Role of carotid corrected flow time and peak velocity variation in predicting fluid responsiveness: a systematic review and meta-analysis

被引:14
作者
Singla, Deepak [1 ]
Gupta, Bhavna [1 ]
Varshney, Pragya [1 ]
Mangla, Mishu [2 ]
Walikar, Beeraling Ningappa [1 ]
Jamir, Tiajem [1 ]
机构
[1] All India Inst Med Sci, Dept Anesthesiol, Veerbhadra Rd, Rishikesh 249203, Uttaranchal, India
[2] All India Inst Med Sci, Dept Obstet & Gynecol, Hyderabad, Telangana, Pakistan
关键词
Cardiac output; Carotid arteries; Echocardiography; Fluid therapy; Hemody-namic monitoring; Ultrasonography; MECHANICALLY VENTILATED PATIENTS; BLOOD-FLOW; RESPIROPHASIC VARIATION; SHOCK;
D O I
10.4097/kja.22385
中图分类号
R614 [麻醉学];
学科分类号
100217 ;
摘要
Background: Dynamic parameters used for predicting fluid responsiveness require special equipment and are minimally invasive. Therefore, recent interest in the use of carotid ar-tery ultrasound parameters, such as carotid corrected flow time (FTc) and peak velocity variation (Delta Vpeak) has grown. Therefore, we performed this systematic review and me-ta-analysis to assess the ability of carotid FTc and/or Delta Vpeak to accurately predict fluid re-sponsiveness.Methods: We searched the PubMed and Embase databases for articles evaluating the diag-nostic accuracy of carotid FTc or Delta Vpeak for predicting fluid responsiveness. Two inde-pendent authors performed the search and selected studies published until May 2022. The studies were assessed for the inclusion and exclusion criteria using Rayyan (Rayyan Sys-tems Inc., 2022).Results: Ten studies (n = 438) that fulfilled the inclusion criteria were selected. Studies were divided into those assessing carotid FTc and those assessing carotid Delta Vpeak. Five studies (six datasets) assessed FTc. The pooled sensitivity and specificity of carotid FTc were 0.76 and 0.88, respectively. The summary receiver operating characteristic (SROC) curve for carotid FTc had an area under the curve (AUC) of 0.9092, with a Q value of 0.8412. Seven studies calculated carotid Delta Vpeak. The pooled sensitivity and specificity for Delta Vpeak were 0.83 and 0.81, respectively. The SROC curve had an AUC of 0.8941 and a Q value of 0.8250.Conclusions: Our meta-analysis showed that both carotid FTc and Delta Vpeak are useful for predicting fluid responsiveness in anesthesia and critical care settings with good specificity and sensitivity.
引用
收藏
页码:183 / 193
页数:11
相关论文
共 50 条
  • [21] Comparison of the carotid corrected flow time and tidal volume challenge for assessing fluid responsiveness in robot-assisted laparoscopic surgery
    Tang, Xixi
    Chen, Qi
    Huang, Zejun
    Liang, Jingqiu
    An, Ran
    Liu, Hongliang
    JOURNAL OF ROBOTIC SURGERY, 2023, 17 (06) : 2763 - 2772
  • [22] Predicting Fluid Responsiveness Using Carotid Ultrasound in Mechanically Ventilated Patients: A Systematic Review and Meta-Analysis of Diagnostic Test Accuracy Studies
    Lipszyc, Adam C.
    Walker, Samuel C. D.
    Beech, Alexander P.
    Wilding, Helen
    Akhlaghi, Hamed
    ANESTHESIA AND ANALGESIA, 2024, 138 (06) : 1174 - 1186
  • [23] What is the impact of the fluid challenge technique on diagnosis of fluid responsiveness? A systematic review and meta-analysis
    Toscani, Laura
    Aya, Hollmann D.
    Antonakaki, Dimitra
    Bastoni, Davide
    Watson, Ximena
    Arulkumaran, Nish
    Rhodes, Andrew
    Cecconi, Maurizio
    CRITICAL CARE, 2017, 21
  • [24] Variables influencing the prediction of fluid responsiveness: a systematic review and meta-analysis
    Sanchez, Jorge Ivan Alvarado
    Ruiz, Juan Daniel Caicedo
    Fernandez, Juan Jose Diaztagle
    Martinez, Luis Eduardo Cruz
    Hernandez, Fredy Leonardo Carreno
    Herrera, Carlos Andres Santacruz
    Ospina-Tascon, Gustavo Adolfo
    CRITICAL CARE, 2023, 27 (01)
  • [25] The effect of carotid revascularization on the ophthalmic artery flow: systematic review and meta-analysis
    Nana, Petroula
    Spanos, Konstantinos
    Antoniou, George
    Kouvelos, George
    Vasileiou, Vasiliki
    Tsironi, Evangelia
    Giannoukas, Athanasios
    INTERNATIONAL ANGIOLOGY, 2021, 40 (01) : 23 - 28
  • [26] VALUE OF CORRECTED FLOW TIME IN COMMON CAROTID ARTERY IN PREDICTING VOLUME RESPONSIVENESS UNDER MECHANICAL VENTILATION
    Wang, Hongzhi
    Chen, Wei
    Cheng, Hao
    Liu, Can
    Yao, WeiDong
    Ding, Fang
    Wang, YuLong
    Chen, Yongquan
    SHOCK, 2022, 58 (01): : 28 - 33
  • [27] Correlation of carotid corrected flow time and respirophasic variation in blood flow peak velocity with stroke volume variation in elderly patients under general anaesthesia
    Yu Chen
    Ziyou Liu
    Jun Fang
    Yanhu Xie
    Min Zhang
    Jia Yang
    BMC Anesthesiology, 22
  • [28] Accuracy of indices of inferior vena cava in predicting fluid responsiveness in patients with shock: A systematic review and meta-analysis
    Yang, Wenwen
    Xu, Ping
    Dong, Yue
    Lu, Xuan
    INTENSIVE AND CRITICAL CARE NURSING, 2025, 89
  • [29] Carotid Atherosclerosis in Predicting Coronary Artery Disease A Systematic Review and Meta-Analysis
    Bytyci, Ibadete
    Shenouda, Rafik
    Wester, Per
    Henein, Michael Y.
    ARTERIOSCLEROSIS THROMBOSIS AND VASCULAR BIOLOGY, 2021, 41 (04) : e224 - e237
  • [30] Respirophasic carotid artery peak velocity variation as a predictor of fluid responsiveness in mechanically ventilated patients with coronary artery disease
    Song, Y.
    Kwak, Y. L.
    Song, J. W.
    Kiml, Y. J.
    Shim, J. K.
    BRITISH JOURNAL OF ANAESTHESIA, 2014, 113 (01) : 61 - 66