A varying-swirl design concept for dry powder inhalers

被引:5
|
作者
Chaugule, Vishal [1 ]
dos Reis, Larissa Gomes [2 ]
Fletcher, David F. [3 ]
Young, Paul M. [2 ,4 ]
Traini, Daniela [2 ,5 ]
Soria, Julio [1 ]
机构
[1] Monash Univ, Dept Mech & Aerosp Engn, Lab Turbulence Res Aerosp & Combust LTRAC, Clayton Campus, Melbourne, Australia
[2] Woolcock Inst Med Res, Resp Technol, Sydney, Australia
[3] Univ Sydney, Sch Chem & Biomol Engn, Sydney, Australia
[4] Macquarie Univ, Macquarie Business Sch, Dept Mkt, Macquarie Pk, Australia
[5] Macquarie Univ, Fac Med, Macquarie Med Sch, Dept Biol Sci, Macquarie Pk, Australia
基金
澳大利亚研究理事会; 英国医学研究理事会;
关键词
Dry powder inhaler; Swirling flow; in-vitro deposition; Particle image velocimetry; Computational fluid dynamics; Particle tracking; COMPUTATIONAL FLUID-DYNAMICS; AERODYNAMIC PERFORMANCE; RESPIRATORY-TRACT; DEVICE DESIGN; INHALATION; DEPOSITION; MECHANISMS; GENERATION; EMISSION; MOTION;
D O I
10.1016/j.jaerosci.2023.106162
中图分类号
TQ [化学工业];
学科分类号
0817 ;
摘要
The de-agglomeration potential of a dry powder inhaler (DPI) strongly affects its aerosol performance. Typically, a swirling flow is employed for the entrainment and de-agglomeration of drug powder into the inhalation air flow. Here, we propose a novel design concept that passively modifies the DPI swirling-flow, and thereby the de-agglomeration process, in order to achieve higher lung deposition. The essence of this design is a varying inner cross-section of the pipe-shaped device, realised in the form of converging and diverging circular sections placed after the tangential inlets in the device. An improved aerosol performance was shown for this device, with the fine particle fraction reaching 68.4% of the emitted dose, compared with 66.8% from that of the baseline device. This was found to be a direct effect of the modified flow characteristics generated within the device and thereafter emerging from its mouthpiece. These flow characteristics were determined from computational fluid dynamics simulations and particle image velocimetry measurements.Adaptations of this DPI design concept were achieved through the use of a honeycomb grid placed either after the device tangential inlets, or at the device mouthpiece exit. When placed after the inlets, a 10.4% reduction in the fine particle fraction was observed, as the air flow was straightened due to the influence of the grid which significantly reduced the flow-swirl before the flow entered the converging-diverging sections. Whereas, when placed at the mouthpiece exit, the flow-straightening effect of the grid resulted in reduced lateral spreading of the emitted aerosol but did not significantly affect throat deposition.
引用
收藏
页数:17
相关论文
共 50 条
  • [21] Dry powder inhalers and the risk of error
    Terzano, Claudio
    RESPIRATION, 2008, 75 (01) : 14 - 15
  • [22] EFFECTIVENESS AND ACCEPTANCE OF DRY POWDER INHALERS
    KOHLER, D
    DEUTSCHE MEDIZINISCHE WOCHENSCHRIFT, 1995, 120 (41) : 1401 - 1404
  • [23] Formation of particles for dry powder inhalers
    Gradon, Leon
    Sosnowski, Tomasz R.
    ADVANCED POWDER TECHNOLOGY, 2014, 25 (01) : 43 - 55
  • [24] DRY POWDER INHALERS - ADVANTAGES AND LIMITATIONS
    CROMPTON, GK
    JOURNAL OF AEROSOL MEDICINE-DEPOSITION CLEARANCE AND EFFECTS IN THE LUNG, 1991, 4 (03): : 151 - 156
  • [25] Dry powder inhalers: A patent review
    Wang, Jiawei
    Kong, Xiangjun
    Hu, Linfeng
    Hu, Yuanjia
    JOURNAL OF DRUG DELIVERY SCIENCE AND TECHNOLOGY, 2022, 74
  • [26] Dry powder inhalers are environmentally preferable to metered-dose inhalers
    Wintemute, Kimberly
    Miller, Fiona
    CANADIAN MEDICAL ASSOCIATION JOURNAL, 2020, 192 (29) : E846 - E846
  • [27] Advancements in the Design and Development of Dry Powder Inhalers and Potential Implications for Generic Development
    Mohan, Abhinav Ram
    Wang, Qiang
    Dhapare, Sneha
    Bielski, Elizabeth
    Kaviratna, Anubhav
    Han, Liangfeng
    Boc, Susan
    Newman, Bryan
    PHARMACEUTICS, 2022, 14 (11)
  • [28] DESIGN CONSTRAINTS IMPACTING DEVELOPMENT OF INHALED ANTIBIOTICS IN PORTABLE DRY POWDER INHALERS
    Weers, Jeffry
    JOURNAL OF AEROSOL MEDICINE AND PULMONARY DRUG DELIVERY, 2014, 27 (04) : A18 - A18
  • [29] Dry powder inhalers - between the doctor and the patient
    Emeryk, Andrzej
    Pirozynski, Michal
    Emeryk-Maksymiuk, Justyna
    ADVANCES IN RESPIRATORY MEDICINE, 2018, 86 (01) : 44 - 52
  • [30] Dry Powder Inhalers for Delivery of Synthetic Biomolecules
    Omidian, Hossein
    Nokhodchi, Ali
    Babanejad, Niloofar
    PHARMACEUTICALS, 2025, 18 (02)