Balloon-expandable transcatheter heart valves for treatment of aortic valve stenosis in patients with large aortic annuli: Evaluation of deployment balloon overfilling strategies

被引:0
作者
Schneeberger, Yvonne [1 ]
Sarwari, Harun [1 ]
Koell, Benedikt [2 ]
Demal, Till J. [1 ]
Bhadra, Oliver D. [1 ]
von der Heide, Ina [2 ]
Hannen, Laura [2 ]
Grundmann, David [2 ]
Voigtlaender, Lisa [2 ]
Waldschmidt, Lara [2 ]
Schirmer, Johannes [1 ]
Pecha, Simon [1 ]
Schofer, Niklas [2 ]
Soerensen, Nils [2 ]
Blankenberg, Stefan [2 ]
Reichenspurner, Hermann [1 ]
Conradi, Lenard [1 ]
Seiffert, Moritz [2 ]
Schaefer, Andreas [1 ,3 ]
机构
[1] Univ Heart & Vasc Ctr Hamburg, Dept Cardiovasc Surg, Hamburg, Germany
[2] Univ Heart & Vasc Ctr Hamburg, Dept Cardiol, Hamburg, Germany
[3] Univ Heart & Vasc Ctr Hamburg, Dept Cardiovasc Surg, Martinistr 52, D-20246 Hamburg, Germany
关键词
aortic annulus; aortic valve stenosis; balloon expandable; transcatheter aortic valve implantation; transcatheter heart valve; IMPACT; CALCIFICATION; IMPLANTATION; REPLACEMENT; OUTCOMES;
D O I
10.1002/ccd.30922
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Objectives Transcatheter aortic valve implantation (TAVI) using balloon-expandable (BE) transcatheter heart valves (THV) in aortic annuli above 29 mm includes particular procedural steps, mainly involving overfilling of the deployment balloon. Data on overfilling strategies in clinical daily practice is scarce. We herein aimed for a retrospective description of utilized overfilling strategies in those patients.Methods Between January 2016 and December 2022, 45 patients (100% male, 76.9 +/- 6.1 years) received TAVI in aortic annuli above 29 mm using a BE THV. Overfilling volumina of the deployment balloon were left to operators' discretion. Clinical and multislice computed tomography data were retrospectively collected. Clinical endpoints were adjudicated in accordance with the updated standardized VARC-3 definitions.Results Profound overfilling (+4/5 mL) was used in patients with a mild calcium burden (<750 mm(3)) even in aortic annuli of 29.0-30.0 mm. Nominal/slight overfilling (+1 mL) was used in aortic annuli up to 32.5 mm but an intermediate to severe calcific burden (>750-3200 mm(3)). Accordingly, a low calcification group (<750 mm(3), n = 17) compared to a significant calcification group (>= 750 mm(3), n = 28), presented with higher overfilling volumina (2.1 +/- 1.4 vs. 0.8 +/- 1.0; p < 0.001), although aortic annulus diameter was not different (29.8 +/- 0.8 vs. 29.9 +/- 0.9 mm; p = 0.7). All-cause 30-day mortality was 0%. Device success was 97.8%. Transvalvular mean pressure gradient at discharge was 9.5 +/- 3.6 mmHg. No case of PVL >mild was documented.Conclusion Extent of overfilling of the deployment balloon largely depends on calcification burden in addition to aortic annulus diameter with significant and profound overfilling particularly in patients with a calcification burden of the aortic valve complex <750 mm(3).
引用
收藏
页码:194 / 201
页数:8
相关论文
共 50 条
[31]   Transcatheter Aortic Valve Replacement With a Balloon-expandable Valve for the Treatment of Noncalcified Bicuspid Aortic Valve Disease [J].
Urena, Marina ;
Doyle, Daniel ;
Dumont, Eric ;
Ribeiro, Henrique Barbosa ;
Bilodeau, Sylvie ;
Rodes-Cabau, Josep .
REVISTA ESPANOLA DE CARDIOLOGIA, 2014, 67 (04) :327-329
[32]   Evaluation of Acquired Thrombocytopenia According to the Balloon-Expandable Versus Self-Expandable Valves in Patients Undergoing Transcatheter Aortic Valve Replacement [J].
Kisacik, Halil ;
Tok, Derya ;
Balci, Kevser Gulcihan ;
Demirkan, Burcu ;
Karakurt, Mustafa ;
Acar, Burak ;
Karabulut, Ozlem ;
Erbay, Ilke ;
Balci, Mustafa Mucahit .
ANGIOLOGY, 2021, 72 (03) :290-294
[33]   Transcatheter aortic valve implantation using balloon-expandable Myval transcatheter heart valve in a patient with bicuspid aortic valve with low-flow, low-gradient severe aortic stenosis [J].
Adhikari, Chandra Mani ;
Bogati, Amrit ;
Timalsena, Birat Krishna ;
Safi, Md. Sajjad ;
Kharel, Sushant ;
Thapa, Pratik ;
Ghimire, Vijay ;
Yadav, Rahul ;
Khan, Barkadin ;
Prajapati, Dipanker .
NEPALESE HEART JOURNAL, 2024, 21 (02) :43-46
[34]   Transcatheter Aortic Valve Implantation in Small and Very Small Aortic Valve Annuli: A Propensity-Matched Analysis Between Self-Expanding Versus Balloon-Expandable Valves [J].
Itach, Tamar ;
Loewenstein, Itamar ;
Zahler, David ;
Finkelstein, Ariel ;
Barbash, Israel ;
Greener, Gabby Elbaz ;
Assa-Vaknin, Hana ;
Kornowski, Ran ;
Turyan, Anna ;
Steinvil, Arie .
CATHETERIZATION AND CARDIOVASCULAR INTERVENTIONS, 2025, 105 (03) :624-632
[35]   Repeat transcatheter aortic valve implantation using a latest generation balloon-expandable device for treatment of failing transcatheter heart valves [J].
Andreas Schaefer ;
Hendrik Treede ;
Moritz Seiffert ;
Florian Deuschl ;
Niklas Schofer ;
Yvonne Schneeberger ;
Stefan Blankenberg ;
Hermann Reichenspurner ;
Ulrich Schaefer ;
Lenard Conradi .
Journal of Cardiothoracic Surgery, 11
[36]   Third-Generation Balloon and Self-Expandable Valves for Aortic Stenosis in Large and Extra-Large Aortic Annuli From the TAVR-LARGE Registry [J].
Armijo, German ;
Tang, Gilbert H. L. ;
Kooistra, Nynke ;
Ferreira-Neto, Alfredo Nunes ;
Toggweiler, Stefan ;
Amat-Santos, Ignacio J. ;
Keller, Lukas S. ;
Urena, Marina ;
Ahmad, Hasan ;
Soto, Jose Tafur ;
Munoz-Garcia, Erika ;
Regueiro, Ander ;
Leenders, Geert E. ;
Tirado-Conte, Gabriela ;
Sengupta, Aditya ;
McInerney, Angela ;
Couture, Thomas ;
Herreros, Oscar Cuevas ;
Rodriguez-Gabella, Tania ;
Kini, Annapoorna ;
Ahmed, Mohammed ;
Zaid, Syed ;
Gonzalo, Nieves ;
Nunez-Gil, Ivan J. ;
Munoz-Garcia, Antonio J. ;
Jimenez-Quevedo, Pilar ;
Fernandez-Ortiz, Antonio ;
Himbert, Dominique ;
Nietlispach, Fabian ;
Stella, Pieter ;
Dangas, George D. ;
Escaned, Javier ;
Macaya, Carlos ;
Rodes-Cabau, Josep ;
Nombela-Franco, Luis .
CIRCULATION-CARDIOVASCULAR INTERVENTIONS, 2020, 13 (08) :E009047
[37]   Clinical Comparison of a Novel Balloon-Expandable Versus a Self-Expanding Transcatheter Heart Valve for the Treatment of Patients with Severe Aortic Valve Stenosis: The EVAL Registry [J].
Barki, Monica ;
Ielasi, Alfonso ;
Buono, Andrea ;
Maliandi, Gabriele ;
Pellicano, Mariano ;
Bande, Marta ;
Casilli, Francesco ;
Messina, Francesca ;
Uccello, Giuseppe ;
Briguglia, Daniele ;
Medda, Massimo ;
Tespili, Maurizio ;
Donatelli, Francesco .
JOURNAL OF CLINICAL MEDICINE, 2022, 11 (04)
[38]   Efficacy of larger valve sizing with underfilling in balloon-expandable transcatheter aortic valve replacement [J].
Kawaguchi, Tomohiro ;
Miyoshi, Toru ;
Hayashi, Masaomi ;
Ishizu, Kenichi ;
Ugawa, Satoko ;
Nosaka, Kazumasa ;
Isotani, Akihiro ;
Doi, Masayuki ;
Shirai, Shinichi ;
Ando, Kenji .
CATHETERIZATION AND CARDIOVASCULAR INTERVENTIONS, 2022, 99 (07) :2082-2091
[39]   Safety and efficacy of minimalist transcatheter aortic valve implantation using a new-generation balloon-expandable transcatheter heart valve in bicuspid and tricuspid aortic valves [J].
Jonathan M. Michel ;
Antonio H. Frangieh ;
Daniele Giacoppo ;
Hector A. Alvarez-Covarrubias ;
Costanza Pellegrini ;
Tobias Rheude ;
Oliver Deutsch ;
N. Patrick Mayr ;
P. Moritz Rumpf ;
Barbara E. Stähli ;
Adnan Kastrati ;
Heribert Schunkert ;
Erion Xhepa ;
Michael Joner ;
A. Markus Kasel .
Clinical Research in Cardiology, 2021, 110 :1993-2006
[40]   Prosthesis-patient mismatch after transcatheter implantation of contemporary balloon-expandable and self-expandable valves in small aortic annuli [J].
Leone, Pier Pasquale ;
Regazzoli, Damiano ;
Pagnesi, Matteo ;
Costa, Giuliano ;
Teles, Rui ;
Adamo, Marianna ;
Taramasso, Maurizio ;
De Marco, Federico ;
Mangieri, Antonio ;
Kargoli, Faraj ;
Ohno, Yohei ;
Saia, Francesco ;
Ielasi, Alfonso ;
Ribichini, Flavio ;
Maffeo, Diego ;
Kim, Won-Keun ;
Maisano, Francesco ;
Van Mieghem, Nicolas M. ;
Colombo, Antonio ;
Reimers, Bernhard ;
Latib, Azeem .
CATHETERIZATION AND CARDIOVASCULAR INTERVENTIONS, 2023, 102 (05) :931-943