Modification of the pulmonary vein antrum is associated with recurrence after durable pulmonary vein isolation for paroxysmal atrial fibrillation

被引:0
作者
Kujiraoka, Hirofumi [1 ]
Hojo, Rintaro [1 ]
Arai, Tomoyuki [1 ]
Takahashi, Masao [1 ]
Fukamizu, Seiji [1 ]
Sasano, Tetsuo [2 ]
机构
[1] Tokyo Metropolitan Hiroo Gen Hosp, Dept Cardiol, 2-34-10 Ebisu,Shibuya Ku, Tokyo 1500013, Japan
[2] Tokyo Med & Dent Univ, Dept Cardiovasc Med, Tokyo, Japan
关键词
Pulmonary vein isolation; Cryoballoon; Atrial fibrillation; Atrial tachycardia; Recurrence; DURABILITY;
D O I
10.1007/s10840-023-01668-9
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background: Although previous studies have shown the isolated areas after pulmonary vein isolation (PVI) using cryoballoons (CB) (CB-PVI), no studies have investigated the association between the isolated area and recurrence of atrial fibrillation (AF) and atrial tachycardia (AT). This single-center observational study investigated the association between the ablated area and recurrence rate after durable CB-PVI for paroxysmal AF.Methods: This study included 76 patients with paroxysmal AF who underwent CB-PVI and established durable PVI with a second procedure, regardless of AF/AT recurrence, 6 months after the first procedure. To compare the ablated zones, we quantified the left- and right-sided PV antral isolation areas and non-ablated posterior wall (PW) area. We examined non-ablated areas of the PW and AF/AT recurrence in the chronic phase.Results: In total, 16 of the 76 patients had AF/AT recurrence. The mean follow-up duration was 34 months. The non-ablated PW area (14.0 +/- 4.6 cm(2) vs. 11.5 +/- 3.7 cm(2); p = 0.0213) and the ratio of the non-ablated PW area to the whole PW area (NAPW) (52.9 +/- 9.1% vs. 44.8 +/- 9.8%; p = 0.003) were significantly higher in the AF/AT recurrence group than in the AF/AT non-recurrence group. NAPW > 50% was an independent predictor of AF/AT recurrence.Conclusion: The NAPW after durable CB-PVI is associated with AF/AT recurrence. PW isolation or additional applications on the PV antrum with cryoballoon may be considered in addition to PVI in paroxysmal AF, especially in patients with dilated left atria.
引用
收藏
页码:1109 / 1116
页数:8
相关论文
共 16 条
[1]   High-Resolution Mapping of Scar-Related Atrial Arrhythmias Using Smaller Electrodes With Closer Interelectrode Spacing [J].
Anter, Elad ;
Tschabrunn, Cory M. ;
Josephson, Mark E. .
CIRCULATION-ARRHYTHMIA AND ELECTROPHYSIOLOGY, 2015, 8 (03) :537-545
[2]   Pulmonary Vein Isolation With and Without Posterior Wall Isolation in Paroxysmal Atrial Fibrillation [J].
Aryana, Arash ;
Thiemann, Anna M. ;
Pujara, Deep K. ;
Cossette, Laura L. ;
Allen, Shelley L. ;
Bowers, Mark R. ;
Gandhavadi, Maheer ;
Heath, Russell ;
Trivedi, Amar D. ;
O'Neill, Padraig Gearoid ;
Ellis, Ethan R. ;
d'Avila, Andre .
JACC-CLINICAL ELECTROPHYSIOLOGY, 2023, 9 (05) :628-637
[3]   The durability of pulmonary vein isolation using the visually guided laser balloon catheter: Multicenter results of pulmonary vein remapping studies [J].
Dukkipati, Srinivas R. ;
Neuzil, Petr ;
Kautzner, Josef ;
Petru, Jan ;
Wichterle, Dan ;
Skoda, Jan ;
Cihak, Robert ;
Peichl, Petr ;
Dello Russo, Antonio ;
Pelargonio, Gemma ;
Tondo, Claudio ;
Natale, Andrea ;
Reddy, Vivek Y. .
HEART RHYTHM, 2012, 9 (06) :919-925
[4]   Comparison of touch-up ablation rate and pulmonary vein isolation durability between hot balloon and cryoballoon [J].
Hojo, Rintaro ;
Fukamizu, Seiji ;
Tokioka, Sayuri ;
Inagaki, Dai ;
Miyazawa, Satoshi ;
Kawamura, Iwanari ;
Kitamura, Takeshi ;
Sakurada, Harumizu ;
Hiraoka, Masayasu .
JOURNAL OF CARDIOVASCULAR ELECTROPHYSIOLOGY, 2020, 31 (06) :1298-1306
[5]  
Hojo Rintaro, 2017, JACC Clin Electrophysiol, V3, P547, DOI [10.1016/j.jacep.2016.12.008, 10.1016/j.jacep.2016.12.008]
[6]   Outcomes of posterior wall isolation with pulmonary vein isolation for paroxysmal atrial fibrillation [J].
Jankelson, Lior ;
Garber, Leonid ;
Shulman, Eric ;
Bar Cohen, Roi ;
Peterson, Connor ;
Wadhwani, Lalit ;
Nadeau-Routhier, Charles ;
Xia, Yuhe ;
Barbhaiya, Chirag ;
Holmes, Douglas ;
Knotts, Robert ;
Bernstein, Scott ;
Kushnir, Alexander ;
Spinelli, Michael ;
Park, David ;
Aizer, Anthony ;
Chinitz, Larry .
JOURNAL OF CARDIOVASCULAR ELECTROPHYSIOLOGY, 2022, 33 (02) :209-217
[7]   EFFICAS II: optimization of catheter contact force improves outcome of pulmonary vein isolation for paroxysmal atrial fibrillation [J].
Kautzner, Josef ;
Neuzil, Petr ;
Lambert, Hendrik ;
Peichl, Petr ;
Petru, Jan ;
Cihak, Robert ;
Skoda, Jan ;
Wichterle, Dan ;
Wissner, Erik ;
Yulzari, Aude ;
Kuck, Karl-Heinz .
EUROPACE, 2015, 17 (08) :1229-1235
[8]   Quantitative Analysis of Isolation Area and Rhythm Outcome in Patients With Paroxysmal Atrial Fibrillation After Circumferential Pulmonary Vein Antrum Isolation Using the Pace-and-Ablate Technique [J].
Kiuchi, Kunihiko ;
Kircher, Simon ;
Watanabe, Norikazu ;
Gaspar, Thomas ;
Rolf, Sascha ;
Arya, Arash ;
Piorkowski, Christopher ;
Hindricks, Gerhard ;
Sommer, Philipp .
CIRCULATION-ARRHYTHMIA AND ELECTROPHYSIOLOGY, 2012, 5 (04) :667-675
[9]   Electro-anatomic mapping systems in arrhythmias [J].
Knackstedt, Christian ;
Schauerte, Patrick ;
Kirchhof, Paulus .
EUROPACE, 2008, 10 :28-34
[10]   Quantitative Analysis of the Isolation Area During the Chronic Phase After a 28-mm Second-Generation Cryoballoon Ablation Demarcated by High-Resolution Electroanatomic Mapping [J].
Miyazaki, Shinsuke ;
Taniguchi, Hiroshi ;
Hachiya, Hitoshi ;
Nakamura, Hiroaki ;
Takagi, Takamitsu ;
Iwasawa, Jin ;
Hirao, Kenzo ;
Iesaka, Yoshito .
CIRCULATION-ARRHYTHMIA AND ELECTROPHYSIOLOGY, 2016, 9 (05)