Monte Carlo-Based Radiobiological Investigation of the Most Optimal Ion Beam Forming SOBP for Particle Therapy

被引:0
作者
Kantemiris, Ioannis [1 ]
Pappas, Eleftherios P. P. [2 ]
Lymperopoulou, Georgia [3 ]
Thanasas, Dimitrios [2 ]
Karaiskos, Pantelis [2 ]
机构
[1] Metropolitan Hosp, Med Phys Dept, Neo Faliro 18547, Greece
[2] Natl & Kapodistrian Univ Athens, Med Sch, Med Phys Lab, Athens 11527, Greece
[3] Natl & Kapodistrian Univ Athens, Med Sch, Dept Radiol 1, Athens 11528, Greece
来源
JOURNAL OF PERSONALIZED MEDICINE | 2023年 / 13卷 / 01期
基金
中国国家自然科学基金;
关键词
particle therapy; ion beams; relative biological effectiveness; heavy ions; Monte Carlo; RELATIVE BIOLOGICAL EFFECTIVENESS; EFFECTIVENESS RBE; PROTON-BEAMS; FLUKA CODE; SIMULATION; C-12; HE-4; H-1; DISTRIBUTIONS; RADIOTHERAPY;
D O I
10.3390/jpm13010023
中图分类号
R19 [保健组织与事业(卫生事业管理)];
学科分类号
摘要
Proton (p) and carbon (C) ion beams are in clinical use for cancer treatment, although other particles such as He, Be, and B ions have more recently gained attention. Identification of the most optimal ion beam for radiotherapy is a challenging task involving, among others, radiobiological characterization of a beam, which is depth-, energy-, and cell type- dependent. This study uses the FLUKA and MCDS Monte Carlo codes in order to estimate the relative biological effectiveness (RBE) for several ions of potential clinical interest such as p, He-4, Li-7, Be-10, B-10, and C-12 forming a spread-out Bragg peak (SOBP). More specifically, an energy spectrum of the projectiles corresponding to a 5-cm SOBP at a depth of 8 cm was used. All secondary particles produced by the projectiles were considered and RBE was determined based on radiation-induced Double Strand Breaks (DSBs), as calculated by MCDS. In an attempt to identify the most optimal ion beam, using the latter data, biological optimization was performed and the obtained depth-dose distributions were inter-compared. The results showed that C-12 ions are more effective inside the SOBP region, which comes at the expense of higher dose values at the tail (i.e., after the SOBP). In contrast, p beams exhibit a higher DSOPB/DEntrance ratio, if physical doses are considered. By performing a biological optimization in order to obtain a homogeneous biological dose (i.e., dose x RBE) in the SOBP, the corresponding advantages of p and C-12 ions are moderated. Li-7 ions conveniently combine a considerably lower dose tail and a DSOPB/DEntrance ratio similar to C-12. This work contributes towards identification of the most optimal ion beam for cancer therapy. The overall results of this work suggest that Li-7 ions are of potential interest, although more studies are needed to demonstrate the relevant advantages. Future work will focus on studying more complex beam configurations.
引用
收藏
页数:12
相关论文
共 47 条
[1]   The FLUKA code for space applications:: recent developments [J].
Andersen, V ;
Ballarini, F ;
Battistoni, G ;
Campanella, M ;
Carboni, M ;
Cerutti, F ;
Empl, A ;
Fassó, A ;
Ferrari, A ;
Gadioli, E ;
Garzelli, MV ;
Lee, K ;
Ottolenghi, A ;
Pelliccioni, M ;
Pinsky, LS ;
Ranft, J ;
Roesler, S ;
Sala, PR ;
Wilson, TL .
SPACE LIFE SCIENCES: RADIATION RISK ASSESSMENT AND RADIATION MEASUREMENT IN LOW EARTH ORBIT, 2004, 34 (06) :1302-1310
[2]  
[Anonymous], 78 ICRU
[3]  
[Anonymous], 2008, Isotopes de l'environnement dans le cycle hydrologique, P1
[4]   Comparison of optimized single and multifield irradiation plans of antiproton, proton and carbon ion beams [J].
Bassler, Niels ;
Kantemiris, Ioannis ;
Karaiskos, Pantelis ;
Engelke, Julia ;
Holzscheiter, Michael H. ;
Petersen, Jorgen B. .
RADIOTHERAPY AND ONCOLOGY, 2010, 95 (01) :87-93
[5]  
Battistoni G., 2006, P 11 INT C NUCL REAC, P483
[6]   The FLUKA Code: An Accurate Simulation Tool For Particle Therapy [J].
Battistoni, Giuseppe ;
Bauer, Julia ;
Boehlen, Till T. ;
Cerutti, Francesco ;
Chin, Mary P. W. ;
Augusto, Ricardo Dos Santos ;
Ferrari, Alfredo ;
Ortega, Pablo G. ;
Kozlowska, Wioletta ;
Magro, Giuseppe ;
Mairani, Andrea ;
Parodi, Katia ;
Sala, Paola R. ;
Schoofs, Philippe ;
Tessonnier, Thomas ;
Vlachoudis, Vasilis .
FRONTIERS IN ONCOLOGY, 2016, 6
[7]   Overview of the FLUKA code [J].
Battistoni, Giuseppe ;
Boehlen, Till ;
Cerutti, Francesco ;
Chin, Pik Wai ;
Esposito, Luigi Salvatore ;
Fasso, Alberto ;
Ferrari, Alfredo ;
Lechner, Anton ;
Empl, Anton ;
Mairani, Andrea ;
Mereghetti, Alessio ;
Ortega, Pablo Garcia ;
Ranft, Johannes ;
Roesler, Stefan ;
Sala, Paola R. ;
Vlachoudis, Vasilis ;
Smirnov, George .
ANNALS OF NUCLEAR ENERGY, 2015, 82 :10-18
[8]   Treatment planning for volumetric modulated arc therapy [J].
Bedford, James L. .
MEDICAL PHYSICS, 2009, 36 (11) :5128-5138
[9]   A comparative study on dispersed doses during photon and proton radiation therapy in pediatric applications [J].
Beni, Mehrdad Shahmohammadi ;
Krstic, Dragana ;
Nikezic, Dragoslav ;
Yu, Kwan Ngok .
PLOS ONE, 2021, 16 (03)
[10]  
Berger M., Computer programs for calculating stopping-power and range tables for electrons, protons, and helium ions version 1.2.3