Effect of the volume of resected discoid lateral meniscus on the contact stress of the tibiofemoral joint: A finite element analysis

被引:5
|
作者
Yokoe, Takuji [1 ]
Ouchi, Koki [1 ]
Matsumoto, Taisei [1 ]
Tajima, Takuya [1 ]
Chosa, Etsuo [1 ]
机构
[1] Univ Miyazaki, Fac Med, Dept Med Sensory & Motor Organs, Div Orthopaed Surg, Miyazaki 8891692, Japan
关键词
Discoid meniscus; Meniscectomy; Contact stress; Tibiofemoral joint; Finite element analysis; TIBIAL ARTICULAR-CARTILAGE; OSTEOCHONDRITIS-DISSECANS; FEMORAL CONDYLE; ARTHROSCOPIC TREATMENT; PARTIAL MENISCECTOMY; CHILDREN;
D O I
10.1016/j.knee.2023.02.013
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Background: Partial meniscectomy is commonly performed for symptomatic patients with discoid lateral meniscus (DLM) if conservative treatment fails. However, the development of knee osteoarthritis and osteochondral lesion are detrimental postoperative complica-tions. This study aimed to evaluate the effect of the volume of resected DLM on the contact stress of the tibiofemoral joint using a finite element analysis.Methods: Subject-specific finite-element models of the knee joint of a patient with DLM were developed from computed tomographic and magnetic resonance images. To evaluate the effect of partial meniscectomy on the contact stress in the lateral tibiofemoral joint, six knee models were created in the study (the native DLM, and five partially meniscectomized DLMs (according to the preserved width of the meniscus: 12 mm, 10 mm, 8 mm, 6 mm, and 4 mm)).Results: As the volume of resected DLM increased, higher contact stress was applied to the lateral tibiofemoral joint. Greater contact stress was applied to the preserved lateral menis-cus than to the native DLM.Conclusions: From a biomechanical viewpoint, the native DLM was the most protective against lateral tibiofemoral contact stress in comparison to partially meniscectomized DLMs.(c) 2023 Elsevier B.V. All rights reserved.
引用
收藏
页码:57 / 63
页数:7
相关论文
共 50 条
  • [31] Effect of coronal plane acetabular correction on joint contact pressure in Periacetabular osteotomy: a finite-element analysis
    Kenji Kitamura
    Masanori Fujii
    Miho Iwamoto
    Satoshi Ikemura
    Satoshi Hamai
    Goro Motomura
    Yasuharu Nakashima
    BMC Musculoskeletal Disorders, 23
  • [32] Effect of coronal plane acetabular correction on joint contact pressure in Periacetabular osteotomy: a finite-element analysis
    Kitamura, Kenji
    Fujii, Masanori
    Iwamoto, Miho
    Ikemura, Satoshi
    Hamai, Satoshi
    Motomura, Goro
    Nakashima, Yasuharu
    BMC MUSCULOSKELETAL DISORDERS, 2022, 23 (01)
  • [33] Medial meniscus extrusion and varus tilt of joint line convergence angle increase stress in the medial compartment of the knee joint in the knee extension position -finite element analysis
    Kozaki, Takuhei
    Fukui, Daisuke
    Yamamoto, Ei
    Nishiyama, Daisuke
    Yamanaka, Manabu
    Murata, Akimasa
    Yamada, Hiroshi
    JOURNAL OF EXPERIMENTAL ORTHOPAEDICS, 2022, 9 (01)
  • [34] The effects of different repair methods for a posterior root tear of the lateral meniscus on the biomechanics of the knee: a finite element analysis
    Wang, Jian-Yu
    Qi, Yan-Song
    Bao, Hu-Ri-Cha
    Xu, Yong-Sheng
    Wei, Bao-Gang
    Wang, Yong-Xiang
    Ma, Bing-Xian
    Zhou, Hui-Wen
    Lv, Fei
    JOURNAL OF ORTHOPAEDIC SURGERY AND RESEARCH, 2021, 16 (01)
  • [35] The effects of different repair methods for a posterior root tear of the lateral meniscus on the biomechanics of the knee: a finite element analysis
    Jian-Yu Wang
    Yan-Song Qi
    Hu-Ri-Cha Bao
    Yong-Sheng Xu
    Bao-Gang Wei
    Yong-Xiang Wang
    Bing-Xian Ma
    Hui-Wen Zhou
    Fei Lv
    Journal of Orthopaedic Surgery and Research, 16
  • [36] Biomechanical effects of the medial meniscus horizontal tear and the resection strategy on the rabbit knee joint under resting state: finite element analysis
    Xue, Anqi
    Mao, Zuming
    Zhu, Xiaoyu
    Yang, Qiang
    Wang, Peichen
    Mao, Zimu
    Du, Mingze
    Ma, Xu
    Jiang, Dong
    Fan, Yubo
    Zhao, Feng
    FRONTIERS IN BIOENGINEERING AND BIOTECHNOLOGY, 2023, 11
  • [37] Effects of total contact insoles on the plantar stress redistribution: a finite element analysis
    Chen, WP
    Ju, CW
    Tang, FT
    CLINICAL BIOMECHANICS, 2003, 18 (06) : S17 - S24
  • [38] Finite element analysis of contact stress in the meshing process for internal gear pairs with few teeth difference
    Wei, Yangang
    Dai, Shidong
    Zhang, Xiujuan
    Key Engineering Materials, 2013, 568 : 97 - 102
  • [39] Investigation into the effect of lateral and longitudinal loads on railroad spike stress magnitude and location using finite element analysis
    Dersch, Marcus
    Roadcap, Tom
    Edwards, J. Riley
    Qian, Yu
    Kim, Jae-Yoon
    Trizotto, Matheus
    ENGINEERING FAILURE ANALYSIS, 2019, 104 : 388 - 398
  • [40] Medial meniscus extrusion and varus tilt of joint line convergence angle increase stress in the medial compartment of the knee joint in the knee extension position -finite element analysis-
    Takuhei Kozaki
    Daisuke Fukui
    Ei Yamamoto
    Daisuke Nishiyama
    Manabu Yamanaka
    Akimasa Murata
    Hiroshi Yamada
    Journal of Experimental Orthopaedics, 9