Blood Flow Turbulence Quantification of Carotid Artery with a High-Frame Rate Vector Flow Imaging

被引:11
|
作者
Dong, Yinghui [1 ,2 ]
Hong, Shaofu [1 ,2 ]
Song, Di [1 ,2 ]
Liu, Mengmeng [1 ,2 ]
Gao, Wenjing [1 ,2 ]
Du, Yigang [3 ]
Xu, Jinfeng [1 ,2 ]
Dong, Fajin [1 ,2 ]
机构
[1] Jinan Univ, Shenzhen Peoples Hosp, Clin Med Coll 2, Dept Ultrasound, Guangzhou, Peoples R China
[2] Southern Univ Sci & Technol, Affiliated Hosp 1, Shenzhen 518020, Guangdong, Peoples R China
[3] Shenzhen Mindray Biomed Elect Co Ltd, Shenzhen, Peoples R China
关键词
carotid; hemodynamics; high-frame rate ultrasound; vector flow imaging; WALL SHEAR-STRESS; VASCULAR ENDOTHELIUM; POWER DOPPLER; ICA-STENOSIS; B-FLOW; PATTERNS;
D O I
10.1002/jum.16039
中图分类号
O42 [声学];
学科分类号
070206 ; 082403 ;
摘要
Objectives To assess the feasibility and performance of Turbulence (Tur) index as a quantitative tool for carotid artery flow turbulence; to detect and compare the blood flow patterns of common carotid artery (CCA) and carotid bulb (CB) at different ages and cardiac phases in healthy adults, and thus interpret the evolvement of etiology difference between CCA and CB. Methods Carotid flow characteristics of 40 healthy volunteers were evaluated quantitatively by a high-frame rate vector flow imaging. Three types of flow patterns were defined depending on the distributive range of complex flow during systole in CB. Comparison of mean Tur value in CCA and CB at different age groups and cardiac phases was performed. And the correlation between Tur value and the diameter ratio of proximal internal carotid artery to common carotid artery (DRpro-ica/cca) was tested. Results Mean Tur values in CB were remarkably higher than that in CCA, whether during systole or diastole (P < .001). Meanwhile Tur values in CB during systole were significantly higher than that during diastole (P < .001). Flow complexity of CB showed variations among 40 participants especially in systole, whereas the flow pattern of CCA was relatively consistent. Mean Tur values were positively correlated with DRpro-ica/cca in CB (rho = 0.69, P < .05). Conclusions V Flow imaging provided a reliable method-Tur, for quantitative analysis of carotid blood flow. It had potential to be further applied in distinguishing complex hemodynamic characteristics in high-risk people of carotid diseases for the risk stratification of cardiovascular events.
引用
收藏
页码:427 / 436
页数:10
相关论文
共 50 条
  • [31] Lowering the Computational Load in High Frame Rate 2-D Vector Flow Imaging
    Rossi, Stefano
    Tortoli, Piero
    Ramalli, Alessandro
    INTERNATIONAL ULTRASONICS SYMPOSIUM (IEEE IUS 2021), 2021,
  • [32] Speckle-Enhanced Cardiac Blood Flow Imaging with High Frame Rate Ultrasound
    Takahashi, Hiroki
    Hasegawa, Hideyuki
    Kanai, Hiroshi
    2013 IEEE INTERNATIONAL ULTRASONICS SYMPOSIUM (IUS), 2013, : 2030 - 2033
  • [33] High Frame Rate Vector Flow Imaging: Development as a New Diagnostic Mode on a Clinical Scanner
    Du, Yigang
    Shen, Yingying
    Yiu, Billy Y. S.
    Yu, Alfred C. H.
    Zhu, Lei
    2018 IEEE INTERNATIONAL ULTRASONICS SYMPOSIUM (IUS), 2018,
  • [34] Elasticity Imaging using conventional and high-frame rate ultrasound imaging: Experimental study
    Park, Suhyun
    Aglyamov, Salavat R.
    Emelianov, Stanislav Y.
    IEEE TRANSACTIONS ON ULTRASONICS FERROELECTRICS AND FREQUENCY CONTROL, 2007, 54 (11) : 2246 - 2256
  • [35] Intracardiac flow visualization using high-frame rate blood speckle tracking echocardiography: Illustrations from infants with congenital heart disease
    Cantinotti, Massimiliano
    Marchese, Pietro
    Koestenberger, Martin
    Giordano, Raffaele
    Santoro, Giuseppe
    Assanta, Nadia
    Kutty, Shelby
    ECHOCARDIOGRAPHY-A JOURNAL OF CARDIOVASCULAR ULTRASOUND AND ALLIED TECHNIQUES, 2021, 38 (04): : 707 - 715
  • [36] Multidirectional blood flow in the femoral artery via vector flow imaging: Doppler ultrasound imaging insights
    Cohen, Jeremy N.
    Jasiak, Jessica N.
    Nahas, Hassan
    Yu, Alfred C. H.
    Au, Jason S.
    AMERICAN JOURNAL OF PHYSIOLOGY-HEART AND CIRCULATORY PHYSIOLOGY, 2024, 327 (06): : H1467 - H1473
  • [37] BLOOD FLOW AND ELASTICITY OF CAROTID ARTERY
    Nikolov, Nikola
    Tabakova, Sonia
    Radev, Stefan
    COMPTES RENDUS DE L ACADEMIE BULGARE DES SCIENCES, 2017, 70 (11): : 1579 - 1584
  • [38] Correlation of Flow Probe Determinations of Common Carotid Artery Blood Flow and Internal Carotid Artery Blood Flow with Microsphere Determinations of Cerebral Blood Flow in Piglets
    William Meadow
    Brian Rudinsky
    Tonse Raju
    Eunice John
    Linda Fornell
    Ramarao Shankararao
    Pediatric Research, 1999, 45 : 324 - 330
  • [39] Correlation of flow probe determinations of common carotid artery blood flow and internal carotid artery blood flow with microsphere determinations of cerebral blood flow in piglets
    Meadow, W
    Rudinsky, B
    Raju, T
    John, E
    Fornell, L
    Shankararao, R
    PEDIATRIC RESEARCH, 1999, 45 (03) : 324 - 330
  • [40] A high-frame rate high-frequency ultrasonic system for cardiac imaging in mice
    Sun, Lei
    Richard, William D.
    Cannata, Jonathan M.
    Feng, Ching C.
    Johnson, Jeffrey A.
    Yen, Jesse T.
    Shung, K. Kirk
    IEEE TRANSACTIONS ON ULTRASONICS FERROELECTRICS AND FREQUENCY CONTROL, 2007, 54 (08) : 1648 - 1655