Analysis of the Ability of a Distal Tibial Anatomical Locking Plate to Capture the Distal Tibial Fragments in Patients with Pilon Fractures

被引:0
作者
Liu, Jun-Hong [1 ]
Zhang, Qiang [1 ]
Wei, Guo-Hua [1 ]
Liu, Liang [1 ]
Mu, Xin [1 ]
Li, Mao-Lin [1 ]
Wu, Zong-De [1 ,2 ]
机构
[1] Sichuan Orthopaed Hosp, Foot & Ankle Dept 1, Chengdu, Peoples R China
[2] Sichuan Orthopaed Hosp, Foot & Ankle Dept 1, Chengdu 610000, Sichuan, Peoples R China
关键词
Capture Fragments; Anatomical Locking Plate; Pilon Fracture; Distal Tibia Anatomical Plate; ANKLE;
D O I
10.1111/os.13796
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Objective: Although pilon fractures are rare in clinical practice, they are difficult to treat because of their complexity. Effective fixation of the fracture fragment is the key to the treatment of pilon fractures. Plate osteosynthesis is common clinically, but there are many types of plates and the evaluation of the effect of fixation plates is not comprehensive.This study attempted to compare the capture effect of different fixation plates on the fracture fragments based on 3D modeling and fine distinctions of fracture fragments.Methods: The computed tomography (CT) images before treatment of 127 patients with pilon fractures from January 2019 to December 2021 were retrospectively collected. The fracture lines were mapped and digitally displayed as 3D images using MIMICS 21 software. APLUS distal tibia anatomical locking plate (Plate A) and ZIMMER distal tibia anatomical plate (Plate B) were placed on a pseudo-bone model and CT scans were used to determine the number of screws in the major and minor fragments of pilon fractures. The frequency of the two plates capturing the fracture fragments was recorded.Results: Under Assumption 1 or 2, Plate A performed significantly better than Plate B in capturing the major, Chaput, Volkmann, medial malleolus, and die-punch fracture fragments. Plate A captured markedly more minor fragments than Plate B under Assumption 2 but was not significantly different from Plate B under Assumption 1. Plate A or Plate B showed no obvious difference between major and minor capture rates under the same assumption, and A1 or B1 showed a markedly higher capture rate compared with A2 or B2. In addition, there was a significant positive correlation between the major capture rate and the major fragments in B1, and a significant negative correlation between the minor capture rate and the minor fragments in Plates A and B. However, there was no correlation between the major capture rate of Plate A and the major fragments.Conclusion: The APLUS distal tibial anatomical locking plate is superior to the ZIMMER distal tibia anatomical plate in the ability to capture distal tibial fragments in pilon fracture cases.
引用
收藏
页码:2674 / 2682
页数:9
相关论文
共 41 条
  • [31] Biomechanical Effect of Distal Tibial Oblique Osteotomy: A Preliminary Finite-Element Analysis
    Sakai, Tatsuya
    Fujii, Masanori
    Kitamura, Kenji
    Tanaka, Hirofumi
    Mawatari, Masaaki
    CUREUS JOURNAL OF MEDICAL SCIENCE, 2024, 16 (02)
  • [32] Osteoperiosteal Iliac Autograft Transplantation for Unreconstructable Tibial Plafond After Malunions of Pilon Fractures in Young Patients
    Gan, Ting-Jiang
    Ma, Xi-Kun
    Li, Ya-Xing
    Chen, Yu
    Liu, Xi
    Li, Jia
    Zhang, Hui
    FOOT & ANKLE INTERNATIONAL, 2024, 45 (01) : 33 - 43
  • [33] Osteochondral autograft transplantation in the treatment of AO/OTA type C3 tibial plafond fractures with irreducibly comminuted area and/or cartilage delamination in the distal tibial facet
    Liu, Xi
    Zhang, Hui
    Li, Yaxing
    Chen, Yu
    Yin, Shijiu
    Wu, Shizhou
    Qin, Boquan
    Ren, Yi
    Gan, Tingjiang
    INJURY-INTERNATIONAL JOURNAL OF THE CARE OF THE INJURED, 2022, 53 (04): : 1523 - 1531
  • [34] Distal Fibula Pro-Tibial Screws in Salvage Fixation of Bimalleolar Ankle Fractures in Osteoporotic Bone - A Novel Technique
    Beshr, Mostafa
    Dixon, James
    Stevenson, Iain
    ARCHIVES OF BONE AND JOINT SURGERY-ABJS, 2024, 12 (05): : 361 - 364
  • [35] Treatment of Neer IIb Distal Clavicle Fractures Using Anatomical Locked Plate Fixation With Coracoclavicular Ligament Augmentation
    Han, Lei
    Hu, Yungen
    Quan, Renfu
    Fang, Weili
    Jin, Bo
    Huang, Ligang
    JOURNAL OF HAND SURGERY-AMERICAN VOLUME, 2017, 42 (12): : 1036.e1 - 1036.e6
  • [36] A randomised pilot trial of "locking plate" fixation versus intramedullary nailing for extra-articular fractures of the distal tibia
    Mauffrey, C.
    McGuinness, K.
    Parsons, N.
    Achten, J.
    Costa, M. L.
    JOURNAL OF BONE AND JOINT SURGERY-BRITISH VOLUME, 2012, 94B (05): : 704 - 708
  • [37] Accelerated rehabilitation in treating neer type V distal clavicle fractures using anatomical locking plates with coracoclavicular ligament augmentation
    Zou, Min
    Duan, Xin
    Li, Mufan
    Sun, Jiachen
    HELIYON, 2023, 9 (01)
  • [38] Surgical Treatment of Extra-Articular or Simple Intra-Articular Distal Tibial Fractures: External Fixation versus Intramedullary Nailing
    Ristiniemi, Jukka
    Luukinen, Patrik
    Ohtonen, Pasi
    JOURNAL OF ORTHOPAEDIC TRAUMA, 2011, 25 (02) : 101 - 105
  • [39] Operative Treatment of Distal Tibial Fractures in Children Managed With Epiphyseal Screws: A Comparison of Outcomes When Screws Are Retained Versus Removed Following Fracture Union
    Zimmerman, Remy
    Rupp, Garrett
    Barger, Kurt
    Fang, William
    Thomas, Evelyn
    Bastrom, Tracey
    Pennock, Andrew
    Schlechter, John
    JOURNAL OF PEDIATRIC ORTHOPAEDICS, 2024, 44 (07) : e588 - e591
  • [40] Finite element analysis of the treatment of a minimally invasive approach combined with a novel anatomical locking plate for scapular body fractures
    Guo, Zhanpeng
    Guo, Yue
    Wang, Yansong
    Bi, Yunlong
    Deng, Yu
    Cao, Yang
    Huang, Mina
    JOURNAL OF ORTHOPAEDIC SURGERY AND RESEARCH, 2024, 19 (01):