Optimization of a fast deuterium diagnostic method based on visible energetic 3He spectroscopy for high electron density plasmas

被引:0
|
作者
Kimura, K. [1 ]
Matsuura, H. [1 ]
Itoh, C. [1 ]
Kawamoto, Y. [2 ]
Oishi, T. [3 ]
Goto, M. [2 ,4 ]
Ogawa, K. [2 ,4 ]
Nishitani, T. [5 ]
Isobe, M. [2 ,4 ]
Osakabe, M. [2 ,4 ]
机构
[1] Kyushu Univ, Dept Appl Quantum Phys & Nucl Engn, 744 Motooka, Fukuoka 8190395, Japan
[2] Natl Inst Nat Sci, Natl Inst Fus Sci, 322-6 Oroshi Cho, Toki 5095292, Japan
[3] Tohoku Univ, Dept Quantum Sci & Energy Engn, 6-6-01-2 Aobayama, Sendai 9808579, Japan
[4] Grad Univ Adv Studies, Dept Fus Sci, SOKENDAI, 322-6 Oroshi Cho, Toki 5095292, Japan
[5] Nagoya Univ, Grad Sch Engn, Furo Cho,Chikusa Ku, Nagoya 4648603, Japan
来源
REVIEW OF SCIENTIFIC INSTRUMENTS | 2023年 / 94卷 / 06期
关键词
INJECTION; BEAM;
D O I
10.1063/5.0110088
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
Fast ions play a crucial role in plasma heating, and their behavior in the plasma must be accurately understood. A diagnostics method based on charge exchange emission from the n = 4 - 3 transition (?(0) = 468.6 nm) of energetic He-3 produced by the deuteron-deuteron reaction has been proposed as a for fast deuterons with energies in the order of MeV. The proposed method has the following advantages: No beam emission interferes with the spectra, the direction of the measuring line of sight, and the injection angle of the diagnostic beam can be freely determined. In previous studies, due to competing bremsstrahlung, it was expected that the proposed method will not be practical in the case of high electron density operation. This paper makes the proposed method available for measurement even at high electron densities by optimizing the measurement line of sight direction and the diagnostic beam incidence angle. This allows an electron density five times larger than the range of applications shown in previous studies. This result will contribute to measure of DT alpha in ITER.
引用
收藏
页数:10
相关论文
共 8 条
  • [1] Diagnostics Method for 2-D Velocity Distribution Function of Beam Deuterons Using Visible Light of Energetic 3He in Deuterium Plasmas
    Kimura, Kento
    Matsuura, Hideaki
    Itoh, Chujo
    IEEE TRANSACTIONS ON PLASMA SCIENCE, 2021, 49 (10) : 3142 - 3148
  • [2] Fast deuteron diagnostics using visible light spectra of 3He produced by deuteron-deuteron reaction in deuterium plasmas
    Kimura, K.
    Matsuura, H.
    Kawamoto, Y.
    Oishi, T.
    Goto, M.
    Ogawa, K.
    Nishitani, T.
    Isobe, M.
    Osakabe, M.
    REVIEW OF SCIENTIFIC INSTRUMENTS, 2021, 92 (05):
  • [3] Study on Fast Deuteron Diagnostics Method Using Fast 3He Visible Spectra in the Large Helical Device Deuterium Plasma
    Kimura, Kento
    Matsuura, Hideaki
    Itoh, Chujo
    Kawamoto, Yasuko
    Oishi, Tetsutaro
    Goto, Motoshi
    Ogawa, Kunihiro
    Nishitani, Takeo
    Isobe, Mitsutaka
    Osakabe, Masaki
    PLASMA AND FUSION RESEARCH, 2023, 18
  • [4] Constraining the 3He + 3He Gamow energy probed in high energy density plasmas at the National Ignition Facility
    Adrian, P. J.
    Bachmann, B.
    Casey, D. T.
    Craxton, R. S.
    Garbett, W.
    Johnson, M. Gatu
    Hartouni, E.
    Hohenberger, M.
    Holunga, D.
    Kabadi, N. V.
    Khan, S.
    Kunimune, J.
    Lahmann, B.
    Sutcliffe, G. D.
    Whitley, H. D.
    Zylstra, A.
    Frenje, J. A.
    PHYSICS OF PLASMAS, 2025, 32 (02)
  • [5] 2H(p, γ)3He cross section measurement using high-energy-density plasmas
    Zylstra, A. B.
    Herrmann, H. W.
    Kim, Y. H.
    McEvoy, A.
    Frenje, J. A.
    Johnson, M. Gatu
    Petrasso, R. D.
    Glebov, V. Yu
    Forrest, C.
    Delettrez, J.
    Gales, S.
    Rubery, M.
    PHYSICAL REVIEW C, 2020, 101 (04)
  • [6] A fast method for the calculation of electron number density and temperature in laser-induced breakdown spectroscopy plasmas using artificial neural networks
    Borges, Fabio O.
    Cavalcanti, Gildo H.
    Gomes, Gabriela C.
    Palleschi, Vincenzo
    Mello, Alexandre
    APPLIED PHYSICS B-LASERS AND OPTICS, 2014, 117 (01): : 437 - 444
  • [7] A fast method for the calculation of electron number density and temperature in laser-induced breakdown spectroscopy plasmas using artificial neural networks
    Fábio O. Borges
    Gildo H. Cavalcanti
    Gabriela C. Gomes
    Vincenzo Palleschi
    Alexandre Mello
    Applied Physics B, 2014, 117 : 437 - 444
  • [8] Fast and sensitive low density solvent-based dispersive liquid-liquid microextraction method combined with high-performance liquid chromatography for determining cholecalciferol (vitamin D3) in milk and yogurt drink samples
    Kamankesh, Marzieh
    Shahdoostkhany, Mehrnoosh
    Mohammadi, Abdorreza
    Mollahosseini, Afsaneh
    ANALYTICAL METHODS, 2018, 10 (09) : 975 - 982