A General Diode Open-Circuit Fault Diagnosis Method for Autotransformer Rectifier Unit Considering Grid Voltage Disturbance

被引:2
作者
Yang, Chao [1 ]
Zhang, Fanghua [1 ]
Cheng, Long [2 ]
Zhang, Zhaorong [1 ]
机构
[1] Nanjing Univ Aeronaut & Astronaut, Coll Automat Engn, Nanjing 210016, Peoples R China
[2] Anhui Agr Univ, Dept Elect Engn, Hefei 230036, Peoples R China
基金
中国国家自然科学基金;
关键词
Rectifiers; Fault diagnosis; Circuit faults; Semiconductor diodes; Feature extraction; Bridge circuits; Transformers; Autotransformer rectifier unit (ATRU); dc-link output voltage (DLOV); fault diagnosis; grid voltage disturbance; Hausdorff distance (HD); sag; universality; ROTATING RECTIFIER; TRANSFORMER; CONVERTERS;
D O I
10.1109/JESTPE.2022.3220370
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
It is crucial for the reliable operation of the autotransformer rectifier unit (ATRU) to accurately diagnose diode open-circuit (OC) fault. However, grid voltage disturbance may lead to misdiagnosis by existing methods. This article takes the 18-pulse ATRU as an example and first analyzes its sag-based fault feature in the dc-link output voltage (DLOV) caused by diode OC fault under no grid voltage disturbance. Then, the reason for misdiagnosis under grid voltage disturbance is discussed. Subsequently, a general diode OC fault diagnosis method with strong immunity to grid voltage disturbance is proposed. In the proposed method, the DLOV waveform is divided equally according to the number of rectified pulses. Hausdorff distance (HD) algorithm is employed to extract the sag-based fault feature by calculating the similarity between the DLOV sampling sequence and the constructed template sequence. To be immune to grid voltage disturbance, the template sequence is adaptively generated as per the sampling sequence in each interval. Also, the generalized minimum failure mode is defined to normalize two sequences for good universality. With the help of the phase of grid single-phase voltage, OC faults can be detected and located according to the interval positions with the sag. Finally, simulation and experimental results confirm the strong immunity of the proposed method to grid voltage disturbance and its good universality to the different ATRUs.
引用
收藏
页码:2214 / 2226
页数:13
相关论文
共 50 条
  • [31] A Robust Open-Circuit Fault Diagnosis Method for Three-Phase Interleaved Boost Converter
    Li, Chuanfeng
    Yu, Yang
    Tang, Tingyan
    Liu, Qingxin
    Peng, Xiyuan
    IEEE TRANSACTIONS ON POWER ELECTRONICS, 2022, 37 (09) : 11187 - 11198
  • [32] An open-circuit fault-diagnosis method for inverters based on phase current
    Cheng, Shu
    Zhao, Jundong
    Chen, Chunyang
    Li, Kaidi
    Wu, Xun
    Yu, Tianjian
    Yu, Yongsheng
    TRANSPORTATION SAFETY AND ENVIRONMENT, 2020, 2 (02) : 148 - 160
  • [33] A Voltage Vector Residual Estimation Method Based on Current Path Tracking for T-Type Inverter Open-Circuit Fault Diagnosis
    Wang, Borong
    Li, Zhan
    Bai, Zhihong
    Krein, Philip T.
    Ma, Hao
    IEEE TRANSACTIONS ON POWER ELECTRONICS, 2021, 36 (12) : 13460 - 13477
  • [34] Open-Circuit Fault Diagnosis Method for Inverter in PMSM Drives Considering Closed-Loop Regulation
    Liu, Bo
    Shi, Tingna
    Zhang, Guozheng
    Chen, Wei
    Xia, Changliang
    IEEE JOURNAL OF EMERGING AND SELECTED TOPICS IN POWER ELECTRONICS, 2024, 12 (05) : 5298 - 5310
  • [35] Parallel Open-Circuit Fault Diagnosis Method of a Cascaded Full-Bridge NPC Inverter With Model Predictive Control
    Wei, Xinwei
    Wang, Hongliang
    Luo, An
    He, Zhixing
    Zhu, Xiaonan
    Sun, Renjie
    Chen, Xinyue
    IEEE TRANSACTIONS ON INDUSTRIAL ELECTRONICS, 2021, 68 (10) : 10180 - 10192
  • [36] A Residual-Based Open-Circuit Fault Diagnosis Approach for Voltage Source Power Converters
    Zhang, Mingyuan
    Zhang, Zhenbin
    Liu, Xiaodong
    Zhang, Zhenkun
    Li, Zhen
    Liu, Yanhua
    6TH IEEE INTERNATIONAL CONFERENCE ON PREDICTIVE CONTROL OF ELECTRICAL DRIVES AND POWER ELECTRONICS (PRECEDE 2021), 2021, : 970 - 974
  • [37] Diagnosis method of open-circuit fault for T-type three-level inverter based on residual voltage
    Chen, Danjiang
    Liu, Yutian
    Zhou, Junwei
    Zhang, Shaozhong
    JOURNAL OF COMPUTATIONAL METHODS IN SCIENCES AND ENGINEERING, 2020, 20 (04) : 1143 - 1153
  • [38] A Diagnosis Method of Inverter Open-Circuit Fault Based on Interval Sliding Mode Observer
    Li, Jin
    Zhang, Youmin
    2022 4TH INTERNATIONAL CONFERENCE ON SMART POWER & INTERNET ENERGY SYSTEMS, SPIES, 2022, : 604 - 608
  • [39] Open-circuit fault diagnosis method of DAB converter based on information fusion and DRSN
    Zhao Y.
    He Y.
    Xing Z.
    Du B.
    Dianli Zidonghua Shebei/Electric Power Automation Equipment, 2023, 43 (02): : 112 - 118
  • [40] A Hypothesis Method for T-Type Three-Level Inverters Open-Circuit Fault Diagnosis Based on Output Phase Voltage Model
    Zhang, Weiwei
    He, Yigang
    IEEE TRANSACTIONS ON POWER ELECTRONICS, 2022, 37 (08) : 9718 - 9732