The mismatch response in normal hearing adults: a performance comparison with stimuli relevant for objective validation of hearing aid fittings

被引:1
作者
Maslin, Michael R. D. [1 ,2 ]
Wise, Kim J. [2 ,3 ]
Purdy, Suzanne C. [2 ,3 ]
机构
[1] Univ Canterbury, Sch Psychol Speech & Hearing, Canterbury 8041, New Zealand
[2] Eisdell Moore Ctr Hearing & Balance Res, Auckland, New Zealand
[3] Univ Auckland, Sch Psychol, Speech Sci, Auckland, New Zealand
关键词
Mismatch response; cortical auditory evoked potentials; hearing aid validation; hearing loss; infants; AUDITORY-EVOKED POTENTIALS; NEGATIVITY; NOISE; CAEPS; DISCRIMINATION; FREQUENCY; INFANTS;
D O I
10.1080/14992027.2022.2142682
中图分类号
R36 [病理学]; R76 [耳鼻咽喉科学];
学科分类号
100104 ; 100213 ;
摘要
ObjectiveA long-standing observation is that the Mismatch Response (MMR) has the potential to offer a clinically feasible index of sound discrimination. However, findings that positively identify MMRs at the individual level have been mixed, even for those who are normally hearing and who can discriminate sounds behaviourally. This complicates interpretation when an MMR is not observed. The objective of this study was to determine the reliability of the MMR using an optimised paradigm and a range of stimuli relevant to audiological applications in relation to objective verification of hearing aid fittings.DesignMMRs were measured using an optimised 3-deviant paradigm in response to a range of sounds designed for aided and unaided sound field assessments, including complex tones (CTs) and speech-like signals.Study sampleSeventeen normally hearing adults (18-56 years).ResultsThe most robust MMRs were recorded in response to CTs; responses were positively identified in 50 out of 51 instances (98%), assessed via objective Hotelling's T-2 bias-free statistical analyses.ConclusionsThe results indicate that CTs in conjunction with optimised recording and analysis parameters offer the potential to elicit robust MMRs, supporting future utilisation of MMRs for clinical audiological applications.
引用
收藏
页码:1084 / 1094
页数:11
相关论文
共 41 条
[31]   Comparison of Speech Perception Performance According to Prosody Change Between People With Normal Hearing and Cochlear Implant Users [J].
Kim, Eun Yeon ;
Seol, Hye Yoon .
JOURNAL OF AUDIOLOGY AND OTOLOGY, 2024, 28 (02) :119-125
[32]   Comparisons of Auditory Steady State Response and Behavioral Air Conduction and Bone Conduction Thresholds for Infants and Adults With Normal Hearing [J].
Casey, Kelly-Ann ;
Small, Susan A. .
EAR AND HEARING, 2014, 35 (04) :423-439
[33]   Dichotic listening and otoacoustic emissions: Shared variance between cochlear function and dichotic listening performance in adults with normal hearing [J].
Markevych, Vladlena ;
Asbjornsen, Arve E. ;
Lind, Ola ;
Plante, Elena ;
Cone, Barbara .
BRAIN AND COGNITION, 2011, 76 (02) :332-339
[34]   A Set of Time-and-Frequency-Localized Short-Duration Speech-Like Stimuli for Assessing Hearing-Aid Performance via Cortical Auditory-Evoked Potentials [J].
Stone, Michael A. ;
Visram, Anisa ;
Harte, James M. ;
Munro, Kevin J. .
TRENDS IN HEARING, 2019, 23
[35]   At-home computerized executive-function training to improve cognition and mobility in normal-hearing adults and older hearing aid users: a multi-centre, single-blinded randomized controlled trial [J].
Downey, Rachel ;
Gagne, Nathan ;
Mohanathas, Niroshica ;
Campos, Jennifer L. ;
Pichora-Fuller, Kathleen M. ;
Bherer, Louis ;
Lussier, Maxime ;
Phillips, Natalie A. ;
Wittich, Walter ;
St-Onge, Nancy ;
Gagne, Jean-Pierre ;
Li, Karen .
BMC NEUROLOGY, 2023, 23 (01)
[36]   At-home computerized executive-function training to improve cognition and mobility in normal-hearing adults and older hearing aid users: a multi-centre, single-blinded randomized controlled trial [J].
Rachel Downey ;
Nathan Gagné ;
Niroshica Mohanathas ;
Jennifer L. Campos ;
Kathleen M. Pichora-Fuller ;
Louis Bherer ;
Maxime Lussier ;
Natalie A. Phillips ;
Walter Wittich ;
Nancy St-Onge ;
Jean-Pierre Gagné ;
Karen Li .
BMC Neurology, 23
[37]   Fast Click Rate Electrocochleography and Auditory Brainstem Response in Normal-Hearing Adults Using Continuous Loop Averaging Deconvolution [J].
Kaf, Wafaa A. ;
Lewis, Kelly M. ;
Yavuz, Erdem ;
Dixon, Samantha M. ;
Van Ess, Mark ;
Jamos, Abdullah M. ;
Delgado, Rafael E. .
EAR AND HEARING, 2017, 38 (02) :244-254
[38]   Performance-Intensity Functions for Normal-Hearing Adults and Children Using Computer-Aided Speech Perception Assessment [J].
McCreery, Ryan ;
Ito, Rindy ;
Spratford, Merry ;
Lewis, Dawna ;
Hoover, Brenda ;
Stelmachowicz, Patricia G. .
EAR AND HEARING, 2010, 31 (01) :95-101
[39]   Masked Speech Perception with Bone Conduction Device, Contralateral Routing of Signals Hearing Aid, and Cochlear Implant Use in Adults with Single-Sided Deafness: A Prospective Hearing Device Comparison using a Unified Testing Framework [J].
Wesarg, Thomas ;
Kuntz, Iris ;
Jung, Lorenz ;
Wiebe, Konstantin ;
Schatzer, Reinhold ;
Brill, Stefan ;
Aschendorff, Antje ;
Arndt, Susan .
AUDIOLOGY AND NEUROTOLOGY, 2024, 29 (04) :271-289
[40]   Test-Retest Reliability of Level-Specific CE-Chirp Auditory Brainstem Response in Normal-Hearing Adults [J].
Jamal, Fatin Nabilah ;
Dzulkarnain, Ahmad Aidil Arafat ;
Shahrudin, Fatin Amira ;
Marzuki, Muhammad Nasrullah .
JOURNAL OF AUDIOLOGY AND OTOLOGY, 2021, 25 (01) :14-21