Balloon-expandable transcatheter heart valves for treatment of aortic valve stenosis in patients with large aortic annuli: Evaluation of deployment balloon overfilling strategies

被引:0
|
作者
Schneeberger, Yvonne [1 ]
Sarwari, Harun [1 ]
Koell, Benedikt [2 ]
Demal, Till J. [1 ]
Bhadra, Oliver D. [1 ]
von der Heide, Ina [2 ]
Hannen, Laura [2 ]
Grundmann, David [2 ]
Voigtlaender, Lisa [2 ]
Waldschmidt, Lara [2 ]
Schirmer, Johannes [1 ]
Pecha, Simon [1 ]
Schofer, Niklas [2 ]
Soerensen, Nils [2 ]
Blankenberg, Stefan [2 ]
Reichenspurner, Hermann [1 ]
Conradi, Lenard [1 ]
Seiffert, Moritz [2 ]
Schaefer, Andreas [1 ,3 ]
机构
[1] Univ Heart & Vasc Ctr Hamburg, Dept Cardiovasc Surg, Hamburg, Germany
[2] Univ Heart & Vasc Ctr Hamburg, Dept Cardiol, Hamburg, Germany
[3] Univ Heart & Vasc Ctr Hamburg, Dept Cardiovasc Surg, Martinistr 52, D-20246 Hamburg, Germany
关键词
aortic annulus; aortic valve stenosis; balloon expandable; transcatheter aortic valve implantation; transcatheter heart valve; IMPACT; CALCIFICATION; IMPLANTATION; REPLACEMENT; OUTCOMES;
D O I
10.1002/ccd.30922
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Objectives Transcatheter aortic valve implantation (TAVI) using balloon-expandable (BE) transcatheter heart valves (THV) in aortic annuli above 29 mm includes particular procedural steps, mainly involving overfilling of the deployment balloon. Data on overfilling strategies in clinical daily practice is scarce. We herein aimed for a retrospective description of utilized overfilling strategies in those patients.Methods Between January 2016 and December 2022, 45 patients (100% male, 76.9 +/- 6.1 years) received TAVI in aortic annuli above 29 mm using a BE THV. Overfilling volumina of the deployment balloon were left to operators' discretion. Clinical and multislice computed tomography data were retrospectively collected. Clinical endpoints were adjudicated in accordance with the updated standardized VARC-3 definitions.Results Profound overfilling (+4/5 mL) was used in patients with a mild calcium burden (<750 mm(3)) even in aortic annuli of 29.0-30.0 mm. Nominal/slight overfilling (+1 mL) was used in aortic annuli up to 32.5 mm but an intermediate to severe calcific burden (>750-3200 mm(3)). Accordingly, a low calcification group (<750 mm(3), n = 17) compared to a significant calcification group (>= 750 mm(3), n = 28), presented with higher overfilling volumina (2.1 +/- 1.4 vs. 0.8 +/- 1.0; p < 0.001), although aortic annulus diameter was not different (29.8 +/- 0.8 vs. 29.9 +/- 0.9 mm; p = 0.7). All-cause 30-day mortality was 0%. Device success was 97.8%. Transvalvular mean pressure gradient at discharge was 9.5 +/- 3.6 mmHg. No case of PVL >mild was documented.Conclusion Extent of overfilling of the deployment balloon largely depends on calcification burden in addition to aortic annulus diameter with significant and profound overfilling particularly in patients with a calcification burden of the aortic valve complex <750 mm(3).
引用
收藏
页码:194 / 201
页数:8
相关论文
共 50 条
  • [1] Transcatheter Valve-In-Valve Implantation for Failed Balloon-Expandable Transcatheter Aortic Valves
    Toggweiler, Stefan
    Wood, David A.
    Rodes-Cabau, Josep
    Kapadia, Samir
    Willson, Alexander B.
    Ye, Jian
    Cheung, Anson
    Leipsic, Jonathon
    Binder, Ronald K.
    Gurvitch, Ronen
    Freeman, Melanie
    Thompson, Christopher R.
    Svensson, Lars G.
    Dumont, Eric
    Tuzcu, E. Murat
    Webb, John G.
    JACC-CARDIOVASCULAR INTERVENTIONS, 2012, 5 (05) : 571 - 577
  • [2] Applicability of next generation balloon-expandable transcatheter heart valves in aortic annuli exceeding formally approved dimensions
    Schaefer, Andreas
    Linder, Matthias
    Treede, Hendrik
    Deuschl, Florian
    Schofer, Niklas
    Seiffert, Moritz
    Schneeberger, Yvonne
    Blankenberg, Stefan
    Reichenspurner, Hermann
    Schaefer, Ulrich
    Conradi, Lenard
    CLINICAL RESEARCH IN CARDIOLOGY, 2016, 105 (07) : 585 - 591
  • [3] Combination Use of Inoue-Balloon and Self-Expandable Transcatheter Valves in Managing Aortic Stenosis Not Amenable to Balloon-Expandable Valves
    Saji, Mike
    Highchi, Ryosuke
    Iguchi, Nobuo
    Takamisawa, Itaru
    Shimizu, Jun
    Shimokawa, Tomoki
    Nanasato, Mamoru
    Takayama, Morimasa
    Isobe, Mitsuaki
    INTERNATIONAL HEART JOURNAL, 2022, 63 (05) : 843 - 851
  • [4] Repositionable Versus Balloon-Expandable Devices for Transcatheter Aortic Valve Implantation in Patients With Aortic Stenosis
    Pilgrim, Thomas
    Stortecky, Stefan
    Nietlispach, Fabian
    Heg, Dik
    Tueller, David
    Toggweiler, Stefan
    Ferrari, Enrico
    Noble, Stephane
    Maisano, Francesco
    Jeger, Raban
    Roffi, Marco
    Gruenenfelder, Juerg
    Huber, Christoph
    Wenaweser, Peter
    Windecker, Stephan
    JOURNAL OF THE AMERICAN HEART ASSOCIATION, 2016, 5 (11):
  • [5] Predictors of conduction disturbances after transcatheter aortic valve implantation with balloon-expandable valve for bicuspid aortic valve stenosis
    Miyashita, Hirokazu
    Moriyama, Noriaki
    Yamanaka, Futoshi
    Saito, Shigeru
    Lehtola, Heidi
    Piuhola, Jarkko
    Niemela, Matti
    Laine, Mika
    JOURNAL OF CARDIOVASCULAR ELECTROPHYSIOLOGY, 2022, 33 (07) : 1576 - 1586
  • [6] Comparison of balloon-expandable valves versus self-expandable valves in high-risk patients undergoing transcatheter aortic valve replacement for severe aortic stenosis
    Chang, Hsiao-Huang
    Chen, I-Ming
    Chen, Po-Lin
    Hsu, Tsui-Lieh
    Lin, Su-Man
    Chen, Ying-Hwa
    JOURNAL OF THE CHINESE MEDICAL ASSOCIATION, 2015, 78 (06) : 331 - 338
  • [7] Repeat transcatheter aortic valve implantation using a latest generation balloon-expandable device for treatment of failing transcatheter heart valves
    Schaefer, Andreas
    Treede, Hendrik
    Seiffert, Moritz
    Deuschl, Florian
    Schofer, Niklas
    Schneeberger, Yvonne
    Blankenberg, Stefan
    Reichenspurner, Hermann
    Schaefer, Ulrich
    Conradi, Lenard
    JOURNAL OF CARDIOTHORACIC SURGERY, 2016, 11
  • [8] Transcatheter Aortic Valve Replacement With the SAPIEN 3 A New Balloon-Expandable Transcatheter Heart Valve
    Binder, Ronald K.
    Rodes-Cabau, Josep
    Wood, David A.
    Mok, Michael
    Leipsic, Jonathon
    De Larochelliere, Robert
    Toggweiler, Stefan
    Dumont, Eric
    Freeman, Melanie
    Willson, Alexander B.
    Webb, John G.
    JACC-CARDIOVASCULAR INTERVENTIONS, 2013, 6 (03) : 293 - 300
  • [9] Balloon-Expandable Transcatheter Aortic Valve Replacement in Patients with Severe Aortic Stenosis and Mild Aortic Valve Calcification
    Abramowitz, Yigal
    Jilaihawi, Hasan
    Chakravarty, Tarun
    Kashif, Mohammad
    Kazuno, Yoshio
    Maeno, Yoshio
    Takahashi, Nobuyuki
    Kawamori, Hiroyuki
    Sharma, Rahul P.
    Cox, Justin
    Cheng, Wen
    Makkar, Raj
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2015, 66 (15) : B257 - B257
  • [10] Safety and efficacy of minimalist transcatheter aortic valve implantation using a new-generation balloon-expandable transcatheter heart valve in bicuspid and tricuspid aortic valves
    Michel, Jonathan M.
    Frangieh, Antonio H.
    Giacoppo, Daniele
    Alvarez-Covarrubias, Hector A.
    Pellegrini, Costanza
    Rheude, Tobias
    Deutsch, Oliver
    Mayr, N. Patrick
    Rumpf, P. Moritz
    Stahli, Barbara E.
    Kastrati, Adnan
    Schunkert, Heribert
    Xhepa, Erion
    Joner, Michael
    Kasel, A. Markus
    CLINICAL RESEARCH IN CARDIOLOGY, 2021, 110 (12) : 1993 - 2006