A General Diode Open-Circuit Fault Diagnosis Method for Autotransformer Rectifier Unit Considering Grid Voltage Disturbance

被引:2
|
作者
Yang, Chao [1 ]
Zhang, Fanghua [1 ]
Cheng, Long [2 ]
Zhang, Zhaorong [1 ]
机构
[1] Nanjing Univ Aeronaut & Astronaut, Coll Automat Engn, Nanjing 210016, Peoples R China
[2] Anhui Agr Univ, Dept Elect Engn, Hefei 230036, Peoples R China
基金
中国国家自然科学基金;
关键词
Rectifiers; Fault diagnosis; Circuit faults; Semiconductor diodes; Feature extraction; Bridge circuits; Transformers; Autotransformer rectifier unit (ATRU); dc-link output voltage (DLOV); fault diagnosis; grid voltage disturbance; Hausdorff distance (HD); sag; universality; ROTATING RECTIFIER; TRANSFORMER; CONVERTERS;
D O I
10.1109/JESTPE.2022.3220370
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
It is crucial for the reliable operation of the autotransformer rectifier unit (ATRU) to accurately diagnose diode open-circuit (OC) fault. However, grid voltage disturbance may lead to misdiagnosis by existing methods. This article takes the 18-pulse ATRU as an example and first analyzes its sag-based fault feature in the dc-link output voltage (DLOV) caused by diode OC fault under no grid voltage disturbance. Then, the reason for misdiagnosis under grid voltage disturbance is discussed. Subsequently, a general diode OC fault diagnosis method with strong immunity to grid voltage disturbance is proposed. In the proposed method, the DLOV waveform is divided equally according to the number of rectified pulses. Hausdorff distance (HD) algorithm is employed to extract the sag-based fault feature by calculating the similarity between the DLOV sampling sequence and the constructed template sequence. To be immune to grid voltage disturbance, the template sequence is adaptively generated as per the sampling sequence in each interval. Also, the generalized minimum failure mode is defined to normalize two sequences for good universality. With the help of the phase of grid single-phase voltage, OC faults can be detected and located according to the interval positions with the sag. Finally, simulation and experimental results confirm the strong immunity of the proposed method to grid voltage disturbance and its good universality to the different ATRUs.
引用
收藏
页码:2214 / 2226
页数:13
相关论文
共 50 条
  • [1] Diode Open-Circuit Fault Diagnosis Based on Hausdorff Distance for Autotransformer Rectifier Unit
    Yang, Chao
    Wu, Donghua
    Liu, Yidan
    Jia, Qian
    Zhang, Fanghua
    2021 IEEE 12TH ENERGY CONVERSION CONGRESS AND EXPOSITION - ASIA (ECCE ASIA), 2021, : 1532 - 1536
  • [2] A Novel Open-Circuit Fault Diagnosis Method for Voltage Source Inverter
    Mei, Yang
    Yuan, Hui
    2018 IEEE INTERNATIONAL POWER ELECTRONICS AND APPLICATION CONFERENCE AND EXPOSITION (PEAC), 2018, : 1819 - 1824
  • [3] A Space Vector Based Diagnosis Method for Switch Open-Circuit Fault in Vienna Rectifier
    Liu, Menghu
    Peng, Li
    Xu, Wenzhe
    Guo, Xinyue
    Chen, Cai
    2022 IEEE ENERGY CONVERSION CONGRESS AND EXPOSITION (ECCE), 2022,
  • [4] Analysis and Diagnosis on Open-circuit Fault of Diode Rectifier in 12-phase Synchronous Generator System
    Huang, Ziguo
    Sun, Yuguang
    Wang, Shanming
    Yu, Xiwen
    2014 16TH EUROPEAN CONFERENCE ON POWER ELECTRONICS AND APPLICATIONS (EPE'14-ECCE EUROPE), 2014,
  • [5] Diode Open-Circuit Fault Detection in Rectifier Bridge of the Brushless Synchronous Generator
    Rahnama, M.
    Vahedi, A.
    Alikhani, A. M.
    Takorabet, N.
    2018 XIII INTERNATIONAL CONFERENCE ON ELECTRICAL MACHINES (ICEM), 2018, : 1821 - 1826
  • [6] Open-Circuit Fault Diagnosis for Rectifier Stage in Indirect Matrix Converter
    Shi, Baoping
    Zhou, Bo
    Han, Na
    Qin, Xianhui
    Zhou, Xingwei
    Zhang, Jian
    PROCEEDINGS OF THE IECON 2016 - 42ND ANNUAL CONFERENCE OF THE IEEE INDUSTRIAL ELECTRONICS SOCIETY, 2016, : 6273 - 6277
  • [7] IGBT open-circuit fault diagnosis for VSC-HVDC rectifier
    Jing Y.-Z.
    Liao Z.-Z.
    Gong Q.-W.
    Qian C.
    Peng T.
    Zhang C.-H.
    Dianji yu Kongzhi Xuebao/Electric Machines and Control, 2021, 25 (03): : 104 - 114
  • [8] An Open-Circuit Fault Diagnosis for Three-Phase PWM Rectifier Without Grid Voltage Sensor Based on Phase Angle Partition
    Li, Chunjie
    Hu, Jianing
    Zhao, Mingwei
    Zeng, Wei
    IEEE TRANSACTIONS ON CIRCUITS AND SYSTEMS I-REGULAR PAPERS, 2024, 71 (11) : 5318 - 5328
  • [9] Open-Circuit Fault Research on Asymmetric Delta-Polygon 18-Pulse Autotransformer Rectifier Unit for More Electric Aircraft
    Yang, Chao
    Zhang, Fanghua
    Cheng, Long
    Zhang, Zhaorong
    IEEE TRANSACTIONS ON POWER ELECTRONICS, 2022, 37 (12) : 14615 - 14630
  • [10] Open-circuit fault diagnosis and voltage sensor fault tolerant control of a single phase pulsed width modulated rectifier
    Ben Youssef, Ahlem
    El Khil, Sejir Khojet
    Belkhodja, Ilhem Slama
    MATHEMATICS AND COMPUTERS IN SIMULATION, 2017, 131 : 234 - 252