Measurement of Optic Nerve Sheath Diameter by Computed Tomography in the Pediatric Population: Normal Values

被引:1
|
作者
Akturk, Yeliz [1 ,2 ]
Simsir, Begum Demirler [1 ]
Hekimo, Baki [1 ]
机构
[1] Hlth Sci Univ Diskapi Yildirim Beyazit Training &, Dept Radiol, Ankara, Turkiye
[2] Hlth Sci Univ Diskapi Yildirim Beyazit Training &, Dept Radiol, Sehit Omerhalisdemir St, TR-06120 Ankara, Turkiye
关键词
INTRACRANIAL-PRESSURE; INJURY; SONOGRAPHY; ORBIT;
D O I
10.3928/01913913-20230331-02
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
Purpose: To determine the normal values of optic nerve sheath diameter (ONSD) by computed tomogra-phy (CT) in the pediatric population.Methods: The CT scans of pediatric patients aged 1 to 16 years who underwent brain CT for different reasons, who did not have intracranial pathology or increased intracranial pressure, and who had no pathology on CT were included in the study. Four age groups were de-fined with the following ranges: 1 to 2, 3 to 6, 7 to 10, and 11 to 16 years. ONSD was measured from axial CT images, 3 and 10 mm behind the optic globe.Results: The normative values of ONSD measured on CT imaging in children aged 1 to 16 years were reported. The change in ONSD according to age was investigated. ONSD was found to increase with age at both levels measured. The difference was statistically significant. Conclusions: Normal values should be known to de-tect pathologies that may cause an increase in optic nerve diameter. The values reported in this study can serve as a reference for normal optic nerve sheath di-ameter in the pediatric age group.
引用
收藏
页码:38 / 43
页数:6
相关论文
共 50 条
  • [1] Transorbital Sonographic Measurement of Normal Optic Sheath Nerve Diameter in Nigerian Adult Population
    Anas, Ismail
    MALAYSIAN JOURNAL OF MEDICAL SCIENCES, 2014, 21 (05): : 24 - 29
  • [2] Bedside Ultrasonography as an Alternative to Computed Tomography Scan for the Measurement of Optic Nerve Sheath Diameter
    Yanamandra, Uday
    Gupta, Amul
    Yanamandra, Sushma
    Das, Subrat Kumar
    Patyal, Sagarika
    Nair, Velu
    JOURNAL OF NEUROSCIENCES IN RURAL PRACTICE, 2018, 9 (02) : 252 - 255
  • [3] Transorbital ultrasound measurement of optic nerve sheath diameter in normal rabbits
    Yang, Xi-Yue
    Yang, Jin-Ping
    Zhu, Lin-Ping
    Pan, Rui-Hui
    Huang, Yan-Ni
    Li, Zhi-Xian
    INTERNATIONAL JOURNAL OF CLINICAL AND EXPERIMENTAL MEDICINE, 2017, 10 (09): : 13412 - 13418
  • [4] Interrater reliability of emergency medicine residents in measurement of optic nerve sheath diameter with computed tomography
    Yilmaz, Irem Olcay
    Aksay, Ersin
    Bayram, Basak
    Oray, Nese Colak
    Karabay, Nuri
    TURKISH JOURNAL OF EMERGENCY MEDICINE, 2021, 21 (03): : 117 - 121
  • [5] Ultrasound measurement of optic nerve diameter and optic nerve sheath diameter in healthy Chinese adults
    Chen, Han
    Ding, Gui-Sheng
    Zhao, Yan-Chun
    Yu, Rong-Guo
    Zhou, Jian-Xin
    BMC NEUROLOGY, 2015, 15
  • [6] Determination of normal values of optic nerve sheath diameter in newborns with bedside ultrasonography
    Yapicioglu, Hacer
    Aslan, Nagehan
    Sertdemir, Yasar
    Yildizdas, Dincer
    Gulasi, Selvi
    Mert, Kurthan
    EARLY HUMAN DEVELOPMENT, 2020, 145
  • [7] Correlation of optic nerve sheath diameter measurements by computed tomography and magnetic resonance imaging
    Kalantari, Hossein
    Jaiswal, Rajnish
    Bruck, Isaac
    Matari, Hussein
    Ghobadi, Farzaneh
    Weedon, Jeremy
    Hassen, Getaw Worku
    AMERICAN JOURNAL OF EMERGENCY MEDICINE, 2013, 31 (11) : 1595 - 1597
  • [8] Variability of the optic nerve sheath diameter on brain computed tomography in Turkish children based on sex and age
    Bardak, Sefika
    Berksoy, Emel
    Cicek, Alper
    Demir, Guelsah
    Pekcevik, Yeliz
    Elibol, Pelin
    Verdi, Ezgi Guvel
    Gökalp, Gamze
    Nalbant, Tugce
    Emir, Busra
    CHILDS NERVOUS SYSTEM, 2023, 39 (12) : 3551 - 3560
  • [9] Comparison of ultrasonography and computed tomography for measuring optic nerve sheath diameter for the detection of elevated intracranial pressure
    Kim, Dae Yong
    Kim, Sin Young
    Hong, Dae Young
    Sung, Bo Youn
    Lee, Sung
    Paik, Jin Hui
    Jung, Hyun Min
    CLINICAL NEUROLOGY AND NEUROSURGERY, 2021, 204
  • [10] Ultrasound optic nerve sheath diameter measurement in optic neuritis
    De Bernardo, Maddalena
    Vitiello, Livio
    Kumar, Akshay
    AMERICAN JOURNAL OF EMERGENCY MEDICINE, 2019, 37 (08) : 1595 - 1596