for 15 L seawater, respectively. Results obtained by the developed method can be used to evaluate the impact on the marine ecological system of the planned marine discharge of Fukushima decontaminated wastewater. Working toward that purpose, we are the first to report the Np-237 activity concentration in Pacific Ocean seawater sampled near the station site, and we obtained the value of 0.122-0.154 mu Bq L-1.
引用
收藏
页码:16892 / 16901
页数:10
相关论文
共 56 条
  • [41] Rapid Multisample Analysis for Simultaneous Determination of Anthropogenic Radionuclides in Marine Environment
    Qiao, Jixin
    Shi, Keliang
    Hou, Xiaolin
    Nielsen, Sven
    Roos, Per
    [J]. ENVIRONMENTAL SCIENCE & TECHNOLOGY, 2014, 48 (07) : 3935 - 3942
  • [42] Sequential Injection Method for Rapid and Simultaneous Determination of 236U, 237Np, and Pu Isotopes in Seawater
    Qiao, Jixin
    Hou, Xiaolin
    Steier, Peter
    Golser, Robin
    [J]. ANALYTICAL CHEMISTRY, 2013, 85 (22) : 11026 - 11033
  • [43] High-Throughput Sequential Injection Method for Simultaneous Determination of Plutonium and Neptunium in Environmental Solids Using Macroporous Anion-Exchange Chromatography, Followed by Inductively Coupled Plasma Mass Spectrometric Detection
    Qiao, Jixin
    Hou, Xiaolin
    Roos, Per
    Miro, Manuel
    [J]. ANALYTICAL CHEMISTRY, 2011, 83 (01) : 374 - 381
  • [44] Rapid and simultaneous determination of neptunium and plutonium isotopes in environmental samples by extraction chromatography using sequential injection analysis and ICP-MS
    Qiao, Jixin
    Hou, Xiaolin
    Roos, Per
    Miro, Manuel
    [J]. JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 2010, 25 (11) : 1769 - 1779
  • [45] Accelerator Mass Spectrometry of Actinides in Ground- and Seawater: An Innovative Method Allowing for the Simultaneous Analysis of U, Np, Pu, Am, and Cm Isotopes below ppq Levels
    Quinto, Francesca
    Golser, Robin
    Lagos, Markus
    Plaschke, Markus
    Schaefer, Thorsten
    Steier, Peter
    Geckeis, Horst
    [J]. ANALYTICAL CHEMISTRY, 2015, 87 (11) : 5766 - 5773
  • [46] Incomplete fusion reaction producing Pa nuclides in the 232Th + 7Li reaction
    Teranishi, Kakeru
    Morita, Ryoga
    Hayakawa, Yuta
    Sakaguchi, Aya
    Nakajima, Akihisa
    Komori, Yukiko
    Yokokita, Takuya
    Mori, Daiki
    Haba, Hiromitsu
    Yokoyama, Akihiko
    [J]. RADIOCHIMICA ACTA, 2023, 111 (08) : 589 - 596
  • [47] Determination of 237Np in environmental and nuclear samples: A review of the analytical method
    Thakur, P.
    Mulholland, G. P.
    [J]. APPLIED RADIATION AND ISOTOPES, 2012, 70 (08) : 1747 - 1778
  • [48] Determination of Transuranium Isotopes (Pu, Np, Am) by Radiometric Techniques: A Review of Analytical Methodology
    Vajda, Nora
    Kim, Chang-Kyu
    [J]. ANALYTICAL CHEMISTRY, 2011, 83 (12) : 4688 - 4719
  • [49] High-Performance Method for Determination of Pu Isotopes in Soil and Sediment Samples by Sector Field-Inductively Coupled Plasma Mass Spectrometry
    Wang, Zhongtang
    Zheng, Jian
    Ni, Youyi
    Men, Wu
    Tagami, Keiko
    Uchida, Shigeo
    [J]. ANALYTICAL CHEMISTRY, 2017, 89 (04) : 2221 - 2226
  • [50] An overview of current knowledge concerning the inventory and sources of plutonium in the China Seas
    Wu, Junwen
    Sun, Jiang
    Xiao, Xiyu
    [J]. MARINE POLLUTION BULLETIN, 2020, 150