Balloon-expandable transcatheter heart valves for treatment of aortic valve stenosis in patients with large aortic annuli: Evaluation of deployment balloon overfilling strategies

被引:0
作者
Schneeberger, Yvonne [1 ]
Sarwari, Harun [1 ]
Koell, Benedikt [2 ]
Demal, Till J. [1 ]
Bhadra, Oliver D. [1 ]
von der Heide, Ina [2 ]
Hannen, Laura [2 ]
Grundmann, David [2 ]
Voigtlaender, Lisa [2 ]
Waldschmidt, Lara [2 ]
Schirmer, Johannes [1 ]
Pecha, Simon [1 ]
Schofer, Niklas [2 ]
Soerensen, Nils [2 ]
Blankenberg, Stefan [2 ]
Reichenspurner, Hermann [1 ]
Conradi, Lenard [1 ]
Seiffert, Moritz [2 ]
Schaefer, Andreas [1 ,3 ]
机构
[1] Univ Heart & Vasc Ctr Hamburg, Dept Cardiovasc Surg, Hamburg, Germany
[2] Univ Heart & Vasc Ctr Hamburg, Dept Cardiol, Hamburg, Germany
[3] Univ Heart & Vasc Ctr Hamburg, Dept Cardiovasc Surg, Martinistr 52, D-20246 Hamburg, Germany
关键词
aortic annulus; aortic valve stenosis; balloon expandable; transcatheter aortic valve implantation; transcatheter heart valve; IMPACT; CALCIFICATION; IMPLANTATION; REPLACEMENT; OUTCOMES;
D O I
10.1002/ccd.30922
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Objectives Transcatheter aortic valve implantation (TAVI) using balloon-expandable (BE) transcatheter heart valves (THV) in aortic annuli above 29 mm includes particular procedural steps, mainly involving overfilling of the deployment balloon. Data on overfilling strategies in clinical daily practice is scarce. We herein aimed for a retrospective description of utilized overfilling strategies in those patients.Methods Between January 2016 and December 2022, 45 patients (100% male, 76.9 +/- 6.1 years) received TAVI in aortic annuli above 29 mm using a BE THV. Overfilling volumina of the deployment balloon were left to operators' discretion. Clinical and multislice computed tomography data were retrospectively collected. Clinical endpoints were adjudicated in accordance with the updated standardized VARC-3 definitions.Results Profound overfilling (+4/5 mL) was used in patients with a mild calcium burden (<750 mm(3)) even in aortic annuli of 29.0-30.0 mm. Nominal/slight overfilling (+1 mL) was used in aortic annuli up to 32.5 mm but an intermediate to severe calcific burden (>750-3200 mm(3)). Accordingly, a low calcification group (<750 mm(3), n = 17) compared to a significant calcification group (>= 750 mm(3), n = 28), presented with higher overfilling volumina (2.1 +/- 1.4 vs. 0.8 +/- 1.0; p < 0.001), although aortic annulus diameter was not different (29.8 +/- 0.8 vs. 29.9 +/- 0.9 mm; p = 0.7). All-cause 30-day mortality was 0%. Device success was 97.8%. Transvalvular mean pressure gradient at discharge was 9.5 +/- 3.6 mmHg. No case of PVL >mild was documented.Conclusion Extent of overfilling of the deployment balloon largely depends on calcification burden in addition to aortic annulus diameter with significant and profound overfilling particularly in patients with a calcification burden of the aortic valve complex <750 mm(3).
引用
收藏
页码:194 / 201
页数:8
相关论文
共 50 条
[41]   Prosthesis-patient mismatch after transcatheter implantation of contemporary balloon-expandable and self-expandable valves in small aortic annuli [J].
Leone, Pier Pasquale ;
Regazzoli, Damiano ;
Pagnesi, Matteo ;
Costa, Giuliano ;
Teles, Rui ;
Adamo, Marianna ;
Taramasso, Maurizio ;
De Marco, Federico ;
Mangieri, Antonio ;
Kargoli, Faraj ;
Ohno, Yohei ;
Saia, Francesco ;
Ielasi, Alfonso ;
Ribichini, Flavio ;
Maffeo, Diego ;
Kim, Won-Keun ;
Maisano, Francesco ;
Van Mieghem, Nicolas M. ;
Colombo, Antonio ;
Reimers, Bernhard ;
Latib, Azeem .
CATHETERIZATION AND CARDIOVASCULAR INTERVENTIONS, 2023, 102 (05) :931-943
[42]   A novel balloon-expandable transcatheter aortic valve bioprosthesis: Myval and Myval Octacor [J].
Montonati, Carolina ;
Pellegrini, Dario ;
d'Atri, Daniele Oreste ;
Pellicano, Mariano ;
Briguglia, Daniele ;
Giannini, Francesco ;
De Blasio, Giuseppe ;
Guagliumi, Giulio ;
Tespili, Maurizio ;
Ielasi, Alfonso .
EXPERT REVIEW OF CARDIOVASCULAR THERAPY, 2024, 22 (07) :325-337
[43]   Transcatheter Aortic Valve Implantation with balloon-expandable valve in low-flow low-gradient severe aortic stenosis in Nepal [J].
Adhikari, Chandra Mani ;
Timalsena, Birat Krishna ;
Bogati, Amrit ;
Khan, Barkadin ;
Acharya, Anjana ;
Ghimire, Vijay ;
Mehta, Kshitij ;
Prajapati, Dipanker .
NEPALESE HEART JOURNAL, 2023, 20 (01) :49-52
[44]   Computational Analysis of Self-Expanding and Balloon-Expandable Transcatheter Heart Valves [J].
Pasta, Salvatore ;
Gandolfo, Caterina .
BIOMECHANICS, 2021, 1 (01) :43-52
[45]   Balloon-expandable transaortic transcatheter aortic valve implantation with or without predilation [J].
Bonaros, Nikolaos ;
Kofler, Markus ;
Frank, Derk ;
Cocchieri, Riccardo ;
Jagielak, Dariusz ;
Aiello, Marco ;
Lapeze, Joel ;
Laine, Mika ;
Chocron, Sidney ;
Muir, Douglas ;
Eichinger, Walter ;
Thielmann, Matthias ;
Labrousse, Louis ;
Bapat, Vinayak ;
Rein, Kjell Arne ;
Verhoye, Jean-Philippe ;
Gerosa, Gino ;
Baumbach, Hardy ;
Deutsch, Cornelia ;
Bramlage, Peter ;
Thoenes, Martin ;
Romano, Mauro .
JOURNAL OF THORACIC AND CARDIOVASCULAR SURGERY, 2018, 155 (03) :915-923
[46]   Results of new-generation balloon vs. self-expandable transcatheter heart valves for bicuspid aortic valve stenosis [J].
Deutsch, Oliver ;
Vitanova, Keti ;
Ruge, Hendrik ;
Erlebach, Magdalena ;
Krane, Markus ;
Lange, Ruediger .
FRONTIERS IN CARDIOVASCULAR MEDICINE, 2023, 10
[47]   Transcatheter Aortic Valve Replacement With Balloon-Expandable Valves Comparison of SAPIEN 3 Ultra Versus SAPIEN 3 [J].
Rheude, Tobias ;
Pellegrini, Costanza ;
Lutz, Jannik ;
Alvarez-Covarrubias, Hector A. ;
Lahmann, Anna Lena ;
Mayr, N. Patrick ;
Michel, Jonathan ;
Kasel, Markus A. ;
Joner, Michael ;
Xhepa, Erion .
JACC-CARDIOVASCULAR INTERVENTIONS, 2020, 13 (22) :2631-2638
[48]   Aortic regurgitation with second versus third-generation balloon-expandable prostheses in patients undergoing transcatheter aortic valve implantation [J].
Jochheim, David ;
Zadrozny, Magda ;
Theissl, Hans ;
Baquet, Moritz ;
Maimer-Rodrigues, Fatima ;
Bauer, Axel ;
Lange, Philipp ;
Greif, Martin ;
Kupatt, Christian ;
Hausleiter, Joerg ;
Hagl, Christian ;
Massberg, Steffen ;
Mehilli, Julinda .
EUROINTERVENTION, 2015, 11 (02) :214-220
[49]   Quantitative Angiographic Assessment of Aortic Regurgitation after Transcatheter Aortic Valve Implantation among Three Balloon-Expandable Valves [J].
Kawashima, Hideyuki ;
Wang, Rutao ;
Mylotte, Darren ;
Jagielak, Dariusz ;
De Marco, Frederico ;
Ielasi, Alfonso ;
Onuma, Yoshinobu ;
den Heijer, Peter ;
Terkelsen, Christian Juhl ;
Wijns, William ;
Serruys, Patrick W. ;
Soliman, Osama .
GLOBAL HEART, 2021, 16 (01)
[50]   Clinical Impact of Intraventricular Conduction Abnormalities After Transcatheter Aortic Valve Implantation With Balloon-Expandable Valves [J].
Miura, Mizuki ;
Shirai, Shinichi ;
Uemura, Yukari ;
Hayashi, Masaomi ;
Takiguchi, Hiroshi ;
Ito, Shinya ;
Yano, Mariko ;
Kawaguchi, Tomohiro ;
Morinaga, Takashi ;
Isotani, Akihiro ;
Kakumoto, Shinichi ;
Seo, Katsuhiro ;
Arai, Yoshio ;
Sakaguchi, Genichi ;
Ando, Kenji .
AMERICAN JOURNAL OF CARDIOLOGY, 2019, 123 (02) :297-305