Assessment of selected biochemical and immunological parameters after treatment by Cosmetic Procedures

被引:0
作者
Al-Karawi, Abdullah Salim [1 ,2 ,3 ]
Atoom, Ali Mahmoud [1 ,3 ]
Al-Adwan, Safwan Mahmoud [1 ,3 ]
Adwan, Sofia Wasfi [4 ]
机构
[1] Al Ahliyya Amman Univ, Al Salt, Jordan
[2] Al Hadi Univ Coll, Med Lab Technol, Baghdad, Iraq
[3] Al Ahliyya Amman Univ, Pharmacol & Diagnost Res Ctr, Amman, Jordan
[4] Amer Univ Madaba, Madaba, Jordan
来源
JOURNAL OF POPULATION THERAPEUTICS AND CLINICAL PHARMACOLOGY | 2023年 / 30卷 / 02期
关键词
effect; botulinum toxin; BOTOX; hyaluronic acid; biochemical parameters; hematological parameters; immunological parameters; HYALURONIC-ACID FILLERS; BOTULINUM-TOXIN; MUSCLE MASS; COMPLICATIONS; REJUVENATION; CREATININE; INJECTION; SAFETY; SERUM;
D O I
10.47750/jptcp.2023.1099
中图分类号
R9 [药学];
学科分类号
1007 ;
摘要
Background: The use of non-invasive cosmetic procedures such as Botulinum toxin and hyaluronic acid filler (HA) are commonly used in cosmetic and therapeutic. However, BOTOX therapy is generally considered safe and without significant adverse effects. However, these treatments' impacts must be understood and investigated thoroughly. The objective of this prospective study was to evaluate the impact of using injections of hyaluronic acid filler (HA) and BOTOX on some human biochemical parameters, CBC, and inflammatory markers.Methods: Eighty-five subjects who have undergone BOTOX and/or HA injections were recruited. Samples of study and control groups were collected into EDTA for CBC and serum tubes for the analysis of the rest of the parameters.Results: Our results revealed that using BOTOX and HA filler has no significant effect on ALT, AST, GGT, and CK-MB levels (p-value > 0.05). While there was a decrease in ALP level in subjects injected with both BOTOX and HA filler. Moreover, we discovered that two of our study groups had significantly higher serum LDH levels than the control group. CRP, TNF-alpha, and IL-17 were elevated in the study group compared with the control group. However, this difference was statistically insignificant (p-value > 0.05).Conclusion: Accordingly, using BOTOX and HA filler may result in mild changes in clinical laboratory tests. Future investigations are now necessary to highlight the influence of these cosmetic procedures on various clinical laboratory parameters.
引用
收藏
页码:E201 / E213
页数:13
相关论文
共 50 条
  • [21] Effects of the anaesthetic/tranquillizer treatments on selected plasma biochemical parameters in NZW rabbits
    Gil, AG
    Illera, JC
    Silván, G
    Illera, M
    LABORATORY ANIMALS, 2003, 37 (02) : 155 - 161
  • [22] EFFECT ON BIOCHEMICAL PARAMETERS IN NATURALLY INFECTED CALVES WITH GIARDIASIS AFTER TREATMENT WITH ALBENDAZOLE IN VAN PROVINCE, TURKEY
    Ragbetli, Cennet
    Tanritanir, Pinar
    Yilmaz, Hasan
    Yoruk, Ibrahim
    Ozdemir, Halime
    INDIAN JOURNAL OF ANIMAL RESEARCH, 2014, 48 (01) : 38 - 44
  • [23] The Price of Beauty: A Literature Review on Non-Tuberculous Mycobacteria Infection After Cosmetic Procedures
    Ren, Hao
    Xiao, Yangfan
    Tang, Bingsi
    Shi, Yaqian
    Zeng, Zhuotong
    Qiu, Xiangning
    Ding, Yan
    Xiao, Rong
    AESTHETIC SURGERY JOURNAL, 2024, 44 (08) : NP574 - NP584
  • [24] Rate and Predictors of Satisfaction after Noninvasive Facial Cosmetic Procedures: A National Study in Saudi Arabia
    Alenazi, Noura Farhan
    Albattal, Nouf Z.
    Albalawi, Ibrahim Abdullah S.
    Saleh, Najla Alfateh
    Alnaim, Muna F.
    Bin Mahmoud, Asmaa Z.
    Vasilescu, D. C.
    PLASTIC AND RECONSTRUCTIVE SURGERY-GLOBAL OPEN, 2024, 12 (02) : E5607
  • [25] Spasticity after stroke: Physiology, assessment and treatment
    Thibaut, Aurore
    Chatelle, Camille
    Ziegler, Erik
    Bruno, Marie-Aurelie
    Laureys, Steven
    Gosseries, Olivia
    BRAIN INJURY, 2013, 27 (10) : 1093 - 1105
  • [26] Comparative assessment of biochemical parameters of Hariana, Hardhenu and Sahiwal breeds
    Kumar, Deepak
    Kumar, Sandeep
    Gera, Sandeep
    Yadav, Jyoti
    INDIAN JOURNAL OF ANIMAL RESEARCH, 2018, 52 (11) : 1565 - 1568
  • [27] Biogenic silica microparticles as a new and sustainable cosmetic ingredient: Assessment of performance and quality parameters
    Costa, Joana R.
    Neto, Tania
    Pedrosa, Silvia S.
    Sousa, Sergio C.
    Azevedo-Silva, Joao
    Tavares-Valente, Diana
    Mendes, Adelia
    Pintado, Manuela E.
    Fernandes, Joao C.
    Oliveira, Ana L. S.
    Madureira, Ana Raquel
    COLLOIDS AND SURFACES B-BIOINTERFACES, 2023, 226
  • [28] Effects of Dietary Supplement of Basil Extract on Biochemical and Immunological Parameters and Growth Performance in Oncorhynchus mykiss
    Noorbakhsh, Mohammad Foad
    Ghaemi, Mehran
    Gholamhosseini, Amin
    Heidari, Amir Ali
    AQUACULTURE NUTRITION, 2024, 2024
  • [29] Evaluation of the Potential Diagnostic Utility of the Determination of Selected Immunological and Molecular Parameters in Patients with Ovarian Cancer
    Englisz, Aleksandra
    Smycz-Kubanska, Marta
    Mielczarek-Palacz, Aleksandra
    DIAGNOSTICS, 2023, 13 (10)
  • [30] The impact of immunological parameters on the development of phantom pain after major amputation
    Stremmel, C
    Horn, C
    Eder, S
    Dimmler, A
    Lang, W
    EUROPEAN JOURNAL OF VASCULAR AND ENDOVASCULAR SURGERY, 2005, 30 (01) : 79 - 82