A varying-swirl design concept for dry powder inhalers

被引:5
|
作者
Chaugule, Vishal [1 ]
dos Reis, Larissa Gomes [2 ]
Fletcher, David F. [3 ]
Young, Paul M. [2 ,4 ]
Traini, Daniela [2 ,5 ]
Soria, Julio [1 ]
机构
[1] Monash Univ, Dept Mech & Aerosp Engn, Lab Turbulence Res Aerosp & Combust LTRAC, Clayton Campus, Melbourne, Australia
[2] Woolcock Inst Med Res, Resp Technol, Sydney, Australia
[3] Univ Sydney, Sch Chem & Biomol Engn, Sydney, Australia
[4] Macquarie Univ, Macquarie Business Sch, Dept Mkt, Macquarie Pk, Australia
[5] Macquarie Univ, Fac Med, Macquarie Med Sch, Dept Biol Sci, Macquarie Pk, Australia
基金
澳大利亚研究理事会; 英国医学研究理事会;
关键词
Dry powder inhaler; Swirling flow; in-vitro deposition; Particle image velocimetry; Computational fluid dynamics; Particle tracking; COMPUTATIONAL FLUID-DYNAMICS; AERODYNAMIC PERFORMANCE; RESPIRATORY-TRACT; DEVICE DESIGN; INHALATION; DEPOSITION; MECHANISMS; GENERATION; EMISSION; MOTION;
D O I
10.1016/j.jaerosci.2023.106162
中图分类号
TQ [化学工业];
学科分类号
0817 ;
摘要
The de-agglomeration potential of a dry powder inhaler (DPI) strongly affects its aerosol performance. Typically, a swirling flow is employed for the entrainment and de-agglomeration of drug powder into the inhalation air flow. Here, we propose a novel design concept that passively modifies the DPI swirling-flow, and thereby the de-agglomeration process, in order to achieve higher lung deposition. The essence of this design is a varying inner cross-section of the pipe-shaped device, realised in the form of converging and diverging circular sections placed after the tangential inlets in the device. An improved aerosol performance was shown for this device, with the fine particle fraction reaching 68.4% of the emitted dose, compared with 66.8% from that of the baseline device. This was found to be a direct effect of the modified flow characteristics generated within the device and thereafter emerging from its mouthpiece. These flow characteristics were determined from computational fluid dynamics simulations and particle image velocimetry measurements.Adaptations of this DPI design concept were achieved through the use of a honeycomb grid placed either after the device tangential inlets, or at the device mouthpiece exit. When placed after the inlets, a 10.4% reduction in the fine particle fraction was observed, as the air flow was straightened due to the influence of the grid which significantly reduced the flow-swirl before the flow entered the converging-diverging sections. Whereas, when placed at the mouthpiece exit, the flow-straightening effect of the grid resulted in reduced lateral spreading of the emitted aerosol but did not significantly affect throat deposition.
引用
收藏
页数:17
相关论文
共 50 条
  • [1] A counter-swirl design concept for dry powder inhalers
    Chaugule, Vishal
    dos Reis, Larissa Gomes
    Fletcher, David F.
    Young, Paul M.
    Traini, Daniela
    Soria, Julio
    INTERNATIONAL JOURNAL OF PHARMACEUTICS, 2024, 650
  • [2] A new add-on spacer design concept for dry-powder inhalers
    Matida, EA
    Finlay, WH
    Rimkus, A
    Grgic, B
    Lange, CF
    JOURNAL OF AEROSOL SCIENCE, 2004, 35 (07) : 823 - 833
  • [3] A new add-on spacer design concept for dry-powder inhalers
    Finlay, W.H. (warren.finlay@ualberta.ca), 1600, Elsevier Ltd (35):
  • [4] Detailed evaluation of drug powder deposition in swirl-type dry powder inhalers
    Sommerfeld, M.
    POWDER TECHNOLOGY, 2022, 407
  • [5] A method for the aerodynamic design of dry powder inhalers
    Ertunc, Oe
    Koeksoy, C.
    Wachtel, H.
    Delgado, A.
    INTERNATIONAL JOURNAL OF PHARMACEUTICS, 2011, 416 (01) : 25 - 34
  • [6] Dry powder inhalers and the right things to remember: a concept review
    Dal Negro, Roberto W.
    MULTIDISCIPLINARY RESPIRATORY MEDICINE, 2015, 10
  • [7] Concept review of dry powder inhalers: correct interpretation of published data
    Price, David
    Chrystyn, Henry
    MULTIDISCIPLINARY RESPIRATORY MEDICINE, 2015, 10
  • [8] Review of dry powder inhalers
    Prime, D
    Atkins, PJ
    Slater, A
    Sumby, B
    ADVANCED DRUG DELIVERY REVIEWS, 1997, 26 (01) : 51 - 58
  • [9] Review of dry powder inhalers
    Glaxo Wellcome R. and D., Park Road, Ware, United Kingdom
    不详
    ADV. DRUG DELIV. REV., 1 (51-58):
  • [10] Dry powder inhalers -: a review
    Kohlhäufl, M
    Haidl, P
    Voshaar, T
    Häussinger, K
    Köhler, D
    DEUTSCHE MEDIZINISCHE WOCHENSCHRIFT, 2004, 129 (39) : 2048 - 2052