A transceiver integrated piezoelectric micromachined ultrasound transducer array for underwater imaging

被引:7
|
作者
Yao, Yunxin [1 ]
Jia, Licheng [1 ]
Liu, Chongbin [1 ]
Wang, Xiangyang [1 ]
Sun, Chengliang [1 ,2 ,3 ]
Liu, Sheng [1 ,3 ]
Wu, Guoqiang [1 ,2 ,3 ]
机构
[1] Wuhan Univ, Inst Technol Sci, Wuhan 430072, Hubei, Peoples R China
[2] Hubei Yangtze Memory Labs, Wuhan 430205, Hubei, Peoples R China
[3] Wuhan Univ, Sch Microelect, Wuhan 430072, Hubei, Peoples R China
关键词
Underwater imaging; Piezoelectric micromachined ultrasonic; transducers (PMUTs); Microelectromechanical systems(MEMS); Transceiver integrated; Scandium-doped aluminum nitride (ScAlN); DESIGN;
D O I
10.1016/j.sna.2023.114476
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
In this article, a scandium-doped aluminum nitride (Sc0.2Al0.8N) piezoelectric micromachined ultrasound transducer (PMUT) array for underwater imaging is presented. The reported PMUT array integrates a transmitter and a receiver in one transduction cell, in which the outer top electrode is used for transmitting while the inner top electrode is employed for simultaneously receiving ultrasonic waves, respectively. A 7 x 8 transduction cell array with characteristic size of 500 & mu;m is designed in a bioinspired honeycomb architecture and developed based on a piezoelectric on silicon-on-insulator (SOI) platform. The top electrode of the transduction cell is split into the outer and inner sections with the optimized size ratio for achieving transceiver integration in one cell. The fabricated PMUT array exhibits a transmit sensitivity of 146.59 dB (re: 1 & mu;Pa/V), and a receive sensitivity of -173.70 dB (re: 1 V/& mu;Pa) at its resonant frequency of around 150 kHz in water. In order to demonstrate the feasibility of underwater imaging, the PMUT array and its signal conditional circuits are packaged using an acoustically transparent material. Ultrasonic pulse-echo imaging with the developed PMUT array is demonstrated without implementation of a switching circuit to separate the transmit and reflected signals, due to the transceiver integration approach proposed in our work. This work demonstrates the feasibility of underwater imaging for the transceiver integrated PMUT array, which has great commercial value for minimized and portable underwater imaging.
引用
收藏
页数:8
相关论文
共 50 条
  • [31] Exploitation of Capacitive Micromachined Transducers for Nonlinear Ultrasound Imaging
    Novell, Anthony
    Legros, Mathieu
    Felix, Nicolas
    Bouakaz, Ayache
    IEEE TRANSACTIONS ON ULTRASONICS FERROELECTRICS AND FREQUENCY CONTROL, 2009, 56 (12) : 2733 - 2743
  • [32] PMMA-Based Wafer-Bonded Capacitive Micromachined Ultrasonic Transducer for Underwater Applications
    Ahmad, Mansoor
    Bozkurt, Ayhan
    Farhanieh, Omid
    MICROMACHINES, 2019, 10 (05)
  • [33] Research on optimization sparse method for capacitive micromachined ultrasonic transducer array: heuristic algorithm
    Zhang, Tian
    Zhang, Wendong
    Shao, XingLing
    Wu, Yang
    SENSOR REVIEW, 2021, 41 (03) : 260 - 270
  • [34] A 32 x 32 Capacitive Micromachined Ultrasonic Transducer Array Manufactured in Standard CMOS
    Lemmerhirt, David F.
    Cheng, Xiaoyang
    White, Robert D.
    Rich, Collin A.
    Zhang, Man
    Fowlkes, J. Brian
    Kripfgans, Oliver D.
    IEEE TRANSACTIONS ON ULTRASONICS FERROELECTRICS AND FREQUENCY CONTROL, 2012, 59 (07) : 1521 - 1536
  • [35] A row-column addressed micromachined ultrasonic transducer array for surface scanning applications
    Wong, Lawrence L. P.
    Chen, Albert I. H.
    Li, Zhenhao
    Logan, Andrew S.
    Yeow, John T. W.
    ULTRASONICS, 2014, 54 (08) : 2072 - 2080
  • [36] Thin-Film Piezoelectric Micromachined Ultrasound Transducers in Biomedical Applications: A Review
    Wong, Sean J. Z.
    Roy, Kaustav
    Lee, Chengkuo
    Zhu, Yao
    IEEE TRANSACTIONS ON ULTRASONICS FERROELECTRICS AND FREQUENCY CONTROL, 2024, 71 (06) : 622 - 637
  • [37] A preliminary evaluation work on a 3-D ultrasound imaging system for 2-D array transducer
    Zhong, Xiaoli
    Li, Xu
    Yang, Jiali
    Li, Chunyu
    Song, Junjie
    Ding, Mingyue
    Ming Yuchi
    MEDICAL IMAGING 2016: ULTRASONIC IMAGING AND TOMOGRAPHY, 2016, 9790
  • [38] Flexible transceiver array for ultrahigh field human MR imaging
    Wu, Bing
    Zhang, Xiaoliang
    Wang, Chunsheng
    Li, Ye
    Pang, Yong
    Lu, Jonathan
    Xu, Duan
    Majumdar, Sharmila
    Nelson, Sarah J.
    Vigneron, Daniel B.
    MAGNETIC RESONANCE IN MEDICINE, 2012, 68 (04) : 1332 - 1338
  • [39] Underwater Imaging Using a 1 x 16 CMUT Linear Array
    Zhang, Rui
    Zhang, Wendong
    He, Changde
    Zhang, Yongmei
    Song, Jinlong
    Xue, Chenyang
    SENSORS, 2016, 16 (03)
  • [40] A micromachined piezoelectric ultrasonic transducer operating in d33 mode using square interdigital electrodes
    Wang, Chao
    Wang, Zheyao
    Ren, Tian-Ling
    Zhu, Yiping
    Yang, Yi
    Wu, Xiaoming
    Wang, Haining
    Fang, Huajun
    Liu, Litian
    IEEE SENSORS JOURNAL, 2007, 7 (7-8) : 967 - 976