Development and validation of a UPLC-MS/MS method for simultaneous detection of doxorubicin and sorafenib in plasma: Application to pharmacokinetic studies in rats

被引:0
作者
Altalal, Alanoud [1 ]
Almomen, Aliyah [2 ,3 ]
Alkholief, Musaed [1 ,3 ]
Binkhathlan, Ziyad [1 ,3 ]
Alzoman, Nourah Z. [2 ]
Alshamsan, Aws [1 ]
机构
[1] King Saud Univ, Coll Pharm, Dept Pharmaceut, Riyadh 11495, Saudi Arabia
[2] King Saud Univ, Coll Pharm, Dept Pharmaceut Chem, Riyadh 11495, Saudi Arabia
[3] King Saud Univ, Coll Pharm, Nanobiotechnol Unit, Riyadh 11495, Saudi Arabia
关键词
Doxorubicin; Sorafenib; Co-administration; UPLC-MS; MS; Pharmacokinetics; ADVANCED HEPATOCELLULAR-CARCINOMA; RAF/MEK/ERK PATHWAY; P-GLYCOPROTEIN; ADRIAMYCIN; DISPOSITION; SENSITIVITY; MECHANISMS; RESISTANCE; TARGETS; SYSTEMS;
D O I
10.1016/j.jsps.2023.05.025
中图分类号
R9 [药学];
学科分类号
1007 ;
摘要
An ultra-performance liquid chromatography-tandem mass spectrometry (UPLC-MS/MS) was developed for the simultaneous quantitation of doxorubicin (DOX) and sorafenib (SOR) in rat plasma. Chromatographic separation was performed using a reversed-phase column C18 (1.7 lm, 1.0 x 100 mm Acquity UPLC BEHTM). The gradient mobile phase system consisted of water containing 0.1% acetic acid (mobile phase A) and methanol (mobile phase B) with a flow rate of 0.40 mL/min over 8 min. Erlotinib (ERL) was used as an internal standard (IS). The quantitation of conversion of [M + H]+, which was the protonated precursor ion, to the corresponding product ions was performed using multiple reaction monitoring (MRM) with a mass-to-charge ratio (m/z) of 544 > 397.005 for DOX, 465.05 > 252.03 for SOR, and 394 > 278 for the IS. Different parameters were used to validate the method including accuracy, precision, linearity, and stability. The developed UPLC-MS/MS method was linear over the concentration ranges of 9-2000 ng/mL and 7-2000 ng/mL with LLOQ of 9 and 7 ng/mL for DOX and SOR, respectively. The intraday and inter-day accuracy, expressed as % relative standard deviation (RSD%), was below 10% for both DOX and SOR in all QC samples that have drug concentrations above the LLOQ. The intra-day and inter-day precision, expressed as percent relative error (Er %), was within the limit of 15.0% for all concentrations above LLOQ. Four groups of Wistar rats (250-280 g) were used to conduct the pharmacokinetic study. Group I received a single intraperitoneal (IP) injection of DOX (5 mg/kg); Group II received a single oral dose of SOR (40 mg/kg), Group III received a combination of both drugs; and Group IV received sterile water for injection IP and 0.9% w/v sodium chloride solution orally to serve as a control. Noncompartmental analysis was used to calculate the different pharmacokinetic parameters. Data revealed that coadministration of DOX and SOR altered some of the pharmacokinetic parameters of both agents and resulted in an increase in the Cmax and AUC and reduction in the apparent clearance (CL/F). In conclusion, our newly developed method is sensitive, specific, and can reliably be used to simultaneously determine DOX and SOR concentrations in rat plasma. Moreover, the results of the pharmacokinetic study suggest that coadministration of DOX and SOR might cause an increase in exposure of both drugs. & COPY; 2023 The Authors. Published by Elsevier B.V. on behalf of King Saud University. This is an open access article under the CC BY-NC-ND license (http://creativecommons.org/licenses/by-nc-nd/4.0/).
引用
收藏
页码:1317 / 1326
页数:10
相关论文
共 50 条
  • [41] Bioanalytical method development and validation of corynantheidine, a kratom alkaloid, using UPLC-MS/MS, and its application preclinical pharmacokinetic studies
    King, Tamara, I
    Sharma, Abhisheak
    Kamble, Shyam H.
    Leon, Francisco
    Berthold, Erin C.
    Popa, Raluca
    Cerlati, Orelia
    Prentice, Boone M.
    McMahon, Lance R.
    McCurdy, Christopher R.
    Avery, Bonnie A.
    [J]. JOURNAL OF PHARMACEUTICAL AND BIOMEDICAL ANALYSIS, 2020, 180
  • [42] An UPLC-MS/MS method for the determination of EAI045 in plasma and tissues and its application to pharmacokinetic and distribution studies in rats
    Lv, Handeng
    Shen, Enzhao
    Luo, Lu
    Xu, Yong
    Pan, Yaqian
    Wu, Kaiqi
    Xing, Zhicheng
    Ye, Faqing
    Zhang, Yuan
    [J]. PHARMAZIE, 2018, 73 (11): : 630 - 634
  • [43] Pharmacokinetic and metabolic profiling studies of osmundacetone in rats by UPLC-MS/MS and UPLC-QE-Orbitrap-HRMS
    Wu, Hao
    Cao, Yijia
    Wang, Jiaqi
    Liu, Runhua
    Sun, Yu
    Zhang, Chenning
    Sun, Yikun
    [J]. BIOMEDICAL CHROMATOGRAPHY, 2022, 36 (01)
  • [44] Development and Validation of UPLC-MS/MS Method for Determination of Brexpiprazole in Rat Plasma
    Wu, Meng-yuan
    Wang, Bing-bing
    Xue, Hao
    Kang, Ya-fei
    Zhang, Yu-xin
    Qiu, Xiang-jun
    [J]. LATIN AMERICAN JOURNAL OF PHARMACY, 2020, 39 (08): : 1605 - 1610
  • [45] An UPLC-MS/MS method for the quantitation of vortioxetine in rat plasma: Application to a pharmacokinetic study
    Gu, Er-min
    Huang, Chengke
    Liang, Bingqing
    Yuan, Lingjing
    Lan, Tian
    Hu, Guoxin
    Zhou, Hongyu
    [J]. JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2015, 997 : 70 - 74
  • [46] UPLC-MS/MS Determination of Chlorogenic Acid, Hyperoside and Astragalin in Plasma and its Pharmacokinetic Application in Liver Injury Rats
    Zhang, Ying
    Xu, Shu-ya
    Jia, Zhe
    Han, Ting
    Liu, Meng-nan
    Jia, Tian-ying
    Qu, Wen-jia
    Xu, Xinfang
    Li, Xiang-ri
    [J]. CURRENT PHARMACEUTICAL ANALYSIS, 2021, 17 (08) : 1016 - 1025
  • [47] Pharmacokinetic Studies of Gypenoside XLVI in Rat Plasma using UPLC-MS/MS Method
    Li, Han
    Yang, Aiping
    Yang, Meng
    Zhou, Fengjuan
    Zhang, Rui
    Zheng, Zongping
    Wang, Xiachang
    [J]. CURRENT PHARMACEUTICAL ANALYSIS, 2024, 20 (02) : 143 - 151
  • [48] An UPLC-MS/MS Method for the Quantitation of Ledipasvir in Rat Plasma: Application to a Pharmacokinetic Study
    Zhang, Kun
    Ma, Xiang-qin
    Li, Zhi-hao
    Zhang, Yun-long
    Song, Ji-jun
    [J]. LATIN AMERICAN JOURNAL OF PHARMACY, 2016, 35 : 1116 - 1121
  • [49] Quantification of SHR0302 in human plasma by UPLC-MS/MS and application to a pharmacokinetic study
    Ding, Li-kun
    Chen, Yan
    Liu, Mei-you
    Gao, Xiao-hua
    Ren, Dan-jun
    Diao, Qing-bo
    Yang, Lin
    Wen, Ai-dong
    Wang, Jing-wen
    [J]. BIOMEDICAL CHROMATOGRAPHY, 2022, 36 (11)
  • [50] Simultaneous determination of etonogestrel and ethinyl estradiol in human plasma by UPLC-MS/MS and its pharmacokinetic study
    Nair, Sneha G.
    Patel, Daxesh P.
    Gonzalez, Frank J.
    Patel, Bhargav M.
    Singhal, Puran
    Chaudhary, Darshan V.
    [J]. BIOMEDICAL CHROMATOGRAPHY, 2018, 32 (05)