Triple-tuned birdcage and single-tuned dipole array for quadri-nuclear head MRI at 7 T

被引:0
作者
Paska, Jan [1 ,2 ]
Wang, Bili [1 ,2 ]
Chen, Anna M. [1 ,2 ]
Madelin, Guillaume [1 ,2 ]
Brown, Ryan [1 ,2 ,3 ]
机构
[1] NYU, Ctr Adv Imaging Innovat & Res, Grossman Sch Med, Dept Radiol, New York, NY USA
[2] NYU, Grossman Sch Med, Bernard & Irene Schwartz Ctr Biomed Imaging, Dept Radiol, New York, NY USA
[3] Ctr Biomed Imaging, Dept Radiol, 660 First Ave,4th Floor, New York, NY 10016 USA
关键词
deuterium-H-2; MRI; phosphorus-P-31; MRSI; sodium-Na-23; simultaneous multi-nuclear MRI; ultrahigh field MRI; BRAIN ENERGY-METABOLISM; MAGNETIC-RESONANCE-SPECTROSCOPY; TRAP DESIGN; SODIUM MRI; RF COIL; P-31; QUADRATURE; H-1;
D O I
10.1002/mrm.29977
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose: The purpose of this work was to design and build a coil for quadri-nuclear MRI of the human brain at 7 T.Methods: We built a transmit/receive triple-tuned (45.6 MHz for H-2, 78.6 MHz for Na-23, and 120.3 MHz for P-31) quadrature four-rod birdcage that was geometrically interleaved with a transmit/receive four-channel dipole array (297.2 MHz for 1H). The birdcage rods contained passive, two-pole resonant circuits that emulated capacitors required for single-tuning at three frequencies. The birdcage assembly also included triple-tuned matching networks, baluns, and transmit/receive switches. We assessed the performance of the coil with quality factor (Q) and signal-to-noise ratio (SNR) measurements, and performed in vivo multinuclear MRI and MR spectroscopic imaging (MRSI).Results: Q measurements showed that the triple-tuned birdcage efficiency was within 33% of that of single-tuned baseline birdcages at all three frequencies. The quadri-tuned coil SNR was 78%, 59%, 44%, and 48% lower than that of single or dual-tuned reference coils for H-1, H-22, Na-23, and 3131 P, respectively. Quadri-nuclear MRI and MRSI was demonstrated in brain in vivo in about 30 min.Conclusion: While the SNR of the quadruple tuned coil was significantly lower than dual- and single-tuned reference coils, it represents a step toward truly simultaneous quadri-nuclear measurements.
引用
收藏
页码:2188 / 2199
页数:12
相关论文
共 58 条
  • [1] Triheptanoin improves brain energy metabolism in patients with Huntington disease
    Adanyeguh, Isaac Mawusi
    Rinaldi, Daisy
    Henry, Pierre-Gilles
    Caillet, Samantha
    Valabregue, Romain
    Durr, Alexandra
    Mochel, Fanny
    [J]. NEUROLOGY, 2015, 84 (05) : 490 - 495
  • [2] A half-volume coil for efficient proton decoupling in humans at 4 Tesla
    Adriany, G
    Gruetter, R
    [J]. JOURNAL OF MAGNETIC RESONANCE, 1997, 125 (01) : 178 - 184
  • [3] THRESHOLDS IN CEREBRAL-ISCHEMIA - THE ISCHEMIC PENUMBRA
    ASTRUP, J
    SIESJO, BK
    SYMON, L
    [J]. STROKE, 1981, 12 (06) : 723 - 725
  • [4] Double-tuned 31P/1H human head array with high performance at both frequencies for spectroscopic imaging at 9.4T
    Avdievich, Nikolai, I
    Ruhm, Loreen
    Dorst, Johanna
    Scheffler, Klaus
    Korzowski, Andreas
    Henning, Anke
    [J]. MAGNETIC RESONANCE IN MEDICINE, 2020, 84 (02) : 1076 - 1089
  • [5] Brain Energy Metabolism: Focus on Astrocyte-Neuron Metabolic Cooperation
    Belanger, Mireille
    Allaman, Igor
    Magistretti, Pierre J.
    [J]. CELL METABOLISM, 2011, 14 (06) : 724 - 738
  • [6] Loss of cell ion homeostasis and cell viability in the brain: What sodium MRI can tell us
    Boada, FE
    LaVerde, G
    Jungreis, C
    Nemoto, E
    Tanase, C
    Hancu, F
    [J]. CURRENT TOPICS IN DEVELOPMENTAL BIOLOGY, VOLUME 70, 2005, 70 : 77 - +
  • [7] PROTON-DECOUPLED, OVERHAUSER-ENHANCED, SPATIALLY LOCALIZED C-13 SPECTROSCOPY IN HUMANS
    BOTTOMLEY, PA
    HARDY, CJ
    ROEMER, PB
    MUELLER, OM
    [J]. MAGNETIC RESONANCE IN MEDICINE, 1989, 12 (03) : 348 - 363
  • [8] Magnetic Resonance Imaging of Phosphocreatine and Determination of BOLD Kinetics in Lower Extremity Muscles using a Dual-Frequency Coil Array
    Brown, Ryan
    Khegai, Oleksandr
    Parasoglou, Prodromos
    [J]. SCIENTIFIC REPORTS, 2016, 6
  • [9] A nested phosphorus and proton coil array for brain magnetic resonance imaging and spectroscopy
    Brown, Ryan
    Lakshmanan, Karthik
    Madelin, Guillaume
    Parasoglou, Prodromos
    [J]. NEUROIMAGE, 2016, 124 : 602 - 611
  • [10] Busher J., 2023, CONCEPT MAGNETIC RES, V2023, P1