A validated UPLC-MS/MS assay of E7090, a novel selective inhibitor of fibroblast growth factor receptors, in human plasma and urine

被引:2
|
作者
Asakawa, Yoshiki [1 ]
Sano, Takuya [1 ]
Hotta, Koichiro [2 ]
Miyajima, Yukiko [2 ]
Mano, Yuji [2 ,3 ]
机构
[1] Sunplanet Co Ltd, Tsukuba R&D Supporting Div, DMPK & Bioanal Unit, Tokodai 5-1-3, Tsukuba, Ibaraki 3002635, Japan
[2] Eisai & Co Ltd, Drug Metab & Pharmacokinet, Biopharmaceut Assessment Core Funct Unit, Tokodai 5-1-3, Tsukuba, Ibaraki 3002635, Japan
[3] Univ Tsukuba, Fac Med, Grad Sch Comprehens Human Sci, Lab Genom Based Drug Discovery, Tennodai 1-1-1, Tsukuba, Ibaraki 3058575, Japan
关键词
E7090; Validation; Human; Plasma; Urine; IDENTIFICATION;
D O I
10.1016/j.jpba.2022.115216
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
E7090, a novel fibroblast growth factor receptors inhibitor, is currently under clinical development for the treatment of patients with solid tumors. Assays for the determination of E7090 concentrations in human plasma and urine have been developed using ultra-performance liquid chromatography-tandem mass spectrometry (UPLC-MS/MS) to evaluate pharmacokinetic profiles of E7090. E7090 and a deuterated labeled internal standard (IS) were extracted from 50 mu L of plasma by protein precipitation. In quantification of E7090 in urine, 50 mu L of urine samples fortified with 15 mu L of ethanol (10:3, v/v) to minimize nonspecific binding of E7090 to urine containers were subjected to the assay without extraction. E7090 and the IS were separated by chromatography on a reverse phase column and were detected by selected reaction monitoring in the positive ion mode. The lower limit of quantification was set at 1 ng/mL and E7090 was quantifiable from 1 to 3000 ng/mL in plasma and urine. Accuracy and precision were measured during the reproducibility assessments and were within +/- 7.0% and 9.1%, respectively, in plasma and within +/- 7.0% and 5.8%, respectively, in urine, indicating sufficient reproducibility. The validated methods were successfully applied to the quantification of E7090 in human plasma and urine to support a Phase-1 clinical trial.
引用
收藏
页数:9
相关论文
共 29 条
  • [1] A sensitive assay for the determination of E7090, a novel selective inhibitor of fibroblast growth factor receptors, and its metabolite in human plasma by UPLC-MS/MS with at-column dilution
    Mano, Yuji
    Nitanai, Ikumi
    Hotta, Koichiro
    JOURNAL OF PHARMACEUTICAL AND BIOMEDICAL ANALYSIS, 2024, 238
  • [2] Quantitative bioanalytical assay for the human epidermal growth factor receptor (HER) inhibitor dacomitinib in rat plasma by UPLC-MS/MS
    Qiu, Xiangjun
    Lin, Qianmeng
    Ning, Zongdi
    Qian, Xin
    Li, Pengbo
    Ye, Lei
    Xie, Saili
    JOURNAL OF PHARMACEUTICAL AND BIOMEDICAL ANALYSIS, 2019, 166 : 66 - 70
  • [3] UPLC-MS/MS Method for the Identification of Recombinant Human Erythropoietin Analogues in Horse Plasma and Urine
    Scarth, James P.
    Seibert, Cathrin
    Brown, Pamela R.
    Teale, Phil
    Beamon, Gavin J.
    Pearce, Clive M.
    Sams, Richard A.
    CHROMATOGRAPHIA, 2011, 74 (7-8) : 593 - 608
  • [4] UPLC-MS/MS Method for the Identification of Recombinant Human Erythropoietin Analogues in Horse Plasma and Urine
    James P. Scarth
    Cathrin Seibert
    Pamela R. Brown
    Phil Teale
    Gavin J. Beamon
    Clive M. Pearce
    Richard A. Sams
    Chromatographia, 2011, 74 : 593 - 608
  • [5] A validated UPLC-MS/MS assay for the quantification of amino acids and biogenic amines in rat urine
    Gray, Nicola
    Plumb, Robert S.
    Wilson, Ian D.
    Nicholson, Jeremy K.
    JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2019, 1106 : 50 - 57
  • [6] Development and validation of a UPLC-MS/MS assay for the quantification of simotinib in human plasma
    Li, Ning
    Han, Xiaohong
    Du, Ping
    Song, Yuanyuan
    Hu, Xingsheng
    Yang, Sheng
    Shi, Yuankai
    ANALYTICAL AND BIOANALYTICAL CHEMISTRY, 2014, 406 (06) : 1799 - 1805
  • [7] A rapid UPLC-MS/MS assay for eicosanoids in human plasma: Application to evaluate niacin responsivity
    Miller, Tricia M.
    Poloyac, Samuel M.
    Anderson, Kacey B.
    Waddell, Brooke L.
    Messamore, Erik
    Yao, Jeffrey K.
    PROSTAGLANDINS LEUKOTRIENES AND ESSENTIAL FATTY ACIDS, 2018, 136 : 153 - 159
  • [8] Novel and sensitive UPLC-MS/MS method for quantification of sofosbuvir in human plasma: application to a bioequivalence study
    Rezk, Mamdouh R.
    Basalious, Emad B.
    Amin, Mohammed E.
    BIOMEDICAL CHROMATOGRAPHY, 2016, 30 (09) : 1354 - 1362
  • [9] UPLC-MS/MS Method for the Quantification of a Novel Non-Steroidal Androgen Receptor Inhibitor Apalutamide in Rat Plasma
    Wang, Qiong
    Zhong, Youyan
    Wang, Haiyun
    Xiang, Yun
    LATIN AMERICAN JOURNAL OF PHARMACY, 2019, 38 (12): : 2339 - 2344
  • [10] Simultaneous quantification of mycophenolic acid and its glucuronide metabolites in human plasma by an UPLC-MS/MS assay
    Zhang, Daping
    Chow, Diana S-L.
    Renbarger, Jamie L.
    BIOMEDICAL CHROMATOGRAPHY, 2016, 30 (10) : 1648 - 1655