Balloon-expandable transcatheter heart valves for treatment of aortic valve stenosis in patients with large aortic annuli: Evaluation of deployment balloon overfilling strategies

被引:0
作者
Schneeberger, Yvonne [1 ]
Sarwari, Harun [1 ]
Koell, Benedikt [2 ]
Demal, Till J. [1 ]
Bhadra, Oliver D. [1 ]
von der Heide, Ina [2 ]
Hannen, Laura [2 ]
Grundmann, David [2 ]
Voigtlaender, Lisa [2 ]
Waldschmidt, Lara [2 ]
Schirmer, Johannes [1 ]
Pecha, Simon [1 ]
Schofer, Niklas [2 ]
Soerensen, Nils [2 ]
Blankenberg, Stefan [2 ]
Reichenspurner, Hermann [1 ]
Conradi, Lenard [1 ]
Seiffert, Moritz [2 ]
Schaefer, Andreas [1 ,3 ]
机构
[1] Univ Heart & Vasc Ctr Hamburg, Dept Cardiovasc Surg, Hamburg, Germany
[2] Univ Heart & Vasc Ctr Hamburg, Dept Cardiol, Hamburg, Germany
[3] Univ Heart & Vasc Ctr Hamburg, Dept Cardiovasc Surg, Martinistr 52, D-20246 Hamburg, Germany
关键词
aortic annulus; aortic valve stenosis; balloon expandable; transcatheter aortic valve implantation; transcatheter heart valve; IMPACT; CALCIFICATION; IMPLANTATION; REPLACEMENT; OUTCOMES;
D O I
10.1002/ccd.30922
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Objectives Transcatheter aortic valve implantation (TAVI) using balloon-expandable (BE) transcatheter heart valves (THV) in aortic annuli above 29 mm includes particular procedural steps, mainly involving overfilling of the deployment balloon. Data on overfilling strategies in clinical daily practice is scarce. We herein aimed for a retrospective description of utilized overfilling strategies in those patients.Methods Between January 2016 and December 2022, 45 patients (100% male, 76.9 +/- 6.1 years) received TAVI in aortic annuli above 29 mm using a BE THV. Overfilling volumina of the deployment balloon were left to operators' discretion. Clinical and multislice computed tomography data were retrospectively collected. Clinical endpoints were adjudicated in accordance with the updated standardized VARC-3 definitions.Results Profound overfilling (+4/5 mL) was used in patients with a mild calcium burden (<750 mm(3)) even in aortic annuli of 29.0-30.0 mm. Nominal/slight overfilling (+1 mL) was used in aortic annuli up to 32.5 mm but an intermediate to severe calcific burden (>750-3200 mm(3)). Accordingly, a low calcification group (<750 mm(3), n = 17) compared to a significant calcification group (>= 750 mm(3), n = 28), presented with higher overfilling volumina (2.1 +/- 1.4 vs. 0.8 +/- 1.0; p < 0.001), although aortic annulus diameter was not different (29.8 +/- 0.8 vs. 29.9 +/- 0.9 mm; p = 0.7). All-cause 30-day mortality was 0%. Device success was 97.8%. Transvalvular mean pressure gradient at discharge was 9.5 +/- 3.6 mmHg. No case of PVL >mild was documented.Conclusion Extent of overfilling of the deployment balloon largely depends on calcification burden in addition to aortic annulus diameter with significant and profound overfilling particularly in patients with a calcification burden of the aortic valve complex <750 mm(3).
引用
收藏
页码:194 / 201
页数:8
相关论文
共 50 条
[21]   Undersizing but overfilling eliminates the gray zones of sizing for transcatheter aortic valve replacement with the balloon-expandable bioprosthesis [J].
Patsalis, Polykarpos C. ;
Kloppe, Axel ;
Plicht, Bjoern ;
Schoene, Dominik ;
Schiedat, Fabian ;
Aweimer, Assem ;
Kara, Kaffer ;
Haldenwang, Peter Lukas ;
Strauch, Justus Thomas ;
Buck, Thomas ;
Muegge, Andreas .
IJC HEART & VASCULATURE, 2020, 30
[22]   New 29-mm Balloon-Expandable Prosthesis for Transcatheter Aortic Valve Implantation in Large Annuli [J].
Unbehaun, Axel ;
Pasic, Miralem ;
Drews, Thorsten ;
Buz, Semih ;
Dreysse, Stephan ;
Kukucka, Marian ;
Mladenow, Alexander ;
Ivanitskaja-Kuehn, Ekaterina ;
Hetzer, Roland .
ANNALS OF THORACIC SURGERY, 2013, 95 (06) :1982-1990
[23]   Early hypo-attenuated leaflet thickening in balloon-expandable transcatheter aortic heart valves [J].
Pache, Gregor ;
Schoechlin, Simon ;
Blanke, Philipp ;
Dorfs, Stephan ;
Jander, Nikolaus ;
Arepalli, Chesnal D. ;
Gick, Michael ;
Buettner, Heinz-Joachim ;
Leipsic, Jonathon ;
Langer, Mathias ;
Neumann, Franz-Josef ;
Ruile, Philipp .
EUROPEAN HEART JOURNAL, 2016, 37 (28) :2263-2271
[24]   Prospective Study of TMVR Using Balloon-Expandable Aortic Transcatheter Valves in MAC [J].
Guerrero, Mayra ;
Wang, Dee Dee ;
Eleid, Mackram F. ;
Pursnani, Amit ;
Salinger, Michael ;
Russell, Hyde M. ;
Kodali, Susheel K. ;
George, Isaac ;
Bapat, Vinayak N. ;
Dangas, George D. ;
Tang, Gilbert H. L. ;
Inglesis, Ignacio ;
Meduri, Christopher U. ;
Palacios, Igor ;
Reisman, Mark ;
Whisenant, Brian K. ;
Jermihov, Anastasia ;
Kaptzan, Tatiana ;
Lewis, Bradley R. ;
Tommaso, Carl ;
Krause, Philip ;
Thaden, Jeremy ;
Oh, Jae K. ;
Douglas, Pamela S. ;
Hahn, Rebecca T. ;
Leon, Martin B. ;
Rihal, Charanjit S. ;
Feldman, Ted ;
O'Neill, William W. .
JACC-CARDIOVASCULAR INTERVENTIONS, 2021, 14 (08) :830-845
[25]   Applicability of next generation balloon-expandable transcatheter heart valves in aortic annuli exceeding formally approved dimensions [J].
Andreas Schaefer ;
Matthias Linder ;
Hendrik Treede ;
Florian Deuschl ;
Niklas Schofer ;
Moritz Seiffert ;
Yvonne Schneeberger ;
Stefan Blankenberg ;
Hermann Reichenspurner ;
Ulrich Schaefer ;
Lenard Conradi .
Clinical Research in Cardiology, 2016, 105 :585-591
[26]   Stent and leaflet stresses across generations of balloon-expandable transcatheter aortic valves [J].
Xuan, Yue ;
Dvir, Danny ;
Wang, Zhongjie ;
Ye, Jian ;
Guccione, Julius M. ;
Ge, Liang ;
Tseng, Elaine E. .
INTERACTIVE CARDIOVASCULAR AND THORACIC SURGERY, 2020, 30 (06) :879-886
[27]   Use of Balloon Aortic Valvuloplasty to Size the Aortic Annulus Before Implantation of a Balloon-Expandable Transcatheter Heart Valve [J].
Babaliaros, Vasilis C. ;
Junagadhwalla, Zahid ;
Lerakis, Stamatios ;
Thourani, Vinod ;
Liff, David ;
Chen, Edward ;
Vassiliades, Thomas ;
Chappell, Clay ;
Gross, Nathan ;
Patel, Ateet ;
Howell, Sharon ;
Green, Jacob T. ;
Veledar, Emir ;
Guyton, Robert ;
Block, Peter C. .
JACC-CARDIOVASCULAR INTERVENTIONS, 2010, 3 (01) :114-118
[28]   New-Generation Transcatheter Aortic Valves in Patients With Small Aortic Annuli - Comparison of Balloon- and Self-Expandable Valves in Asian Patients - [J].
Okuyama, Kazuaki ;
Izumo, Masaki ;
Ochiai, Tomoki ;
Kuwata, Shingo ;
Kaihara, Toshiki ;
Koga, Masashi ;
Kamijima, Ryo ;
Ishibashi, Yuki ;
Tanabe, Yasuhiro ;
Higuma, Takumi ;
Makkar, Raj ;
Miyairi, Takeshi ;
Akashi, Yoshihiro J. .
CIRCULATION JOURNAL, 2020, 84 (11) :2015-2022
[29]   Valve Performance Between Latest-Generation Balloon-Expandable and Self-Expandable Transcatheter Heart Valves in a Small Aortic Annulus [J].
Hioki, Hirofumi ;
Yamamoto, Masanori ;
Shirai, Shinichi ;
Ohno, Yohei ;
Yashima, Fumiaki ;
Naganuma, Toru ;
Yamawaki, Masahiro ;
Watanabe, Yusuke ;
Yamanaka, Futoshi ;
Mizutani, Kazuki ;
Ryuzaki, Toshinobu ;
Noguchi, Masahiko ;
Izumo, Masaki ;
Takagi, Kensuke ;
Asami, Masahiko ;
Ueno, Hiroshi ;
Nishina, Hidetaka ;
Otsuka, Toshiaki ;
Suzuyama, Hiroto ;
Yamasaki, Kazumasa ;
Nishioka, Kenji ;
Hachinohe, Daisuke ;
Fuku, Yasushi ;
Hayashida, Kentaro .
JACC-CARDIOVASCULAR INTERVENTIONS, 2024, 17 (22) :2612-2622
[30]   Balloon-Expandable vs Self-Expanding Valves for Transcatheter Treatment of Sievers Type 1 Bicuspid Aortic Stenosis [J].
Buono, Andrea ;
Zito, Andrea ;
Kim, Won-Keun ;
Fabris, Tommaso ;
De Biase, Chiara ;
Bellamoli, Michele ;
Montarello, Nicholas ;
Costa, Giuliano ;
Alfadhel, Mesfer ;
Koren, Ofir ;
Fezzi, Simone ;
Bellini, Barbara ;
Massussi, Mauro ;
Scotti, Andrea ;
Bai, Lin ;
Costa, Giulia ;
Mazzapicchi, Alessandro ;
Giacomin, Enrico ;
Gorla, Riccardo ;
Hug, Karsten ;
Briguori, Carlo ;
Bettari, Luca ;
Messina, Antonio ;
Boiago, Mauro ;
Villa, Emmanuel ;
Renker, Matthias ;
Gomez, Mario Garcia ;
Fraccaro, Chiara ;
Rosa, Maria Luisa De ;
Patel, Vivek ;
Trani, Carlo ;
De Carlo, Marco ;
Laterra, Giulia ;
Latini, Alessia ;
Pellegrini, Dario ;
Ielasi, Alfonso ;
Orbach, Ady ;
Landes, Uri ;
Rheude, Tobias ;
Testa, Luca ;
Santos, Ignacio Amat ;
Mangieri, Antonio ;
Saia, Francesco ;
Favero, Luca ;
Chen, Mao ;
Adamo, Marianna ;
Latib, Azeem ;
Petronio, Anna Sonia ;
Montorfano, Matteo ;
Makkar, Raj R. .
JACC-CARDIOVASCULAR INTERVENTIONS, 2024, 17 (22) :2596-2608