Blood Flow Turbulence Quantification of Carotid Artery with a High-Frame Rate Vector Flow Imaging

被引:11
|
作者
Dong, Yinghui [1 ,2 ]
Hong, Shaofu [1 ,2 ]
Song, Di [1 ,2 ]
Liu, Mengmeng [1 ,2 ]
Gao, Wenjing [1 ,2 ]
Du, Yigang [3 ]
Xu, Jinfeng [1 ,2 ]
Dong, Fajin [1 ,2 ]
机构
[1] Jinan Univ, Shenzhen Peoples Hosp, Clin Med Coll 2, Dept Ultrasound, Guangzhou, Peoples R China
[2] Southern Univ Sci & Technol, Affiliated Hosp 1, Shenzhen 518020, Guangdong, Peoples R China
[3] Shenzhen Mindray Biomed Elect Co Ltd, Shenzhen, Peoples R China
关键词
carotid; hemodynamics; high-frame rate ultrasound; vector flow imaging; WALL SHEAR-STRESS; VASCULAR ENDOTHELIUM; POWER DOPPLER; ICA-STENOSIS; B-FLOW; PATTERNS;
D O I
10.1002/jum.16039
中图分类号
O42 [声学];
学科分类号
070206 ; 082403 ;
摘要
Objectives To assess the feasibility and performance of Turbulence (Tur) index as a quantitative tool for carotid artery flow turbulence; to detect and compare the blood flow patterns of common carotid artery (CCA) and carotid bulb (CB) at different ages and cardiac phases in healthy adults, and thus interpret the evolvement of etiology difference between CCA and CB. Methods Carotid flow characteristics of 40 healthy volunteers were evaluated quantitatively by a high-frame rate vector flow imaging. Three types of flow patterns were defined depending on the distributive range of complex flow during systole in CB. Comparison of mean Tur value in CCA and CB at different age groups and cardiac phases was performed. And the correlation between Tur value and the diameter ratio of proximal internal carotid artery to common carotid artery (DRpro-ica/cca) was tested. Results Mean Tur values in CB were remarkably higher than that in CCA, whether during systole or diastole (P < .001). Meanwhile Tur values in CB during systole were significantly higher than that during diastole (P < .001). Flow complexity of CB showed variations among 40 participants especially in systole, whereas the flow pattern of CCA was relatively consistent. Mean Tur values were positively correlated with DRpro-ica/cca in CB (rho = 0.69, P < .05). Conclusions V Flow imaging provided a reliable method-Tur, for quantitative analysis of carotid blood flow. It had potential to be further applied in distinguishing complex hemodynamic characteristics in high-risk people of carotid diseases for the risk stratification of cardiovascular events.
引用
收藏
页码:427 / 436
页数:10
相关论文
共 50 条
  • [41] A high-frame rate duplex ultrasound biomicroscopy for small animal imaging in vivo
    Sun, Lei
    Xu, Xiaochen
    Richard, William D.
    Feng, Ching
    Johnson, Jeffrey A.
    Shung, K. Kirk
    IEEE TRANSACTIONS ON BIOMEDICAL ENGINEERING, 2008, 55 (08) : 2039 - 2049
  • [42] Frequency-domain high frame-rate 2D vector flow imaging
    Lenge, M.
    Ramalli, A.
    Boni, E.
    Cellai, A.
    Liebgott, H.
    Cachard, C.
    Tortoli, P.
    2013 IEEE INTERNATIONAL ULTRASONICS SYMPOSIUM (IUS), 2013, : 639 - 642
  • [43] HIGH-FRAME RATE POWER DOPPLER IMAGING IS MORE SENSITIVE THAN CONVENTIONAL POWER DOPPLER IN DETECTING LOW BLOOD FLOWS IN A FLOW-PHANTOM AND IN HEALTHY VOLUNTEERS
    van der Ven, M.
    Luime, J. J.
    van der Velden, L. L.
    Bosch, J. G.
    de Jong, N.
    Hazes, J. M.
    Vos, H. J.
    ANNALS OF THE RHEUMATIC DISEASES, 2016, 75 : 1232 - 1232
  • [44] Accurate Angle Estimator for High-Frame-Rate 2-D Vector Flow Imaging
    Hoyos, Carlos Armando Villagomez
    Stuart, Matthias Bo
    Hansen, Kristoffer Lindskov
    Nielsen, Michael Bachmann
    Jensen, Jorgen Arendt
    IEEE TRANSACTIONS ON ULTRASONICS FERROELECTRICS AND FREQUENCY CONTROL, 2016, 63 (06) : 842 - 853
  • [45] Utilization of singular value decomposition in high-frame-rate cardiac blood flow imaging
    Mozumi, Michiya
    Nagaoka, Ryo
    Hasegawa, Hideyuki
    JAPANESE JOURNAL OF APPLIED PHYSICS, 2019, 58
  • [46] A novel envelope detector for high-frame rate, high-frequency ultrasound imaging
    Chang, Jin Ho
    Yen, Jesse T.
    Shung, K. Kirk
    IEEE TRANSACTIONS ON ULTRASONICS FERROELECTRICS AND FREQUENCY CONTROL, 2007, 54 (09) : 1792 - 1801
  • [47] Extended high-frame rate imaging method with limited-diffraction beams
    Cheng, JQ
    Lu, JY
    IEEE TRANSACTIONS ON ULTRASONICS FERROELECTRICS AND FREQUENCY CONTROL, 2006, 53 (05) : 880 - 899
  • [48] Cerebral Blood Flow and Internal Carotid Artery Flow During Carotid Surgery
    Boysen, Gudrun
    Ladegaard-Pedersen, H. J.
    Valentin, N.
    Engell, H. C.
    STROKE, 1970, 1 (04) : 253 - 260
  • [49] Characteristics and Correlations of Wall Shear Stress and Flow Turbulence in the Carotid Bifurcation Evaluated Using an Ultrasound Vector Flow Imaging
    Liu, Mengmeng
    Song, Di
    Hong, Shaofu
    Dong, Yinghui
    Gao, Wenjing
    Du, Yigang
    Zhu, Lei
    Xu, Jinfeng
    Dong, Fajin
    JOURNAL OF VASCULAR RESEARCH, 2024, 61 (01) : 38 - 49
  • [50] 3D high frame rate flow measurement using a prototype matrix transducer for carotid imaging
    Fool, Fabian
    Vos, Hendrik J.
    Shabanimotlagh, Maysam
    Soozande, Mehdi
    Mozaffarzadeh, Moein
    Kim, Taehoon
    Kang, Eunchul
    Pertijs, Michiel
    de Jong, Nico
    Verweij, Martin D.
    2019 IEEE INTERNATIONAL ULTRASONICS SYMPOSIUM (IUS), 2019, : 2242 - 2245