Quantifying Myocardial Blood Flow and Resistance Using 4D-Flow Cardiac Magnetic Resonance Imaging

被引:0
|
作者
Gosling, Rebecca C. [1 ,2 ,3 ]
Williams, Gareth [1 ]
Al Baraikan, Abdulaziz [1 ]
Alabed, Samer [1 ,3 ]
Levelt, Eylem [4 ]
Chowdhary, Amrit [4 ]
Swoboda, Peter P. [4 ]
Halliday, Ian [1 ,3 ]
Hose, D. Rodney [1 ,3 ]
Gunn, Julian P. [1 ,2 ,3 ]
Greenwood, John P. [4 ]
Plein, Sven [4 ]
Swift, Andrew J. [1 ,3 ]
Wild, James M. [1 ,3 ]
Garg, Pankaj [5 ]
Morris, Paul D. [1 ,2 ,3 ]
机构
[1] Univ Sheffield, Dept Infect Immun & Cardiovasc Dis, Sheffield, England
[2] Sheffield Teaching Hosp NHS Fdn Trust, Dept Cardiol, Sheffield, England
[3] Insigneo Inst Sil Med, Sheffield, England
[4] Univ Leeds, Leeds Inst Cardiovasc & Metab Med, Leeds, England
[5] Univ East Anglia, Norwich Med Sch, Norwich, Norfolk, England
基金
英国惠康基金;
关键词
CORONARY; PERFUSION; RESERVE; THERMODILUTION; ISCHEMIA;
D O I
10.1155/2023/3875924
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background. Ischaemia with nonobstructive coronary arteries is most commonly caused by coronary microvascular dysfunction but remains difficult to diagnose without invasive testing. Myocardial blood flow (MBF) can be quantified noninvasively on stress perfusion cardiac magnetic resonance (CMR) or positron emission tomography but neither is routinely used in clinical practice due to practical and technical constraints. Quantification of coronary sinus (CS) flow may represent a simpler method for CMR MBF quantification. 4D flow CMR offers comprehensive intracardiac and transvalvular flow quantification. However, it is feasibility to quantify MBF remains unknown. Methods. Patients with acute myocardial infarction (MI) and healthy volunteers underwent CMR. The CS contours were traced from the 2-chamber view. A reformatted phase contrast plane was generated through the CS, and flow was quantified using 4D flow CMR over the cardiac cycle and normalised for myocardial mass. MBF and resistance (MyoR) was determined in ten healthy volunteers, ten patients with myocardial infarction (MI) without microvascular obstruction (MVO), and ten with known MVO. Results. MBF was quantified in all 30 subjects. MBF was highest in healthy controls (123.8 +/- 48.4 mL/min), significantly lower in those with MI (85.7 +/- 30.5 mL/min), and even lower in those with MI and MVO (67.9 +/- 29.2 mL/min/) (P < 0.01 for both differences). Compared with healthy controls, MyoR was higher in those with MI and even higher in those with MI and MVO (0.79 (+/- 0.35) versus 1.10 (+/- 0.50) versus 1.50 (+/- 0.69), P = 0.02). Conclusions. MBF and MyoR can be quantified from 4D flow CMR. Resting MBF was reduced in patients with MI and MVO.
引用
收藏
页数:7
相关论文
共 50 条
  • [1] ARCAPA: 4D-flow cardiovascular magnetic resonance versus cardiac CT
    Urmeneta Ulloa, Javier
    Angel Cabrera, Jose
    Martinez de Vega, Vicente
    REVISTA ESPANOLA DE CARDIOLOGIA, 2021, 74 (05): : 449 - 449
  • [2] 4D-flow cardiac magnetic resonance in repaired anomalous pulmonary venous drainage
    Ulloa, Javier Urmeneta
    Gil, Alberto Forteza
    Cabrera, Jose Angel
    REVISTA ESPANOLA DE CARDIOLOGIA, 2025, 78 (04): : 382 - 383
  • [3] VALIDATION OF NON-CONTRAST MULTIPLE OVERLAPPING THIN SLAB 4D-FLOW CARDIAC MAGNETIC RESONANCE IMAGING
    Rashedi, Nina
    Landeras, Luis
    Mor-Avi, Victor
    Genovese, Davide
    Lai, Peng
    Wang Haonan
    Kebed, Kalie
    McClelland, Isla
    Brau, Anja
    Janich, Martin
    Lang, Roberto
    Patel, Amit R.
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2020, 75 (11) : 1680 - 1680
  • [4] 4D-flow cardiac magnetic resonance analysis of left ventricular blood flow dynamics in mid-ventricular obstructive hypertrophic cardiomyopathy
    Miyajima, K.
    Shirai, Y.
    Kin, F.
    Watanabe, T.
    Tatsuguchi, M.
    Kawaguchi, Y.
    Wakabayashi, Y.
    EUROPEAN HEART JOURNAL, 2019, 40 : 3170 - 3170
  • [5] Preclinical 4D-flow magnetic resonance phase contrast imaging of the murine aortic arch
    Braig, Moritz
    Leupold, Jochen
    Menza, Marius
    Russe, Maximilian
    Ko, Cheng-Wen
    Hennig, Juergen
    von Elverteldt, Dominik
    PLOS ONE, 2017, 12 (11):
  • [6] Pulmonary Artery Flow Using 4D Cardiac Magnetic Resonance Imaging
    Lua, S. B.
    Barrientos, P. Hall
    Ingram, J.
    Roditi, G.
    Brewis, M.
    Johnson, M.
    Church, C.
    AMERICAN JOURNAL OF RESPIRATORY AND CRITICAL CARE MEDICINE, 2024, 209
  • [7] Longitudinal Monitoring of Hepatic Blood Flow before and after TIPS by Using 4D-Flow MR Imaging
    Bannas, Peter
    Roldan-Alzate, Alejandro
    Johnson, Kevin M.
    Woods, Michael A.
    Ozkan, Orhan
    Motosugi, Utaroh
    Wieben, Oliver
    Reeder, Scott B.
    Kramer, Harald
    RADIOLOGY, 2016, 281 (02) : 574 - 582
  • [8] Validation of non-contrast multiple overlapping thin-slab 4D-flow cardiac magnetic resonance imaging
    Rashedi, Nina
    Landeras, Luis
    Mor-Avi, Victor
    Genovese, Davide
    Lai, Peng
    Wang, Haonan
    Kebed, Kalie
    McClelland, Isla
    Brau, Anja
    Janich, Martin
    Addetia, Karima
    Lang, Roberto M.
    Patel, Amit R.
    MAGNETIC RESONANCE IMAGING, 2020, 74 : 223 - 231
  • [9] Blood flow imaging by optimal matching of computational fluid dynamics to 4D-flow data
    Toger, Johannes
    Zahr, Matthew J.
    Aristokleous, Nicolas
    Bloch, Karin Markenroth
    Carlsson, Marcus
    Persson, Per-Olof
    MAGNETIC RESONANCE IN MEDICINE, 2020, 84 (04) : 2231 - 2245
  • [10] Left Atrial Flow Stasis in Patients Undergoing Pulmonary Vein Isolation for Paroxysmal Atrial Fibrillation Using 4D-Flow Magnetic Resonance Imaging
    Sheitt, Hana
    Kim, Hansuk
    Wilton, Stephen
    White, James A.
    Garcia, Julio
    APPLIED SCIENCES-BASEL, 2021, 11 (12):