Comparative studies of the sensitivities of sparse and full geometries of Total-Body PET scanners built from crystals and plastic scintillators

被引:9
作者
Dadgar, M. [1 ,2 ]
Parzych, S. [1 ,2 ]
Baran, J. [1 ,2 ]
Chug, N. [1 ,2 ]
Curceanu, C. [4 ]
Czerwinski, E. [1 ,2 ]
Dulski, K. [1 ,2 ]
Elyan, K. [1 ,2 ]
Gajos, A. [1 ,2 ]
Hiesmayr, B. C. [5 ]
Kaplon, L. [1 ,2 ]
Klimaszewski, K. [6 ]
Konieczka, P. [6 ]
Korcyl, G. [1 ,2 ]
Kozik, T. [1 ]
Krzemien, W. [7 ]
Kumar, D. [1 ,2 ]
Niedzwiecki, S. [1 ,2 ]
Panek, D. [1 ,2 ]
Perez del Rio, E. [1 ,2 ]
Raczynski, L. [6 ]
Sharma, S. [1 ,2 ]
Shivani, S. [1 ,2 ]
Shopa, R. Y. [6 ]
Skurzok, M. [1 ,2 ]
Stepien, E. L. [1 ,2 ,3 ]
Tayefi Ardebili, F. [1 ,2 ]
Tayefi Ardebili, K. [1 ,2 ]
Vandenberghe, S. [8 ]
Wislicki, W. [6 ]
Moskal, P. [1 ,2 ,3 ]
机构
[1] Jagiellonian Univ, Fac Phys Astron & Appl Comp Sci, Dept Expt Particle Phys & Applicat, Krakow, Poland
[2] Jagiellonian Univ, Total Body Jagiellonian PET Lab, Krakow, Poland
[3] Jagiellonian Univ, Theranost Ctr, Krakow, Poland
[4] INFN, Lab Nazl Frascati, Frascati, Italy
[5] Univ Vienna, Fac Phys, Vienna, Austria
[6] Natl Ctr Nucl Res, Dept Complex Syst, Otwock, Poland
[7] Natl Ctr Nucl Res, High Energy Phys Div, Otwock, Poland
[8] Ghent Univ IBiTech, Dept Elect & Informat Syst, MEDISIP, Ghent, Belgium
关键词
Total-Body PET; Sensitivity; GATE simulation; J-PET; uEXPLORER; IMAGE-RECONSTRUCTION; OPPORTUNITIES; SIMULATION; RESOLUTION; STRIPS;
D O I
10.1186/s40658-023-00572-5
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
BackgroundAlongside the benefits of Total-Body imaging modalities, such as higher sensitivity, single-bed position, low dose imaging, etc., their final construction cost prevents worldwide utilization. The main aim of this study is to present a simulation-based comparison of the sensitivities of existing and currently developed tomographs to introduce a cost-efficient solution for constructing a Total-Body PET scanner based on plastic scintillators.MethodsFor the case of this study, eight tomographs based on the uEXPLORER configuration with different scintillator materials (BGO, LYSO), axial field-of-view (97.4 cm and 194.8 cm), and detector configurations (full and sparse) were simulated. In addition, 8 J-PET scanners with different configurations, such as various axial field-of-view (200 cm and 250 cm), different cross sections of plastic scintillator, and multiple numbers of plastic scintillator layers (2, 3, and 4), based on J-PET technology have been simulated by GATE software. Furthermore, Siemens' Biograph Vision has been simulated to compare the results with standard PET scans. Two types of simulations have been performed. The first one with a centrally located source with a diameter of 1 mm and a length of 250 cm, and the second one with the same source inside a water-filled cylindrical phantom with a diameter of 20 cm and a length of 183 cm.ResultsWith regards to sensitivity, among all the proposed scanners, the ones constructed with BGO crystals give the best performance (similar to\documentclass[12pt]{minimal} \usepackage{amsmath} \usepackage{wasysym} \usepackage{amsfonts} \usepackage{amssymb} \usepackage{amsbsy} \usepackage{mathrsfs} \usepackage{upgreek} \setlength{\oddsidemargin}{-69pt} \begin{document}$$\sim$$\end{document} 350 cps/kBq at the center). The utilization of sparse geometry or LYSO crystals significantly lowers the achievable sensitivity of such systems. The J-PET design gives a similar sensitivity to the sparse LYSO crystal-based detectors while having full detector coverage over the body. Moreover, it provides uniform sensitivity over the body with additional gain on its sides and provides the possibility for high-quality brain imaging.ConclusionTaking into account not only the sensitivity but also the price of Total-Body PET tomographs, which till now was one of the main obstacles in their widespread clinical availability, the J-PET tomography system based on plastic scintillators could be a cost-efficient alternative for Total-Body PET scanners.
引用
收藏
页数:14
相关论文
共 42 条
[1]   Unparalleled and revolutionary impact of PET imaging on research and day to day practice of medicine [J].
Alavi, Abass ;
Werner, Thomas J. ;
Stepien, Ewa L. ;
Moskal, Pawel .
BIO-ALGORITHMS AND MED-SYSTEMS, 2021, 17 (04) :203-212
[2]   Potential and Most Relevant Applications of Total Body PET/CT Imaging [J].
Alavi, Abass ;
Saboury, Babak ;
Nardo, Lorenzo ;
Zhang, Vincent ;
Wang, Meiyun ;
Li, Hongdi ;
Raynor, William Y. ;
Werner, Thomas J. ;
Hoilund-Carlsen, Poul F. ;
Revheim, Mona-Elisabeth .
CLINICAL NUCLEAR MEDICINE, 2022, 47 (01) :43-55
[3]   First Human Imaging Studies with the EXPLORER Total-Body PET Scanner [J].
Badawi, Ramsey D. ;
Shi, Hongcheng ;
Hu, Pengcheng ;
Chen, Shuguang ;
Xu, Tianyi ;
Price, Patricia M. ;
Ding, Yu ;
Spencer, Benjamin A. ;
Nardo, Lorenzo ;
Liu, Weiping ;
Bao, Jun ;
Jones, Terry ;
Li, Hongdi ;
Cherry, Simon R. .
JOURNAL OF NUCLEAR MEDICINE, 2019, 60 (03) :299-303
[4]   From a PMT-based to a SiPM-based PET system: a study to define matched acquisition/reconstruction parameters and NEMA performance of the Biograph Vision 450 [J].
Carlier, Thomas ;
Ferrer, Ludovic ;
Conti, Maurizio ;
Bodet-Milin, Caroline ;
Rousseau, Caroline ;
Bercier, Yanic ;
Bendriem, Bernard ;
Kraeber-Bodere, Francoise .
EJNMMI PHYSICS, 2020, 7 (01)
[5]   Total-Body PET: Maximizing Sensitivity to Create New Opportunities for Clinical Research and Patient Care [J].
Cherry, Simon R. ;
Jones, Terry ;
Karp, Joel S. ;
Qi, Jinyi ;
Moses, William W. ;
Badawi, Ramsey D. .
JOURNAL OF NUCLEAR MEDICINE, 2018, 59 (01) :3-12
[6]   A Simulation Study to Estimate Optimum LOR Angular Acceptance for the Image Reconstruction with the Total-Body J-PET [J].
Dadgar, Meysam ;
Parzych, Szymon ;
Ardebili, Faranak Tayefi .
MEDICAL IMAGE UNDERSTANDING AND ANALYSIS (MIUA 2021), 2021, 12722 :189-200
[7]   New Challenges for PET Image Reconstruction for Total-Body Imaging [J].
Efthimiou, Nikos .
PET CLINICS, 2020, 15 (04) :453-461
[8]   GATE:: a simulation toolkit for PET and SPECT [J].
Jan, S ;
Santin, G ;
Strul, D ;
Staelens, S ;
Assié, K ;
Autret, D ;
Avner, S ;
Barbier, R ;
Bardiès, M ;
Bloomfield, PM ;
Brasse, D ;
Breton, V ;
Bruyndonckx, P ;
Buvat, I ;
Chatziioannou, AF ;
Choi, Y ;
Chung, YH ;
Comtat, C ;
Donnarieix, D ;
Ferrer, L ;
Glick, SJ ;
Groiselle, CJ ;
Guez, D ;
Honore, PF ;
Kerhoas-Cavata, S ;
Kirov, AS ;
Kohli, V ;
Koole, M ;
Krieguer, M ;
van der Laan, DJ ;
Lamare, F ;
Largeron, G ;
Lartizien, C ;
Lazaro, D ;
Maas, MC ;
Maigne, L ;
Mayet, F ;
Melot, F ;
Merheb, C ;
Pennacchio, E ;
Perez, J ;
Pietrzyk, U ;
Rannou, FR ;
Rey, M ;
Schaart, DR ;
Schmidtlein, CR ;
Simon, L ;
Song, TY ;
Vieira, JM ;
Visvikis, D .
PHYSICS IN MEDICINE AND BIOLOGY, 2004, 49 (19) :4543-4561
[9]   Technical Attenuation Length Measurement of Plastic Scintillator Strips for the Total-Body J-PET Scanner [J].
Kaplon, Ukasz .
IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 2020, 67 (10) :2286-2289
[10]   Physical performance of adaptive axial FOV PET scanners with a sparse detector block rings or a checkerboard configuration [J].
Karakatsanis, Nicolas A. ;
Nehmeh, Mohammad H. ;
Conti, Maurizio ;
Bal, Girish ;
Gonzalez, Antonio J. ;
Nehmeh, Sadek A. .
PHYSICS IN MEDICINE AND BIOLOGY, 2022, 67 (10)