3D simulation of percutaneous sustentaculum tali screw insertion in calcaneal fractures

被引:0
|
作者
Li, Xian [1 ,2 ]
Wang, Xiao-ke [1 ]
Yu, Lian-kui [2 ]
Zhang, Chao [2 ]
Zhao, Ming-ming [2 ]
Yan, Jun [2 ]
Han, Li-ren [2 ]
机构
[1] Weifang Med Univ, Sch Clin Med, Weifang, Peoples R China
[2] Liaocheng Peoples Hosp, Dept Orthopaed Surg, Liaocheng, Peoples R China
关键词
Calcaneal fracture; Percutaneous screw fixation; Sustentaculum tali; Digital measurement; SANDERS TYPE-II; PLACEMENT; FIXATION;
D O I
10.1186/s12891-023-06748-5
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Background In calcaneal fractures, the percutaneous screw fixation (PSF) is currently considered to be the better choice, but it is difficult to accurately place the screw into the sustentaculum tali (ST) during the operation. In this study, the ideal entry point, angle, diameter and length of the screw were calculated by simulating the operation process. Methods We retrospectively collected the calcaneus computed tomography (CT) scans of 180 adults, DICOM-formatted CT-scan images of each patient were imported into Mimics software to establish calcaneus model. Virtual screws were placed on the lateral of the posterior talar articular surface (PTAS), the lateral edge of the anterior process of calcaneus (APC), and the calcaneal tuberosity, respectively, the trajectory and size of the screws were calculated. Results The mean maximum diameter of the PTAS screw was 42.20 +/- 3.71 mm. The vertical distance between the midpoint of the APC optimal screw trajectory and the lowest point of the tarsal sinus was 10.67 +/- 1.84 mm, and the distance between the midpoint of the APC optimal screw trajectory and the calcaneocuboid joint was 5 mm similar to 19.81 +/- 2.08 mm. The mean maximum lengths of APC screws was 44.69 +/- 4.81 mm, and the Angle between the screw and the coronal plane of the calcaneus from proximal to distal was 4.72 degrees +/- 2.15 degrees to 20.52 degrees +/- 3.77 degrees. The optimal point of the maximum diameter of the calcaneal tuberosity screw was located at the lateral border of the achilles tendon endpoint. The mean maximum diameters of calcaneal tuberosity screws was 4.46 +/- 0.85 mm, the mean maximum lengths of screws was 65.31 +/- 4.76 mm. We found gender- dependent differences for the mean maximum diameter and the maximum length of the three screws. Conclusions The study provides effective positioning for percutaneous screw fixation of calcaneal fractures. For safer and more efficient screw placement, we suggest individualised preoperative 3D reconstruction simulations. Further biomechanical studies are needed to verify the function of the screw.
引用
收藏
页数:7
相关论文
共 50 条
  • [31] Fracture reduction and screw position after 3D-navigated and conventional fluoroscopy-assisted percutaneous management of acetabular fractures: a retrospective comparative study
    Swartman, B.
    Pelzer, J.
    Beisemann, N.
    Schnetzke, M.
    Keil, H.
    Vetter, S. Y.
    Gruetzner, P. A.
    Franke, Jochen
    ARCHIVES OF ORTHOPAEDIC AND TRAUMA SURGERY, 2021, 141 (04) : 593 - 602
  • [32] Percutaneous fixation of intraarticular joint-depression calcaneal fractures with different screw configurations - a biomechanical human cadaveric analysis
    Ivanov, Stoyan
    Stefanov, Aleksandar
    Zderic, Ivan
    Rodemund, Christian
    Schepers, Tim
    Gehweiler, Dominic
    Dauwe, Jan
    Pastor, Torsten
    Makelov, Biser
    Raykov, Dimitur
    Richards, Geoff
    Gueorguiev, Boyko
    EUROPEAN JOURNAL OF TRAUMA AND EMERGENCY SURGERY, 2022, 48 (04) : 3305 - 3315
  • [33] Multimedia 3D clinical planning system for simulation of internal fixation surgery for calcaneal collapse
    Shuh-Ping Sun
    Yi-Jiun Chou
    Yi-Hsin Chiu
    Multimedia Tools and Applications, 2011, 52 : 5 - 18
  • [34] 3D ultrasound navigation system for screw insertion in posterior spine surgery: a phantom study
    Chan, Andrew
    Parent, Eric
    Mahood, Jim
    Lou, Edmond
    INTERNATIONAL JOURNAL OF COMPUTER ASSISTED RADIOLOGY AND SURGERY, 2022, 17 (02) : 271 - 281
  • [35] A guideline for screw fixation of coracoid process base fracture by 3D simulation
    Sun, Zhongye
    Li, Hao
    Wang, Bei
    Yan, Jun
    Han, Liren
    Han, Shizhang
    Yang, Xiaofei
    Zhao, Bei
    JOURNAL OF ORTHOPAEDIC SURGERY AND RESEARCH, 2021, 16 (01)
  • [36] A guideline for screw fixation of coracoid process base fracture by 3D simulation
    Zhongye Sun
    Hao Li
    Bei Wang
    Jun Yan
    Liren Han
    Shizhang Han
    Xiaofei Yang
    Bei Zhao
    Journal of Orthopaedic Surgery and Research, 16
  • [37] Utility of a custom screw insertion guide and a full-scale, color-coded 3D plaster model for guiding safe surgical exposure and screw insertion during spine revision surgery
    Otsuki, Bungo
    Takemoto, Mitsuru
    Fujibayashi, Shunsuke
    Kimura, Hiroaki
    Masamoto, Kazutaka
    Matsuda, Shuichi
    JOURNAL OF NEUROSURGERY-SPINE, 2016, 25 (01) : 94 - 102
  • [38] Multimedia 3D clinical planning system for simulation of internal fixation surgery for calcaneal collapse
    Sun, Shuh-Ping
    Chou, Yi-Jiun
    Chiu, Yi-Hsin
    MULTIMEDIA TOOLS AND APPLICATIONS, 2011, 52 (01) : 5 - 18
  • [39] CT of calcaneal fractures: 3-D-reformations with electronic disarticulation
    Freund, M
    Hohendorff, B
    Zenker, W
    Hutzelmann, A
    Heller, M
    FORTSCHRITTE AUF DEM GEBIETE DER RONTGENSTRAHLEN UND DER NEUEN BILDGEBENDEN VERFAHREN, 1996, 164 (03): : 189 - 195
  • [40] Simulation with 3D Neuronavigation for Learning Cortical Bone Trajectory Screw Placement
    Delgado-Fernandez, Juan
    Frade-Porto, Natalia
    Blasco, Guillermo
    Gonzalez-Tarno, Patricia
    Gil-Simoes, Ricardo
    Pulido, Paloma
    Sola, R. G.
    JOURNAL OF NEUROLOGICAL SURGERY PART A-CENTRAL EUROPEAN NEUROSURGERY, 2021, 82 (03) : 262 - 269