Comparative studies of plastic scintillator strips with high technical attenuation length for the total-body J-PET scanner

被引:7
|
作者
Kaplon, L. [1 ,2 ,3 ]
Baran, J. [1 ,2 ,3 ]
Chug, N. [1 ,2 ,3 ]
Coussat, A. [1 ,2 ,3 ]
Curceanu, C. [4 ]
Czerwinski, E. [1 ,2 ,3 ]
Dadgar, M. [1 ,2 ,3 ]
Dulski, K. [1 ,2 ,3 ]
Gajewski, J. [5 ]
Gajos, A. [1 ,2 ,3 ]
Hiesmayr, B. [6 ,8 ]
Valsan, E. Kavya [1 ,2 ,3 ]
Klimaszewski, K. [7 ]
Korcyl, G. [1 ,2 ,3 ]
Kozik, T. [1 ]
Krzemien, W. [2 ,3 ,8 ]
Kumar, D. [1 ,2 ,3 ]
Moskal, G. [2 ,3 ,9 ]
Niedzwiecki, S. [1 ,2 ,3 ]
Panek, D. [1 ,2 ,3 ]
Parzych, S. [1 ,2 ,3 ]
del Rio, E. Perez [1 ,2 ,3 ]
Raczynski, L. [7 ]
Rucinski, A. [5 ]
Sharma, S. [1 ,2 ,3 ]
Shivani, S. [1 ,2 ,3 ]
Shopa, R. [7 ]
Silarski, M. [1 ,2 ,3 ]
Skurzok, M. [1 ,2 ,3 ]
Stepien, E. [1 ,2 ,3 ]
Ardebili, F. Tayefi [1 ,2 ,3 ]
Ardebili, K. Tayefi [1 ,2 ,3 ]
Wislicki, W. [7 ]
Moskal, P. [1 ,2 ,3 ]
机构
[1] Jagiellonian Univ, Fac Phys Astron & Appl Comp Sci, Lojasiewicza 11, PL-30348 Krakow, Poland
[2] Jagiellonian Univ, Total Body Jagiellonian PET Lab, Lojasiewicza 11, PL-30348 Krakow, Poland
[3] Jagiellonian Univ, Ctr Theranost, Krakow, Poland
[4] INFN, Lab Nazl Frascati, I-00044 Frascati, Italy
[5] Inst Nucl Phys, Polish Acad Sci, Radzikowskiego 152, PL-31342 Krakow, Poland
[6] Univ Vienna, Fac Phys, A-1090 Vienna, Austria
[7] Natl Ctr Nucl Res, Dept Complex Syst, PL-05400 Otwock, Poland
[8] Natl Ctr Nucl Res, High Energy Phys Div, PL-05400 Otwock, Poland
[9] Jagiellonian Univ, Fac Chem, Gronostajowa 2, PL-30387 Krakow, Poland
关键词
Plastic scintillator; Technical attenuation length; Transmission spectra; Emission spectra; Total-body J-PET; Medical imaging; 3 M LONG;
D O I
10.1016/j.nima.2023.168186
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
Plastic scintillator strips are considered as one of the promising solutions for the cost-effective construction of total-body positron emission tomography, (PET) system. The purpose of the performed measurements is to compare the transparency of long plastic scintillators with dimensions 6 mm x 24 mm x 1000 mm and with all surfaces polished. Six different types of commercial, general purpose, blue-emitting plastic scintillators with low attenuation of visible light were tested, namely: polyvinyl toluene-based BC-408, EJ-200, RP-408, and polystyrene-based Epic, SP32 and UPS-923A. For determination of the best type of plastic scintillator for total -body Jagiellonian positron emission tomograph (TB-J-PET) construction, emission and transmission spectra, and technical attenuation length (TAL) of blue light-emitting by the scintillators were measured and compared. The TAL values were determined with the use of UV lamp as excitation source, and photodiode as light detector. Emission spectra of investigated scintillators have maxima in the range from 420 nm to 429 nm. The BC-408 and EJ-200 have the highest transmittance values of about 90% at the maximum emission wavelength measured through a 6 mm thick scintillator strip and the highest technical attenuation length reaching about 2000 mm, allowing assembly of long detection modules for time-of-flight (TOF) J-PET scanners. Influence of the 6 mm x 6 mm, 12 mm x 6 mm, 24 mm x 6 mm cross-sections of the 1000 mm long EJ-200 plastic scintillator on the TAL and signal intensity was measured. The highest TAL value was determined for samples with 24 mm x 6 mm cross-section.
引用
收藏
页数:10
相关论文
共 17 条
  • [11] A Simulation Study to Estimate Optimum LOR Angular Acceptance for the Image Reconstruction with the Total-Body J-PET
    Dadgar, Meysam
    Parzych, Szymon
    Ardebili, Faranak Tayefi
    MEDICAL IMAGE UNDERSTANDING AND ANALYSIS (MIUA 2021), 2021, 12722 : 189 - 200
  • [12] ESTIMATION OF 511 keV GAMMA SCATTER FRACTION IN WLS LAYER IN TOTAL-BODY J-PET; A SIMULATION STUDY
    Ardebili, K. Tayefi
    Niedzwiecki, S.
    Moskal, P.
    ACTA PHYSICA POLONICA B PROCEEDINGS SUPPLEMENT, 2022, 15 (04)
  • [13] Optimisation of the event-based TOF filtered back-projection for online imaging in total-body J-PET
    Shopa, R. Y.
    Klimaszewski, K.
    Kopka, P.
    Kowalski, P.
    Krzemien, W.
    Raczynski, L.
    Wislicki, W.
    Chug, N.
    Curceanu, C.
    Czerwinski, E.
    Dadgar, M.
    Dulski, K.
    Gajos, A.
    Hiesmayr, B. C.
    Kacprzak, K.
    Kaplon, L.
    Kisielewska, D.
    Korcyl, G.
    Krawczyk, N.
    Kubicz, E.
    Niedzwiecki, Sz
    Raj, J.
    Sharma, S.
    Shivani
    Stepien, E. L.
    Tayefi, F.
    Moskal, P.
    MEDICAL IMAGE ANALYSIS, 2021, 73
  • [14] Comparative studies of the sensitivities of sparse and full geometries of Total-Body PET scanners built from crystals and plastic scintillators
    M. Dadgar
    S. Parzych
    J. Baran
    N. Chug
    C. Curceanu
    E. Czerwiński
    K. Dulski
    K. Elyan
    A. Gajos
    B. C. Hiesmayr
    Ł. Kapłon
    K. Klimaszewski
    P. Konieczka
    G. Korcyl
    T. Kozik
    W. Krzemien
    D. Kumar
    S. Niedzwiecki
    D. Panek
    E. Perez del Rio
    L. Raczyński
    S. Sharma
    S. Shivani
    R. Y. Shopa
    M. Skurzok
    E. Ł. Stepień
    F. Tayefi Ardebili
    K. Tayefi Ardebili
    S. Vandenberghe
    W. Wiślicki
    P. Moskal
    EJNMMI Physics, 10
  • [15] Comparative studies of the sensitivities of sparse and full geometries of Total-Body PET scanners built from crystals and plastic scintillators
    Dadgar, M.
    Parzych, S.
    Baran, J.
    Chug, N.
    Curceanu, C.
    Czerwinski, E.
    Dulski, K.
    Elyan, K.
    Gajos, A.
    Hiesmayr, B. C.
    Kaplon, L.
    Klimaszewski, K.
    Konieczka, P.
    Korcyl, G.
    Kozik, T.
    Krzemien, W.
    Kumar, D.
    Niedzwiecki, S.
    Panek, D.
    Perez del Rio, E.
    Raczynski, L.
    Sharma, S.
    Shivani, S.
    Shopa, R. Y.
    Skurzok, M.
    Stepien, E. L.
    Tayefi Ardebili, F.
    Tayefi Ardebili, K.
    Vandenberghe, S.
    Wislicki, W.
    Moskal, P.
    EJNMMI PHYSICS, 2023, 10 (01)
  • [16] 3Dπ: three-dimensional positron imaging, a novel total-body PET scanner using xenon-doped liquid argon scintillator
    Zabihi, Azam
    Li, Xinran
    Ramirez, Alejandro
    Ahmad, Iftikhar
    Rolo, Manuel D. Da Rocha
    Franco, Davide
    Gabriele, Federico
    Galbiati, Cristiano
    Lai, Michela
    Marlow, Daniel R.
    Renshaw, Andrew
    Westerdale, Shawn
    Wada, Masayuki
    PHYSICS IN MEDICINE AND BIOLOGY, 2025, 70 (06):
  • [17] A comparative study regarding deep inhalation breath-hold and free-breathing PET/CT using total-body PET scanner in thoracic diseases
    Cui, Yingpu
    Jia, Jin
    He, Xiaoxiao
    Yan, Qianqian
    Yuan, Keqing
    Tang, Si
    Zheng, Chaojie
    Fan, Wei
    Zhang, Wei-Guang
    Zhao, Yumo
    Hu, Ying-Ying
    JOURNAL OF NUCLEAR MEDICINE, 2023, 64