A transceiver integrated piezoelectric micromachined ultrasound transducer array for underwater imaging

被引:6
|
作者
Yao, Yunxin [1 ]
Jia, Licheng [1 ]
Liu, Chongbin [1 ]
Wang, Xiangyang [1 ]
Sun, Chengliang [1 ,2 ,3 ]
Liu, Sheng [1 ,3 ]
Wu, Guoqiang [1 ,2 ,3 ]
机构
[1] Wuhan Univ, Inst Technol Sci, Wuhan 430072, Hubei, Peoples R China
[2] Hubei Yangtze Memory Labs, Wuhan 430205, Hubei, Peoples R China
[3] Wuhan Univ, Sch Microelect, Wuhan 430072, Hubei, Peoples R China
关键词
Underwater imaging; Piezoelectric micromachined ultrasonic; transducers (PMUTs); Microelectromechanical systems(MEMS); Transceiver integrated; Scandium-doped aluminum nitride (ScAlN); DESIGN;
D O I
10.1016/j.sna.2023.114476
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
In this article, a scandium-doped aluminum nitride (Sc0.2Al0.8N) piezoelectric micromachined ultrasound transducer (PMUT) array for underwater imaging is presented. The reported PMUT array integrates a transmitter and a receiver in one transduction cell, in which the outer top electrode is used for transmitting while the inner top electrode is employed for simultaneously receiving ultrasonic waves, respectively. A 7 x 8 transduction cell array with characteristic size of 500 & mu;m is designed in a bioinspired honeycomb architecture and developed based on a piezoelectric on silicon-on-insulator (SOI) platform. The top electrode of the transduction cell is split into the outer and inner sections with the optimized size ratio for achieving transceiver integration in one cell. The fabricated PMUT array exhibits a transmit sensitivity of 146.59 dB (re: 1 & mu;Pa/V), and a receive sensitivity of -173.70 dB (re: 1 V/& mu;Pa) at its resonant frequency of around 150 kHz in water. In order to demonstrate the feasibility of underwater imaging, the PMUT array and its signal conditional circuits are packaged using an acoustically transparent material. Ultrasonic pulse-echo imaging with the developed PMUT array is demonstrated without implementation of a switching circuit to separate the transmit and reflected signals, due to the transceiver integration approach proposed in our work. This work demonstrates the feasibility of underwater imaging for the transceiver integrated PMUT array, which has great commercial value for minimized and portable underwater imaging.
引用
收藏
页数:8
相关论文
共 50 条
  • [41] Micromachined capacitive transducer arrays for intravascular ultrasound imaging
    Guldiken, RO
    Degertekin, FL
    MEMS 2005 MIAMI: TECHNICAL DIGEST, 2005, : 315 - 318
  • [42] Piezoelectric Micromachined Ultrasonic Transducer Array for Micro Audio Directional Loudspeaker
    Li, Xuesheng
    Xu, Limei
    Sun, Ting
    2013 IEEE INTERNATIONAL CONFERENCE ON MECHATRONICS AND AUTOMATION (ICMA), 2013, : 450 - 455
  • [43] Waveguide piezoelectric micromachined ultrasonic transducer array for short-range pulse-echo imaging
    Lu, Y.
    Tang, H.
    Wang, Q.
    Fung, S.
    Tsai, J. M.
    Daneman, M.
    Boser, B. E.
    Horsley, D. A.
    APPLIED PHYSICS LETTERS, 2015, 106 (19)
  • [44] Mechanosensitive Channel Stimulation System using Low-Intensity Ultrasound by Piezoelectric Micromachined Ultrasonic Transducer Array
    Lee, Wonjun
    Kim, Samhwan
    Jung, Joontaek
    Kang, Woojin
    Shin, Eunjung
    Moon, Cheil
    Choi, Hongsoo
    2016 IEEE INTERNATIONAL ULTRASONICS SYMPOSIUM (IUS), 2016,
  • [45] A dual-frequency piezoelectric micromachined ultrasound transducer array with low inter-element coupling effects
    Liu, Lifang
    Ji, Weiliang
    Xing, Zhanqiang
    Sun, Xiangyu
    Chen, Yu
    Du, Yijia
    Qin, Feng
    JOURNAL OF MICROMECHANICS AND MICROENGINEERING, 2021, 31 (04)
  • [46] DESIGN AND EVALUATION OF A TRANSRECTAL PHASED PIEZOELECTRIC MICROMACHINED ULTRASOUND TRANSDUCER (PMUT) ARRAY FOR THERMAL TREATMENT OF PROSTATE CANCER
    Lweesy, Khaldon
    Fora, Malak
    El-Khalil, Hossam
    Kothapalli, Sri-Rajasekhar
    Dangi, Ajay
    JOURNAL OF ENGINEERING SCIENCE AND TECHNOLOGY, 2021, 16 (02): : 1386 - 1401
  • [47] Design of Micromachined Self-focusing Piezoelectric Composite Ultrasound Transducer
    Jian, Xiaohua
    Xiang, Yongjia
    Han, Zhile
    Li, Zhangjian
    Cui, Yaoyao
    2014 36TH ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY (EMBC), 2014, : 550 - 553
  • [48] Design and Fabrication of a Stacked Three-Phase Piezoelectric Composites Ring Array Underwater Ultrasound Transducer
    Xia, Lili
    Wang, Hongwei
    Huang, Qiguo
    MATERIALS, 2021, 14 (20)
  • [49] First In Vivo Use of a Capacitive Micromachined Ultrasound Transducer Array-Based Imaging and Ablation Catheter
    Stephens, Douglas N.
    Truong, Uyen T.
    Nikoozadeh, Amin
    Oralkan, Omer
    Seo, Chi Hyung
    Cannata, Jonathan
    Dentinger, Aaron
    Thomenius, Kai
    de la Rama, Alan
    Nguyen, Tho
    Lin, Feng
    Khuri-Yakub, Pierre
    Mahajan, Aman
    Shivkumar, Kalyanam
    O'Donnell, Matt
    Sahn, David J.
    JOURNAL OF ULTRASOUND IN MEDICINE, 2012, 31 (02) : 247 - 256
  • [50] UNDERWATER PIEZOELECTRIC TRANSDUCER
    RECUERO, M
    VAQUERO, M
    TABERNERO, F
    ULTRASONICS, 1987, 25 (06) : 375 - 375