Long-term bolt preload relaxation and contact pressure distribution in clamping anchorages for CFRP plates

被引:17
作者
Ding, Guozhen [1 ,2 ]
Feng, Peng [1 ]
Wang, Yu [3 ]
Ai, Pengcheng [4 ]
Wang, Qinyu [1 ]
机构
[1] Tsinghua Univ, Dept Civil Engn, Key Lab Civil Engn Safety & Durabil, China Educ Minist, Beijing 100084, Peoples R China
[2] Imperial Coll London, Dept Civil & Environm Engn, South Kensington, London SW7 2AZ, England
[3] Chongqing Jiaotong Univ, Sch Civil Engn, Chongqing 400074, Peoples R China
[4] Wuxi First Engn Sci Res Inst, Wuxi 214035, Peoples R China
基金
国家重点研发计划; 中国国家自然科学基金;
关键词
Bolt preload relaxation; CFRP plate; Clamping anchorage; Pressure distribution; Elastic interaction; STRESS-SLIP RELATIONSHIP; MODEL; CABLES;
D O I
10.1016/j.compstruct.2023.117780
中图分类号
O3 [力学];
学科分类号
08 ; 0801 ;
摘要
Clamping anchorages are commonly used to anchor carbon fiber reinforced polymer (CFRP) plates, and the anchoring performance is significantly impacted by bolt preload. This research presents experimental and numerical investigations of long-term bolt preload relaxation in clamping anchorages for CFRP plates. First, a compression test was conducted to obtain the elastic modulus in the thickness direction of CFRP plates. Subsequently, four types of relaxation tests (single bolt, planar and curved anchorage, external load effect, and thickened anchorage) were conducted, considering the effects of the number of CFRP plates, anchorage type, external load, and initial preload. The elastic interaction during the tightening process was also investigated. The contact pressure distribution was simulated through the finite element method, which is in good agreement with the experimental results obtained from pressure papers. To fit relaxation test results and predict million-hour relaxation, different theoretical models were employed. The results indicate that the number of CFRP plates is crucial to preload relaxation, and the presence of CFRP plates introduces strong elastic interactions between bolts in the anchorage. Preload relaxation also increases under external loads and with the increase in initial preload. Curved anchorage has less bolt preload relaxation in the long term under external loads. Additionally, thickened anchorages have a more uniform contact pressure distribution due to the improved pressure diffusion mechanism.
引用
收藏
页数:14
相关论文
共 43 条
[1]   Novel self-anchored CFRP cable system: Concept and anchorage behavior [J].
Ai, Pengcheng ;
Feng, Peng ;
Lin, Hongwei ;
Zhu, Pengcheng ;
Ding, Guozhen .
COMPOSITE STRUCTURES, 2021, 263
[2]   Influence of stress relaxation on clamp-up force in hybrid composite-to-metal bolted joints [J].
Caccese, Vincent ;
Berube, Keith A. ;
Fernandez, Mauricio ;
Melo, J. Daniel ;
Kabche, Jean Paul .
COMPOSITE STRUCTURES, 2009, 89 (02) :285-293
[3]   Finite element analysis and mathematical characterization of contact pressure distribution in bolted joints [J].
Cao, Jianbin ;
Zhang, Zhousuo .
JOURNAL OF MECHANICAL SCIENCE AND TECHNOLOGY, 2019, 33 (10) :4715-4725
[4]   Novel pre-clamp lap joint for CFRP plates: Design and experimental study [J].
Ding, Guozhen ;
Feng, Peng ;
Wang, Yu ;
Ai, Pengcheng .
COMPOSITE STRUCTURES, 2022, 302
[5]   A novel variable curvature clamping anchor for the multilayer CFRP plate cable: Concept, numerical investigation, and design proposals [J].
Duo, Yongyu ;
Liu, Xiaogang ;
Yue, Qingrui ;
Chen, Hongbing .
STRUCTURES, 2022, 43 :164-177
[6]  
Feng P, 2022, P IABSE C NANJ 2022, P2070
[7]   Mechanical Analysis of Stress Distribution in a Carbon Fiber-Reinforced Polymer Rod Bonding Anchor [J].
Feng, Peng ;
Zhang, Pan ;
Meng, Xinmiao ;
Ye, Lieping .
POLYMERS, 2014, 6 (04) :1129-1143
[8]  
Geffroy R., 2002, PROC FOOTBRIDGE
[9]  
Horn W, 1993, 34 STRUCTURES STRUCT, P1350
[10]   Development of prestressed unbonded and bonded CFRP strengthening solutions for tensile metallic members [J].
Hosseini, Ardalan ;
Ghafoori, Elyas ;
Motavalli, Masoud ;
Nussbaumer, Alain ;
Zhao, Xiao-Ling ;
Al-Mahaidi, Riadh ;
Terrasi, Giovanni .