3D simulation of percutaneous sustentaculum tali screw insertion in calcaneal fractures

被引:0
|
作者
Li, Xian [1 ,2 ]
Wang, Xiao-ke [1 ]
Yu, Lian-kui [2 ]
Zhang, Chao [2 ]
Zhao, Ming-ming [2 ]
Yan, Jun [2 ]
Han, Li-ren [2 ]
机构
[1] Weifang Med Univ, Sch Clin Med, Weifang, Peoples R China
[2] Liaocheng Peoples Hosp, Dept Orthopaed Surg, Liaocheng, Peoples R China
关键词
Calcaneal fracture; Percutaneous screw fixation; Sustentaculum tali; Digital measurement; SANDERS TYPE-II; PLACEMENT; FIXATION;
D O I
10.1186/s12891-023-06748-5
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Background In calcaneal fractures, the percutaneous screw fixation (PSF) is currently considered to be the better choice, but it is difficult to accurately place the screw into the sustentaculum tali (ST) during the operation. In this study, the ideal entry point, angle, diameter and length of the screw were calculated by simulating the operation process. Methods We retrospectively collected the calcaneus computed tomography (CT) scans of 180 adults, DICOM-formatted CT-scan images of each patient were imported into Mimics software to establish calcaneus model. Virtual screws were placed on the lateral of the posterior talar articular surface (PTAS), the lateral edge of the anterior process of calcaneus (APC), and the calcaneal tuberosity, respectively, the trajectory and size of the screws were calculated. Results The mean maximum diameter of the PTAS screw was 42.20 +/- 3.71 mm. The vertical distance between the midpoint of the APC optimal screw trajectory and the lowest point of the tarsal sinus was 10.67 +/- 1.84 mm, and the distance between the midpoint of the APC optimal screw trajectory and the calcaneocuboid joint was 5 mm similar to 19.81 +/- 2.08 mm. The mean maximum lengths of APC screws was 44.69 +/- 4.81 mm, and the Angle between the screw and the coronal plane of the calcaneus from proximal to distal was 4.72 degrees +/- 2.15 degrees to 20.52 degrees +/- 3.77 degrees. The optimal point of the maximum diameter of the calcaneal tuberosity screw was located at the lateral border of the achilles tendon endpoint. The mean maximum diameters of calcaneal tuberosity screws was 4.46 +/- 0.85 mm, the mean maximum lengths of screws was 65.31 +/- 4.76 mm. We found gender- dependent differences for the mean maximum diameter and the maximum length of the three screws. Conclusions The study provides effective positioning for percutaneous screw fixation of calcaneal fractures. For safer and more efficient screw placement, we suggest individualised preoperative 3D reconstruction simulations. Further biomechanical studies are needed to verify the function of the screw.
引用
收藏
页数:7
相关论文
共 50 条
  • [21] Internal fixation of calcaneal fractures with intraoperative 3D X-ray monitoring
    Porte, T.
    Haustedt, N.
    Queitsch, C.
    Juergens, C.
    TRAUMA UND BERUFSKRANKHEIT, 2005, 7 : S162 - S166
  • [22] Improved therapy of calcaneal fractures by intraoperative 3D-fluoroscopy and locked-screw plate fixation
    Queitsch C.
    Schulz A.P.
    Haustedt N.
    Simon L.
    Fuchs S.
    European Journal of Trauma, 2006, 32 (5): : 471 - 476
  • [23] Minimally invasive treatment of calcaneal fractures via the sinus tarsi approach based on a 3D printing technique
    Yao, Lufeng
    Wang, Haiqing
    Zhang, Feng
    Wang, Liping
    Dong, Jianghui
    MATHEMATICAL BIOSCIENCES AND ENGINEERING, 2019, 16 (03) : 1597 - 1610
  • [24] An intraoperative 3D image-based navigation error during cervical pedicle screw insertion
    Nakashima, Hiroaki
    Ishikawa, Yoshimoto
    Ando, Kei
    Kobayashi, Kazuyoshi
    Ishiguro, Naoki
    Imagama, Shiro
    NAGOYA JOURNAL OF MEDICAL SCIENCE, 2020, 82 (04): : 799 - 805
  • [25] Establishment of fluoroscopy views and standardized procedure of percutaneous magic screw insertion for acetabulum fractures
    Li, Jiantao
    Li, Zhirui
    Wang, Xiang
    Zhang, Gongzi
    Peng, Ye
    Zhang, Shuwei
    Tang, Peifu
    Zhang, Lihai
    BMC MUSCULOSKELETAL DISORDERS, 2018, 19
  • [26] Comparison of the Conventional Surgery and the Surgery Assisted by 3d Printing Technology in the Treatment of Calcaneal Fractures
    Zheng, Wenhao
    Tao, Zhenyu
    Lou, Yiting
    Feng, Zhenhua
    Li, Hang
    Cheng, Liang
    Zhang, Hui
    Wang, Jianshun
    Guo, Xiaoshan
    Chen, Hua
    JOURNAL OF INVESTIGATIVE SURGERY, 2018, 31 (06) : 557 - 567
  • [27] Maintenance of Integrity of Upper Facet Joints during Simulated Percutaneous Pedicle Screw Insertion Using 2D versus 3D Planning
    Archavlis, Eleftherios
    Ringel, Florian
    Kantelhardt, Sven
    JOURNAL OF NEUROLOGICAL SURGERY PART A-CENTRAL EUROPEAN NEUROSURGERY, 2019, 80 (04) : 269 - 276
  • [28] Accuracy of 3D fluoroscopy-navigated anterior transpedicular screw insertion in the cervical spine: an experimental study
    Bredow, Jan
    Meyer, Carolin
    Scheyerer, Max Joseph
    Siedek, Florian
    Mueller, Lars Peter
    Eysel, Peer
    Stein, Gregor
    EUROPEAN SPINE JOURNAL, 2016, 25 (06) : 1683 - 1689
  • [29] Combined 3D Printed Template to Guide Iliosacral Screw Insertion for Sacral Fracture and Dislocation: A Retrospective Analysis
    Wu, Chao
    Deng, Jia-yan
    Li, Tao
    Tan, Lun
    Yuan, De-chao
    ORTHOPAEDIC SURGERY, 2020, 12 (01) : 241 - 247
  • [30] Modified Technique of Percutaneous Posterior Columnar Screw Insertion and Neutralization Plate for Complex Acetabular Fractures
    Yu, Yi-Hsun
    Tseng, I-Chuan
    Su, Chun-Yi
    Huang, Jau-Wen
    Wu, Chi-Chung
    JOURNAL OF TRAUMA-INJURY INFECTION AND CRITICAL CARE, 2011, 71 (01): : 198 - 203