Silver Ion High-Performance Liquid Chromatography-Atmospheric Pressure Chemical Ionization Mass Spectrometry: A Tool for Analyzing Cuticular Hydrocarbons

被引:2
作者
Vrkoslav, Vladimir [1 ]
Horka, Petra [1 ,2 ]
Jindrich, Jindrich [3 ]
Budesinsky, Milos [1 ]
Cvacka, Josef [1 ,2 ]
机构
[1] Czech Acad Sci, Inst Organ Chem & Biochem, Flemingovo Namesti 542-2, Prague 16000, Czech Republic
[2] Charles Univ Prague, Fac Sci, Dept Analyt Chem, Hlavova 2030-8, Prague 12800, Czech Republic
[3] Charles Univ Prague, Fac Sci, Dept Organ Chem, Hlavova 2030-8, Prague 12800, Czech Republic
关键词
double bonds; hydrocarbons; mass spectrometry; Neobellieria bullata; Periplaneta americana; semiochemicals; ACID METHYL-ESTERS; TEMPERATURE GAS-CHROMATOGRAPHY; LASER-DESORPTION IONIZATION; FATTY-ACID; SATURATED-HYDROCARBONS; FIELD-IONIZATION; LIPIDS; SEPARATION; PHASE; HPLC;
D O I
10.3390/molecules28093794
中图分类号
Q5 [生物化学]; Q7 [分子生物学];
学科分类号
071010 ; 081704 ;
摘要
Aliphatic hydrocarbons (HCs) are usually analyzed by gas chromatography (GC) or matrix-assisted laser desorption/ionization (MALDI) mass spectrometry. However, analyzing long-chain HCs by GC is difficult because of their low volatility and the risk of decomposition at high temperatures. MALDI cannot distinguish between isomeric HCs. An alternative approach based on silver ion high-performance liquid chromatography (Ag-HPLC) is shown here. The separation of HC standards and cuticular HCs was accomplished using two ChromSpher Lipids columns connected in series. A gradient elution of the analytes was optimized using mobile phases prepared from hexane (or isooctane) and acetonitrile, 2-propanol, or toluene. HCs were detected by atmospheric pressure chemical ionization mass spectrometry (APCI-MS). Good separation of the analytes according to the number of double bonds, cis/trans geometry, and position of double bonds was achieved. The retention times increased with the number of double bonds, and trans isomers eluted ahead of cis isomers. The mobile phase significantly affected the mass spectra of HCs. Depending on the mobile phase composition, deprotonated molecules, molecular ions, protonated molecules, and various solvent-related adducts of HCs were observed. The optimized Ag-HPLC/APCI-MS was applied for characterizing cuticular HCs from a flesh fly, Neobellieria bullata, and cockroach, Periplaneta americana. The method made it possible to detect a significantly higher number of HCs than previously reported for GC or MALDI-MS. Unsaturated HCs were frequently detected as isomers differing by double-bond position(s). Minor HCs with trans double bonds were found beside the prevailing cis isomers. Ag-HPLC/APCI-MS has great potential to become a new tool in chemical ecology for studying cuticular HCs.
引用
收藏
页数:17
相关论文
共 66 条
[1]   Analysis of triacylglycerol and fatty acid isomers by low-temperature silver-ion high performance liquid chromatography with acetonitrile in hexane as solvent: Limitations of the methodology [J].
Adlof, R. .
JOURNAL OF CHROMATOGRAPHY A, 2007, 1148 (02) :256-259
[2]   Analysis of triglyceride isomers by silver-ion high-performance liquid chromatography - Effect of column temperature on retention times [J].
Adlof, R ;
List, G .
JOURNAL OF CHROMATOGRAPHY A, 2004, 1046 (1-2) :109-113
[3]   SEPARATION OF CIS AND TRANS UNSATURATED FATTY-ACID METHYL-ESTERS BY SILVER ION HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHY [J].
ADLOF, RO .
JOURNAL OF CHROMATOGRAPHY A, 1994, 659 (01) :95-99
[4]   Measurement and optimization of organic chemical reaction yields by GC-MS with supersonic molecular beams [J].
Amirav, Aviv ;
Gordin, Alexander ;
Hagooly, Youlia ;
Rozen, Shlomo ;
Belgorodsky, Bogdan ;
Seemann, Boaz ;
Marom, Hanit ;
Gozin, Michael ;
Fialkov, Alexander B. .
TETRAHEDRON, 2012, 68 (29) :5793-5799
[5]   DEVELOPMENTAL-STUDY OF CUTICULAR HYDROCARBONS OF SARCOPHAGA-BULLATA [J].
ARMOLD, MT ;
REGNIER, FE .
JOURNAL OF INSECT PHYSIOLOGY, 1975, 21 (11) :1827-1833
[6]   TRANSFER-MATRIX APPROACH TO ESTIMATING COVERAGE DISCONTINUITIES AND MULTICRITICAL-POINT POSITIONS IN TWO-DIMENSIONAL LATTICE-GAS PHASE-DIAGRAMS [J].
BARTELT, NC ;
EINSTEIN, TL ;
ROELOFS, LD .
PHYSICAL REVIEW B, 1986, 34 (03) :1616-1623
[7]   INDIRECT PHOTOMETRIC DETECTION OF STRAIGHT CHAIN HYDROCARBONS SEPARATED BY REVERSE PHASE HPLC [J].
BENSON, GA ;
LENNON, M .
JOURNAL OF HIGH RESOLUTION CHROMATOGRAPHY & CHROMATOGRAPHY COMMUNICATIONS, 1987, 10 (02) :109-110
[8]  
Blomquist GJ, 2010, INSECT HYDROCARBONS: BIOLOGY, BIOCHEMISTRY, AND CHEMICAL ECOLOGY, P1, DOI 10.1017/CBO9780511711909
[9]   Analysis of saturated hydrocarbons by using chemical ionization combined with laser-induced acoustic desorption/Fourier transform ion cyclotron resonance mass spectrometry [J].
Campbell, JL ;
Crawford, KE ;
Kenttämaa, HI .
ANALYTICAL CHEMISTRY, 2004, 76 (04) :959-963
[10]   Laser desorption ionization and MALDI time-of-flight mass spectrometry for low molecular mass polyethylene analysis [J].
Chen, R ;
Yalcin, T ;
Wallace, WE ;
Guttman, CM ;
Li, L .
JOURNAL OF THE AMERICAN SOCIETY FOR MASS SPECTROMETRY, 2001, 12 (11) :1186-1192