Theoretical prediction model of transient performance for a mixed flow pump under fast start-up conditions

被引:25
作者
Liu, Ming [1 ]
Han, Yadong [1 ]
Tan, Lei [1 ]
Lu, Yangping [1 ]
Ma, Can [2 ]
Gou, Jinlan [2 ]
机构
[1] Tsinghua Univ, Dept Energy & Power Engn, State Key Lab Hydrosci & Engn, Beijing 100084, Peoples R China
[2] Wuhan 2nd Ship Design & Res Inst, Sci & Technol Thermal Energy & Power Lab, Wuhan 430205, Peoples R China
基金
中国国家自然科学基金;
关键词
CENTRIFUGAL PUMP; NUMERICAL-SIMULATION; TURBINE; STEADY; SPEED;
D O I
10.1063/5.0138575
中图分类号
O3 [力学];
学科分类号
08 ; 0801 ;
摘要
There always appear unsteady characteristics during start-up periods of pumps, which can lead to instability of the entire system. However, the lack of a method for quickly and accurately predicting pump start-up performance makes it difficult to analyze the performance of the overall system during the period. To this end, a theoretical model to predict pump transient performance under fast start-up conditions is established in the present study. The theoretical prediction model for pump steady performance is built based on loss modeling first. Then, the balance between pump transient head and pipeline system is considered to determine transient pump performance. A time stepping algorithm is proposed to solve transient pump performance during start-up periods. The established theoretical model and the corresponding time stepping algorithm are applied to a mixed flow pump under fast start-up conditions with various acceleration time. The predicted evolution of pump head shows good agreement with experimental measurements, and average relative errors are within 10% for both steady and transient conditions. In addition, the theoretical model is applied to analyze the transient performance of oscillating curves and impact head. The mechanism for predicted oscillating results and the relation between peak impact head and the acceleration of rotation speed are revealed.
引用
收藏
页数:11
相关论文
共 42 条
  • [1] Prediction of the steady and non-steady flow performance of a highly loaded mixed flow turbine
    Abidat, M
    Hachemi, M
    Hamidou, MK
    Baines, NC
    [J]. PROCEEDINGS OF THE INSTITUTION OF MECHANICAL ENGINEERS PART A-JOURNAL OF POWER AND ENERGY, 1998, 212 (A3) : 173 - 184
  • [2] Prediction method of impeller performance and analysis of loss mechanism for mixed-flow pump
    Bing Hao
    Tan Lei
    Cao ShuLiang
    Lu Li
    [J]. SCIENCE CHINA-TECHNOLOGICAL SCIENCES, 2012, 55 (07) : 1988 - 1998
  • [3] TRANSIENT FLOW PERFORMANCE IN A MULTILOOP NUCLEAR REACTOR SYSTEM
    BOYD, GM
    ROSSER, RM
    CARDWELL, BB
    [J]. NUCLEAR SCIENCE AND ENGINEERING, 1961, 9 (04) : 442 - 454
  • [4] Pressure Fluctuation Characteristics Analysis of Centrifugal Pump as Turbine in Its Start-Up Process
    Chai, Baodui
    Yang, Junhu
    Wang, Xiaohui
    Jiang, Bingxiao
    [J]. ACTUATORS, 2022, 11 (05)
  • [5] A One-Dimensional Flow Analysis for the Prediction of Centrifugal Pump Performance Characteristics
    El-Naggar, Mohammed Ahmed
    [J]. INTERNATIONAL JOURNAL OF ROTATING MACHINERY, 2013, 2013
  • [6] A model for the analysis of pump start-up transients in Tehran Research Reactor
    Farhadi, Kazem
    Bousbia-Salah, Anis
    D'Auria, Franscesco
    [J]. PROGRESS IN NUCLEAR ENERGY, 2007, 49 (07) : 499 - 510
  • [7] Finnemore E.J., 2002, FLUID MECH ENG APPL, VTenth
  • [8] Analysis of reactor coolant pump transient performance in primary coolant system during start-up period
    Gao, Hong
    Gao, Feng
    Zhao, Xianchao
    Chen, Jie
    Cao, Xuewu
    [J]. ANNALS OF NUCLEAR ENERGY, 2013, 54 : 202 - 208
  • [9] Transient flow analysis in reactor coolant pump systems during flow coastdown period
    Gao, Hong
    Gao, Feng
    Zhao, Xianchao
    Chen, Jie
    Cao, Xuewu
    [J]. NUCLEAR ENGINEERING AND DESIGN, 2011, 241 (02) : 509 - 514
  • [10] ANALYSIS OF PUMP START-UP TRANSIENTS
    GROVER, RB
    KORANNE, SM
    [J]. NUCLEAR ENGINEERING AND DESIGN, 1981, 67 (01) : 137 - 141