Importance of Pattern Standard Deviation of Humphrey 10-2 Visual Field to Evaluate Central Visual Function in Patients with Early-Stage Glaucoma

被引:3
|
作者
Shin, Hee Jong [1 ]
Oh, Si Eun [1 ]
Park, Chan Kee [1 ]
Park, Hae-Young Lopilly [1 ]
机构
[1] Catholic Univ Korea, Seoul St Marys Hosp, Coll Med, Dept Ophthalmol, Seoul 06591, South Korea
关键词
glaucoma suspect; normal tension glaucoma; perimetry; pattern standard deviation; pattern electroretinogram; INNER PLEXIFORM LAYER; NERVE-FIBER LAYER; PERIMETRY; DEFECTS; DAMAGE; GRIDS;
D O I
10.3390/jcm12155091
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
To explore various parameters that can evaluate the central visual impairment in patients with early-stage glaucoma, we included patients into a study with central visual impairments with an MD value greater than -6.0 dB on the 24-2 VF test. A possible association between structural parameters acquired by OCT and functional parameters of VF and PERG was determined. A total of 70 eyes of patients with suspected glaucoma or NTG underwent VF, OCT, and PERG examinations. The patients were classified into two groups according to the MD of the 24-2 VF test. We used Pearson correlation analysis to evaluate the relationships between GCIPL thickness/RNFL thickness and visual functional parameters, such as PERG and perimetry. Linear regression analyses were conducted to evaluate the significant factors affecting the PSD of VF 10-2. In the low MD group, the P50 amplitude presented significant correlations (r = 0.346, p = 0.048) with GCIPL thickness. In the correlation analysis of the high MD group, it was found that only the PSD of 10-2 uniquely presented borderline significant correlations with GCIPL thickness (r = -0.327, p = 0.055), and no other functional parameter showed significant correlation. Univariate and multivariate analyses revealed that GCIPL thickness was significantly associated with a PSD of 10-2 VF (p < 0.001 and 0.013, respectively). Among various parameters, the P50 amplitude and 10-2 PSD demonstrated statistically borderline significant structure-function relationships with GCIPL thickness in early-stage glaucoma.
引用
收藏
页数:11
相关论文
共 46 条
  • [31] Association Between Undetected 10-2 Visual Field Damage and Vision-Related Quality of Life in Patients With Glaucoma
    Blumberg, Dana M.
    De Moraes, Carlos Gustavo
    Prager, Alisa J.
    Yu, Qi
    Al-Aswad, Lama
    Cioffi, George A.
    Liebmann, Jeffrey M.
    Hood, Donald C.
    JAMA OPHTHALMOLOGY, 2017, 135 (07) : 742 - 747
  • [32] Agreement Between 10-2 and 24-2C Visual Field Test Protocols for Detecting Glaucomatous Central Visual Field Defects
    Chakravarti, Tutul
    Moghadam, Mohamad
    Proudfoot, James A.
    Weinreb, Robert N.
    Bowd, Christopher
    Zangwill, Linda M.
    JOURNAL OF GLAUCOMA, 2021, 30 (06) : E285 - E291
  • [33] Values of macular ganglion cell-inner plexiform layer and 10-2 visual field measurements in detecting and evaluating glaucoma
    Hu, Hai-Jian
    Li, Ping
    Tong, Bin
    Pang, Yu-Lian
    Luo, Hong-Dou
    Wang, Fei-Fei
    Xiong, Chan
    Yu, Yu-Lin
    He, Hai
    Zhang, Xu
    INTERNATIONAL JOURNAL OF OPHTHALMOLOGY, 2024, 17 (05) : 852 - 860
  • [34] Predicting 10-2 Visual Field From Optical Coherence Tomography in Glaucoma Using Deep Learning Corrected With 24-2/30-2 Visual Field
    Hashimoto, Yohei
    Kiwaki, Taichi
    Sugiura, Hiroki
    Asano, Shotaro
    Murata, Hiroshi
    Fujino, Yuri
    Matsuura, Masato
    Miki, Atsuya
    Mori, Kazuhiko
    Ikeda, Yoko
    Kanamoto, Takashi
    Yamagami, Junkichi
    Inoue, Kenji
    Tanito, Masaki
    Yamanishi, Kenji
    Asaoka, Ryo
    TRANSLATIONAL VISION SCIENCE & TECHNOLOGY, 2021, 10 (13):
  • [35] Modifying the Conventional Visual Field Test Pattern to Improve the Detection of Early Glaucomatous Defects in the Central 10°
    Ehrlich, Alyssa C.
    Raza, Ali S.
    Ritch, Robert
    Hood, Donald C.
    TRANSLATIONAL VISION SCIENCE & TECHNOLOGY, 2014, 3 (06):
  • [36] Commentary: Rethinking 10-2 visual fields in early diagnosis of glaucoma for a glided glaucoma practice: The right choice to pick up a feeble noise?
    Ramesh, Prasanna, V
    Devadas, Aji K.
    Kumar, Niranjan K. S.
    Sainath, Dipika
    INDIAN JOURNAL OF OPHTHALMOLOGY, 2023, 71 (03) : 860 - 863
  • [37] The glaucoma detection capability of spectral-domain OCT and GDx-VCC deviation maps in early glaucoma patients with localized visual field defects
    Na, Jung Hwa
    Lee, Kyoung Sub
    Lee, Jong Rak
    Lee, Youngrok
    Kook, Michael S.
    GRAEFES ARCHIVE FOR CLINICAL AND EXPERIMENTAL OPHTHALMOLOGY, 2013, 251 (10) : 2371 - 2382
  • [38] Longitudinal Structure-Function Relationship between Macular Vessel Density and Thickness and Central Visual Field in Early Glaucoma
    Mohammadzadeh, Vahid
    Moghimi, Sasan
    Nishida, Takashi
    Proudfoot, James A.
    Eslani, Medi
    Kamalipour, Alireza
    El-Nimri, Nevin
    Micheletti, Eleonora
    Zangwill, Linda M.
    Weinreb, Robert N.
    OPHTHALMOLOGY GLAUCOMA, 2022, 5 (06): : 648 - 657
  • [39] Inter/Intra-Observer Agreement to Detect Glaucomatous Visual Field Progression by Using Standard Humphrey Printout, Glaucoma Progression Analysis 1 and 2
    Iester, M. M.
    Capris, E.
    De Feo, F.
    Brusini, P.
    Corallo, G.
    Figus, M.
    Fogagnolo, P.
    Frezzotti, P.
    Manni, G.
    Perdicchi, A.
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2010, 51 (13)
  • [40] Utility of Central 10 Degrees Visual Field Test With Size V Stimulus in End-Stage Glaucoma
    Hwang, Young Hoon
    JOURNAL OF GLAUCOMA, 2023, 32 (12) : 1022 - 1028