Thermal and energy performance evaluation of a full-scale test cabin equipped with PCM embedded radiant chilled ceiling

被引:12
|
作者
Mousavi, Seyedmostafa [1 ]
Rismanchi, Behzad [1 ]
Brey, Stefan [2 ]
Aye, Lu [1 ]
机构
[1] Univ Melbourne, Fac Engn & Informat Technol, Dept Infrastructure Engn, Renewable Energy & Energy Efficiency Grp, Melbourne, Vic 3010, Australia
[2] Invaus Pty Ltd, Melbourne, Vic 3000, Australia
关键词
Phase change material (PCM); Radiant cooling; Ceiling panel; Thermal comfort; Energy flexibility; Experiment;
D O I
10.1016/j.buildenv.2023.110348
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
The escalating global demand for space cooling has led to the emergence of new cooling technologies, including the phase change material embedded radiant chilled ceiling (PCM-RCC) system. This technology improves en-ergy efficiency and indoor environmental quality, while also offering demand-side flexibility. The present study experimentally evaluates the thermal efficiency and energy performance of a PCM-RCC system in a full-scale test cabin equipped with PCM panels. Here, the transient thermal behaviour of PCM ceiling panels besides the cooling energy delivered during charging-discharging cycles are examined. The indoor thermal comfort and peak electricity demand reduction enabled by the present PCM-RCC are also discussed. The results reveal that chilled water circulation for 4-5 h overnight was sufficient to fully recharge the PCM panels. Over 80% of the occupancy time was classified as "Class B '' thermal comfort according to ISO 7730. The system's daily electricity usage was mostly concentrated during off-peak hours, accounting for similar to 70% of the total usage. While the controlling schedule used in this study responded to the transient thermal behaviour of the indoor space and PCM ceiling panels, a more dynamic, predictive schedule is necessary to improve the system's overall efficiency and further enhance indoor thermal comfort in response to the changing environmental conditions.
引用
收藏
页数:13
相关论文
共 32 条
  • [21] Thermal performance of a full-scale pre-tensioned high strength concrete (PHC) energy pile
    Guo, Yachen
    Wang, Chenglong
    Bouazza, Abdelmalek
    Chang, Honglin
    Kong, Gangqiang
    JOURNAL OF ENERGY STORAGE, 2024, 98
  • [22] Wall-embedded micro heat pump for radiant heating in buildings: Evaluation of energy and thermal comfort performance
    Wu, Feng
    Alkandari, Sarah
    Ma, Jie
    Dhillon, Parveen
    Liu, Haotian
    Braun, James E.
    Karava, Panagiota
    Ziviani, Davide
    Horton, W. Travis
    ENERGY AND BUILDINGS, 2024, 310
  • [23] Performance Evaluation of a Full-Scale Fused Magnesia Furnace for MgO Production Based on Energy and Exergy Analysis
    Jiang, Tianchi
    Zhang, Weijun
    Liu, Shi
    ENERGIES, 2022, 15 (01)
  • [24] Seismic performance evaluation and full-scale shaking table test of timber frame, conventional construction and composite structure
    Nakagawa, Manabu
    Isoda, Hiroshi
    Okano, Akitaka
    Journal of Structural and Construction Engineering, 2009, 74 (636): : 321 - 330
  • [25] Performance and Thermal Stress Evaluation of Full-Scale SOEC Stack Using Multi-Physics Modeling Method
    Wang, Hao
    Xiao, Liusheng
    Liu, Yingqi
    Zhang, Xueping
    Zhou, Ruidong
    Liu, Fangzheng
    Yuan, Jinliang
    ENERGIES, 2023, 16 (23)
  • [26] Full-scale evaluation of FFU configurations in an optical cleanroom injection molding for improving thermal performance and contaminant removal
    Permana, Indra
    Agharid, Alya Penta
    Singh, Nitesh
    Wang, Fujen
    CASE STUDIES IN THERMAL ENGINEERING, 2024, 61
  • [27] Experimental performance of a full-scale solar thermal system designed to meet residential heating demands with passive solar energy
    Brown, Sarah
    Beausoleil-Morrison, Ian
    SOLAR ENERGY, 2023, 264
  • [28] Seismic performance evaluation of water supply pipes installed in a full-scale RC frame structure based on a shaking table test
    Houli Wu
    Endong Guo
    Jingyi Wang
    Xin Dai
    Chenxi Dai
    Earthquake Engineering and Engineering Vibration, 2024, 23 : 163 - 178
  • [29] Seismic performance evaluation of water supply pipes installed in a full-scale RC frame structure based on a shaking table test
    Wu Houli
    Guo Endong
    Wang Jingyi
    Dai Xin
    Dai Chenxi
    Earthquake Engineering and Engineering Vibration, 2024, 23 (01) : 163 - 178
  • [30] Seismic performance evaluation of water supply pipes installed in a full-scale RC frame structure based on a shaking table test
    Wu, Houli
    Guo, Endong
    Wang, Jingyi
    Dai, Xin
    Dai, Chenxi
    EARTHQUAKE ENGINEERING AND ENGINEERING VIBRATION, 2024, 23 (01) : 163 - 178