Corneal Outcomes Following Cataract Surgery Using Ophthalmic Viscosurgical Devices Composed of Chondroitin Sulfate-Hyaluronic Acid: A Systematic Review and Meta-Analysis

被引:6
作者
Hsiao, Chia-Wen [1 ]
Cheng, Hang [1 ]
Ghafouri, Rana [2 ]
Ferko, Nicole C. [2 ,4 ]
Ayres, Brandon [3 ]
机构
[1] Alcon, Ft Worth, TX USA
[2] Eversana, Burlington, ON, Canada
[3] Thomas Jefferson Univ Hosp, Philadelphia, PA USA
[4] Eversana Life Sci Serv, 3228 S Serv Rd, Burlington, ON, Canada
关键词
cataract; ophthalmic viscosurgical device; endothelial cell density; corneal thickness; endothelial protection; ENDOTHELIAL-CELL LOSS; SOFT-SHELL TECHNIQUE; INTRAOCULAR-PRESSURE; VISCOELASTIC SUBSTANCES; PHACOEMULSIFICATION; HEALON5; SAFETY; DISCOVISC; EFFICACY; THICKNESS;
D O I
10.2147/OPTH.S419863
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
Background: Ophthalmic viscosurgical devices (OVDs) are commonly used during cataract surgery to protect the corneal endothelium. A systematic literature review and meta-analysis were conducted to assess the clinical evidence of OVDs composed of chondroitin sulfate-hyaluronic acid (CS-HA) versus other OVDs in maintaining endothelial cell density (ECD) and corneal thickness (CT).Methods: MEDLINE and EMBASE databases were searched from 2000 to 2020. Randomized controlled trials (RCTs, N & GE; 20 per group) comparing an OVD containing CS-HA (ie, VISCOAT & REG;, DuoVisc & REG; or DisCoVisc & REG;) to any other OVD were included. The identified comparators were limited to the OVDs found in the literature, which included those composed of HA-only or hydroxypropyl methylcellulose (HPMC). Outcomes of focus included changes in ECD (baseline to 3 months) and CT (baseline to 24 hours). Meta-analyses were performed using R software, to assess mean differences (MD) in ECD and CT change between CS-HA OVDs and HA-only or HPMC OVDs.Results: A total of 966 abstracts were screened, and data were extracted from 12 RCTs. Meta-analyses using a random-effects model revealed significantly lower percent (%) decrease in ECD for CS-HA OVDs compared to both HA-only (MD: -4.10%; 95% CI: -5.81 to -2.40; p < 0.0001; 9 studies) and HPMC (MD: -6.47%; 95% CI: -10.41 to -2.52; p = 0.001; 2 studies) products. Similarly, % CT increase was significantly lower with CS-HA than with HA-only OVDs (MD: -3.22%; 95% CI: -6.24% to -0.20%; p = 0.04; 4 studies). However, there were no significant differences when comparing % CT change between CS-HA and HPMC OVDs (MD: 2.65%; 95% CI: -0.43% to 0.95%; p = 0.4; 2 studies).Conclusion: CS-HA OVDs lead to less postoperative loss of endothelial cells and may better protect corneal endothelium during cataract surgery, relative to other OVDs. Future randomized studies may be needed to solidify these findings.
引用
收藏
页码:2083 / 2096
页数:14
相关论文
共 47 条
[1]  
Alcon, 2014, DUOVISC
[2]  
[Anonymous], COCHRANE HDB SYSTEMA
[3]   Risk Factors for Corneal Endothelial Cell Loss in Patients with Pseudoexfoliation Syndrome [J].
Aoki, Takanori ;
Kitazawa, Koji ;
Inatomi, Tsutomu ;
Kusada, Natsuki ;
Horiuchi, Noriko ;
Takeda, Kazunori ;
Yokoi, Norihiko ;
Kinoshita, Shigeru ;
Sotozono, Chie .
SCIENTIFIC REPORTS, 2020, 10 (01)
[4]   New classification of ophthalmic viscosurgical devices - 2005 [J].
Arshinoff, SA ;
Jafari, M .
JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2005, 31 (11) :2167-2171
[5]   Intraocular pressure after bilateral cataract surgery using Healon, Healon5, and Healon GV [J].
Arshinoff, SA ;
Albiani, DA ;
Taylor-Laporte, J .
JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2002, 28 (04) :617-625
[6]   Prospective, randomized trial comparing MicroVisc Plus and Healon GV in routine phacoemulsification [J].
Arshinoff, SA ;
Hofman, I .
JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 1998, 24 (06) :814-820
[7]   Dispersive-cohesive viscoelastic soft shell technique [J].
Arshinoff, SA .
JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 1999, 25 (02) :167-173
[8]   Tri-soft shell technique [J].
Arshinoff, Steve A. ;
Norman, Richard .
JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2013, 39 (08) :1196-1203
[9]   Comparison of the performance and safety of 2 ophthalmic viscosurgical device in cataract surgery [J].
Auffarth, Gerd U. ;
Auerbach, Florian N. ;
Rabsilber, Tanja ;
Gegundez, Jose A. ;
Cuina, Ricardo ;
Renard, Yves ;
Vinciguerra, Paolo ;
Camesasca, Fabrizio ;
Van Cauwenberge, Francoise ;
Amzallag, Thierry ;
Van Setten, Gysbert ;
Holzer, Mike P. .
JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2017, 43 (01) :87-94
[10]  
Bamdad Shahram, 2018, Electron Physician, V10, P6616, DOI 10.19082/6616