Diagnostic Accuracy of a Portable Electromyography and Electrocardiography Device to Measure Sleep Bruxism in a Sleep Apnea Population: A Comparative Study

被引:2
|
作者
Cid-Verdejo, Rosana [1 ,2 ]
Gordillo, Adelaida A. Dominguez [1 ]
Sanchez-Romero, Eleuterio A. [3 ,4 ,5 ]
Garcia, Ignacio Ardizone [1 ]
Orozco, Francisco J. Martinez [6 ]
机构
[1] Univ Complutense Madrid, Fac Dent, Madrid 28040, Spain
[2] Univ Europea Madrid, Fac Biomed Sci, Dept Clin Dent, Madrid 28670, Spain
[3] Univ Europea Madrid, Fac Sport Sci, Interdisciplinary Grp Musculoskeletal Disorders, Villaviciosa De Odon 28670, Spain
[4] Univ Europea Madrid, Fac Sport Sci, Dept Physiotherapy, Villaviciosa De Odon 28670, Spain
[5] Soc Espanola Disfunc Craneomandibular & Dolor Orof, Physiotherapy & Orofacial Pain Working Grp, Madrid 28009, Spain
[6] San Carlos Univ Hosp, Clin Neurophysiol Dept, Sleep Unit, Madrid 28040, Spain
来源
CLOCKS & SLEEP | 2023年 / 5卷 / 04期
关键词
bruxism; electromyography; sleep apnea; polysomnography; sleep bruxism; sleep-wake disorders; electrocardiography; portable device; TEMPOROMANDIBULAR DISORDERS; MUSCLE-ACTIVITY; ASSOCIATION; EPIDEMIOLOGY; POLYSOMNOGRAPHY; RELIABILITY; VALIDATION; BITESTRIP; HYPOPNEA; VALIDITY;
D O I
10.3390/clockssleep5040047
中图分类号
R74 [神经病学与精神病学];
学科分类号
摘要
Background: The gold standard for diagnosing sleep bruxism (SB) and obstructive sleep apnea (OSA) is polysomnography (PSG). However, a final hypermotor muscle activity often occurs after apnea episodes, which can confuse the diagnosis of SB when using portable electromyography (EMG) devices. This study aimed to compare the number of SB episodes obtained from PSG with manual analysis by a sleep expert, and from a manual and automatic analysis of an EMG and electrocardiography (EKG) device, in a population with suspected OSA. Methods: Twenty-two subjects underwent a polysomnographic study with simultaneous recording with the EMG-EKG device. SB episodes and SB index measured with both tools and analyzed manually and automatically were compared. Masticatory muscle activity was scored according to published criteria. Patients were segmented by severity of OSA (mild, moderate, severe) following the American Academy of Sleep Medicine (AASM) criteria. ANOVA and the Bland-Altman plot were used to quantify the agreement between both methods. The concordance was calculated through the intraclass correlation coefficient (ICC). Results: On average, the total events of SB per night in the PSG study were (8.41 +/- 0.85), lower than the one obtained with EMG-EKG manual (14.64 +/- 0.76) and automatic (22.68 +/- 16.02) analysis. The mean number of SB episodes decreases from the non-OSA group to the OSA group with both PSG (5.93 +/- 8.64) and EMG-EKG analyses (automatic = 22.47 +/- 18.07, manual = 13.93 +/- 11.08). However, this decrease was minor in proportion compared to the automatic EMG-EKG analysis mode (from 23.14 to 22.47). The ICC based on the number of SB episodes in the segmented sample by severity degree of OSA along the three tools shows a moderate correlation in the non-OSA (0.61) and mild OSA (0.53) groups. However, it is poorly correlated in the moderate (0.24) and severe (0.23) OSA groups: the EMG-EKG automatic analysis measures 14.27 units more than PSG. The results of the manual EMG-EKG analysis improved this correlation but are not good enough. Conclusions: The results obtained in the PSG manual analysis and those obtained by the EMG-EKG device with automatic and manual analysis for the diagnosis of SB are acceptable but only in patients without OSA or with mild OSA. In patients with moderate or severe OSA, SB diagnosis with portable electromyography devices can be confused due to apneas, and further study is needed to investigate this.
引用
收藏
页码:717 / 733
页数:17
相关论文
共 50 条
  • [1] Diagnostic accuracy of a portable device (Bruxoff®) to measure sleep bruxism
    Yanez-Regonesi, Fernanda
    Eisa, Elfatih
    Judge, Stephanie
    Carlson, Charles
    Okeson, Jeffrey
    Moreno-Hay, Isabel
    JOURNAL OF ORAL REHABILITATION, 2023, 50 (04) : 258 - 266
  • [2] Diagnostic validity of the use of a portable single-channel electromyography device for sleep bruxism
    Stuginski-Barbosa, Juliana
    Porporatti, Andre Luis
    Costa, Yuri Martins
    Svensson, Peter
    Rodrigues Conti, Paulo Cesar
    SLEEP AND BREATHING, 2016, 20 (02) : 695 - 702
  • [3] Diagnostic validity of the use of a portable single-channel electromyography device for sleep bruxism
    Juliana Stuginski-Barbosa
    André Luís Porporatti
    Yuri Martins Costa
    Peter Svensson
    Paulo César Rodrigues Conti
    Sleep and Breathing, 2016, 20 : 695 - 702
  • [4] Diagnostic accuracy of portable sleep monitors in pediatric sleep apnea: A systematic review
    Landry, Vivianne
    Semsar-Kazerooni, Koorosh
    Chen, Tanya
    Gurberg, Joshua
    Nguyen, Lily H. P.
    Constantin, Evelyn
    SLEEP MEDICINE REVIEWS, 2024, 78
  • [5] Accuracy of sleep bruxism scoring based on electromyography traces of different jaw muscles in individuals with obstructive sleep apnea
    Li, Deshui
    Aarab, Ghizlane
    Lobbezoo, Frank
    Arcache, Patrick
    Lavigne, Gilles J.
    Huynh, Nelly
    JOURNAL OF CLINICAL SLEEP MEDICINE, 2022, 18 (06): : 1609 - 1615
  • [6] Diagnostic accuracy of portable instrumental devices to measure sleep bruxism: a systematic literature review of polysomnographic studies
    Manfredini, D.
    Ahlberg, J.
    Castroflorio, T.
    Poggio, C. E.
    Guarda-Nardini, L.
    Lobbezoo, F.
    JOURNAL OF ORAL REHABILITATION, 2014, 41 (11) : 836 - 842
  • [7] Reliability of a portable device for the detection of sleep bruxism
    Deregibus, Andrea
    Castroflorio, Tommaso
    Bargellini, Andrea
    Debernardi, Cesare
    CLINICAL ORAL INVESTIGATIONS, 2014, 18 (08) : 2037 - 2043
  • [8] Reliability of a portable device for the detection of sleep bruxism
    Andrea Deregibus
    Tommaso Castroflorio
    Andrea Bargellini
    Cesare Debernardi
    Clinical Oral Investigations, 2014, 18 : 2037 - 2043
  • [9] Validating diagnostic accuracy of a portable sleep testing diagnostic device in an outpatient population of heart failure patients with sleep disordered breathing
    Ines Arajo, I.
    Araujo, M.
    Marques, F.
    Moniz, P.
    Pereira, P.
    Marques, S.
    Ferreira, R.
    Andre, S.
    Campos, L.
    Fonseca, C.
    EUROPEAN JOURNAL OF HEART FAILURE, 2015, 17 : 67 - 67
  • [10] DIAGNOSTIC ACCURACY OF HOME SLEEP STUDIES FOR SLEEP APNEA
    Grant, B.
    SLEEP, 2009, 32 : A232 - A233