Dosimetric comparison of gantry and horizontal fixed-beam proton therapy treatment plans for base of skull chordoma

被引:2
作者
Shierlaw, Emma [1 ,2 ]
Penfold, Melanie [1 ]
Crain, Rosanna [1 ,2 ]
Santos, Alexandre M. C. [1 ,2 ,3 ]
Penfold, Scott N. [1 ,3 ,4 ]
机构
[1] Australian Bragg Ctr Proton Therapy & Res, Adelaide, SA, Australia
[2] Cent Adelaide Local Hlth Network, Radiat Oncol, Adelaide, SA, Australia
[3] Univ Adelaide, Dept Phys, Adelaide, SA, Australia
[4] Australian Bragg Ctr Proton Therapy & Res, Adelaide, SA 5000, Australia
关键词
Particle beam therapy; planning; proton therapy;
D O I
10.1002/jmrs.742
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
IntroductionAustralia's first proton beam therapy (PBT) centre will house a fixed-beam room and two gantry rooms. As the only PBT facility in Australia for at least the short term, there is a need to efficiently allocate treatment appointments between the gantry and fixed-beam rooms. This planning study assesses the dosimetric differences between fixed-beam and gantry-based treatment plans for base of skull chordoma, one of the core indications likely to be referred for PBT in Australia.MethodsRetrospective gantry-based and fixed-beam treatment plans were generated for five patients with base of skull chordoma. Fixed-beam plans were generated with a conventional horizontal patient positioning system. Robust intensity modulated proton therapy (IMPT) optimisation and evaluation techniques were used for both delivery systems. Plans were designed to maximise target coverage while adhering to maximum dose constraints to neighbouring critical organs at risk.ResultsRobust target coverage and integral dose were found to be approximately equivalent for the gantry-based and fixed-beam plans. Doses to specific organs at risk could be reduced with the gantry-based geometry; however, the gantry-based plans did not exhibit a general decrease in doses to organs at risk.ConclusionA fixed-beam treatment plan was found to be non-inferior to a gantry-based treatment plan for all base of skull patients included in the current study. Fixed-beam systems significantly reduce the upfront cost of proton beam therapy. A dosimetric comparison of fixed-beam and gantry IMPT delivery systems is performed for five bases of skull chordoma patients. The fixed-beam dosimetry was found to be non-inferior to the gantry dosimetry for the patients studied.image
引用
收藏
页码:19 / 26
页数:8
相关论文
共 50 条
  • [21] Proton therapy with a fixed beamline for skull-base chordomas and chondrosarcomas: outcomes and toxicity
    Konstantin Gordon
    Igor Gulidov
    Sergey Koryakin
    Daniil Smyk
    Tatyana Makeenkova
    Danil Gogolin
    Olga Lepilina
    Olga Golovanova
    Alexey Semenov
    Sergey Dujenko
    Kira Medvedeva
    Yuri Mardynsky
    Radiation Oncology, 16
  • [22] Comparison of beam optics for normal conducting and superconducting gantry beamlines applied to proton therapy
    Qin, Bin
    Zhao, Runxiao
    Xu, Liu
    Chen, Qushan
    Chen, Heming
    Liu, Kaifeng
    Yang, Jun
    Li, Dong
    INTERNATIONAL JOURNAL OF MODERN PHYSICS A, 2019, 34 (36):
  • [23] Proton or Carbon Ion Therapy for Skull Base Chordoma: Rationale and First Analysis of a Mono-Institutional Experience
    Tubin, Slavisa
    Fossati, Piero
    Mock, Ulrike
    Luetgendorf-Caucig, Carola
    Flechl, Birgit
    Pelak, Maciej
    Georg, Petra
    Fussl, Christoph
    Carlino, Antonio
    Stock, Markus
    Hug, Eugen
    CANCERS, 2023, 15 (07)
  • [24] Long term outcomes of patients with skull-base low-grade chondrosarcoma and chordoma patients treated with pencil beam scanning proton therapy
    Weber, Damien C.
    Malyapa, Robert
    Albertini, Francesca
    Bolsi, Alessandra
    Kliebsch, Ulrike
    Walser, Marc
    Pica, Alessia
    Combescure, Christophe
    Lomax, Antony J.
    Schneider, Ralf
    RADIOTHERAPY AND ONCOLOGY, 2016, 120 (01) : 169 - 174
  • [25] Endoscopic Resection Followed by Proton Therapy With Pencil Beam Scanning for Skull Base Tumors
    Leeman, Jonathan E.
    Lee, Nancy Y.
    Zhou, Ying
    Neal, Brian
    Sine, Kevin
    Tabar, Viviane
    Cohen, Marc A.
    LARYNGOSCOPE, 2019, 129 (06) : 1313 - 1317
  • [26] Adjuvant Proton Beam Therapy in the Management of Thymoma: A Dosimetric Comparison and Acute Toxicities
    Parikh, Rahul R.
    Rhome, Ryan
    Hug, Eugen
    Tsai, Henry
    Cahlon, Oren
    Chon, Brian
    Goenka, Anuj
    CLINICAL LUNG CANCER, 2016, 17 (05) : 362 - 366
  • [27] A comparison of proton therapy and IMRT treatment plans for prostate radiotherapy
    Dowdell, S. J.
    Metcalfe, P. E.
    Morales, J. E.
    Jackson, M.
    Rosenfeld, A. B.
    AUSTRALASIAN PHYSICAL & ENGINEERING SCIENCES IN MEDICINE, 2008, 31 (04) : 325 - 331
  • [28] A comparison of proton therapy and IMRT treatment plans for prostate radiotherapy
    S. J. Dowdell
    P. E. Metcalfe
    J. E. Morales
    M. Jackson
    A. B. Rosenfeld
    Australasian Physics & Engineering Sciences in Medicine, 2008, 31 : 325 - 331
  • [29] IMPORTANCE OF PRECISE POSITIONING FOR PROTON-BEAM THERAPY IN THE BASE OF SKULL AND CERVICAL-SPINE
    TATSUZAKI, H
    URIE, MM
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 1991, 21 (03): : 757 - 765
  • [30] Proton beam therapy for skull base chordomas in 106 patients: A dose adaptive radiation protocol
    Fung, Vivien
    Calugaru, Valentin
    Bolle, Stephanie
    Mammara, Hamid
    Alapetite, Claire
    Maingon, Philippe
    De Marzi, Ludovic
    Froelich, Sebastien
    Habrand, Jean-Louis
    Dendale, Remi
    Noel, Georges
    Feuvret, Loic
    RADIOTHERAPY AND ONCOLOGY, 2018, 128 (02) : 198 - 202