Silver Ion High-Performance Liquid Chromatography-Atmospheric Pressure Chemical Ionization Mass Spectrometry: A Tool for Analyzing Cuticular Hydrocarbons

被引:2
作者
Vrkoslav, Vladimir [1 ]
Horka, Petra [1 ,2 ]
Jindrich, Jindrich [3 ]
Budesinsky, Milos [1 ]
Cvacka, Josef [1 ,2 ]
机构
[1] Czech Acad Sci, Inst Organ Chem & Biochem, Flemingovo Namesti 542-2, Prague 16000, Czech Republic
[2] Charles Univ Prague, Fac Sci, Dept Analyt Chem, Hlavova 2030-8, Prague 12800, Czech Republic
[3] Charles Univ Prague, Fac Sci, Dept Organ Chem, Hlavova 2030-8, Prague 12800, Czech Republic
关键词
double bonds; hydrocarbons; mass spectrometry; Neobellieria bullata; Periplaneta americana; semiochemicals; ACID METHYL-ESTERS; TEMPERATURE GAS-CHROMATOGRAPHY; LASER-DESORPTION IONIZATION; FATTY-ACID; SATURATED-HYDROCARBONS; FIELD-IONIZATION; LIPIDS; SEPARATION; PHASE; HPLC;
D O I
10.3390/molecules28093794
中图分类号
Q5 [生物化学]; Q7 [分子生物学];
学科分类号
071010 ; 081704 ;
摘要
Aliphatic hydrocarbons (HCs) are usually analyzed by gas chromatography (GC) or matrix-assisted laser desorption/ionization (MALDI) mass spectrometry. However, analyzing long-chain HCs by GC is difficult because of their low volatility and the risk of decomposition at high temperatures. MALDI cannot distinguish between isomeric HCs. An alternative approach based on silver ion high-performance liquid chromatography (Ag-HPLC) is shown here. The separation of HC standards and cuticular HCs was accomplished using two ChromSpher Lipids columns connected in series. A gradient elution of the analytes was optimized using mobile phases prepared from hexane (or isooctane) and acetonitrile, 2-propanol, or toluene. HCs were detected by atmospheric pressure chemical ionization mass spectrometry (APCI-MS). Good separation of the analytes according to the number of double bonds, cis/trans geometry, and position of double bonds was achieved. The retention times increased with the number of double bonds, and trans isomers eluted ahead of cis isomers. The mobile phase significantly affected the mass spectra of HCs. Depending on the mobile phase composition, deprotonated molecules, molecular ions, protonated molecules, and various solvent-related adducts of HCs were observed. The optimized Ag-HPLC/APCI-MS was applied for characterizing cuticular HCs from a flesh fly, Neobellieria bullata, and cockroach, Periplaneta americana. The method made it possible to detect a significantly higher number of HCs than previously reported for GC or MALDI-MS. Unsaturated HCs were frequently detected as isomers differing by double-bond position(s). Minor HCs with trans double bonds were found beside the prevailing cis isomers. Ag-HPLC/APCI-MS has great potential to become a new tool in chemical ecology for studying cuticular HCs.
引用
收藏
页数:17
相关论文
共 66 条
[31]   High-performance liquid chromatography in group-type separation and technical or process analytics of petroleum products [J].
Kaminski, M ;
Kartanowicz, R ;
Gilgenast, E ;
Namiesnik, J .
CRITICAL REVIEWS IN ANALYTICAL CHEMISTRY, 2005, 35 (03) :193-216
[32]   Improved Abundance Sensitivity of Molecular Ions in Positive-Ion APCI MS Analysis of Petroleum in Toluene [J].
Kim, Young Hwan ;
Kim, Sunghwan .
JOURNAL OF THE AMERICAN SOCIETY FOR MASS SPECTROMETRY, 2010, 21 (03) :386-392
[33]   Biosynthesis and secretion of plant cuticular wax [J].
Kunst, L ;
Samuels, AL .
PROGRESS IN LIPID RESEARCH, 2003, 42 (01) :51-80
[34]   SILVER LOADED ALUMINOSILICATE AS A STATIONARY PHASE FOR LIQUID-CHROMATOGRAPHIC SEPARATION OF UNSATURATED-COMPOUNDS [J].
LAM, S ;
GRUSHKA, E .
JOURNAL OF CHROMATOGRAPHIC SCIENCE, 1977, 15 (07) :234-238
[35]   Characterization of fatty acid and triacylglycerol composition in animal fats using silver-ion and non-aqueous reversed-phase high-performance liquid chromatography/mass spectrometry and gas chromatography/flame ionization detection [J].
Lisa, Miroslav ;
Netusilova, Katerina ;
Franek, Lukas ;
Dvorakova, Hana ;
Vrkoslav, Vladimir ;
Holcapek, Michal .
JOURNAL OF CHROMATOGRAPHY A, 2011, 1218 (42) :7499-7510
[36]   Regioisomeric Characterization of Triacylglycerols Using Silver-Ion HPLC/MS and Randomization Synthesis of Standards [J].
Lisa, Miroslav ;
Velinska, Hana ;
Holcapek, Michal .
ANALYTICAL CHEMISTRY, 2009, 81 (10) :3903-3910
[37]   The detection of high-mass aliphatics in petroleum by matrix-assisted laser desorption/ionisation mass spectrometry [J].
Lorente, Esther ;
Berrueco, Cesar ;
Herod, Alan A. ;
Millan, Marcos ;
Kandiyoti, Rafael .
RAPID COMMUNICATIONS IN MASS SPECTROMETRY, 2012, 26 (14) :1581-1590
[38]  
Ludányi K, 1999, J MASS SPECTROM, V34, P264, DOI 10.1002/(SICI)1096-9888(199904)34:4<264::AID-JMS749>3.3.CO
[39]  
2-H
[40]   Fragmentation of Saturated Hydrocarbons upon Atmospheric Pressure Chemical Ionization Is Caused by Proton-Transfer Reactions [J].
Manheim, Jeremy M. ;
Milton, Jacob R. ;
Zhang, Y. ;
Kenttamaa, Hilkka, I .
ANALYTICAL CHEMISTRY, 2020, 92 (13) :8883-8892