Electrochemical detection of cortisol using a structure-switching aptamer immobilized on gold nanoparticles-modified screen-printed electrodes

被引:9
|
作者
Sharma, Vipasha [1 ,2 ]
Sharma, Tarun Kumar [3 ]
Kaur, Inderpreet [1 ,2 ]
机构
[1] CSIR, Cent Sci Instruments Org, Biomol Elect & Nanotechnol Grp, Sect 30 C, Chandigarh 160030, India
[2] Acad Sci & Innovat Res AcSIR, Ghaziabad 201002, India
[3] Gujarat Biotechnol Univ, Dept Med Biotechnol, Gandhinagar 382355, Gujarat, India
关键词
Electrochemical aptasensor; Stress; Cortisol; Aptamer; Gold nanoparticle; APTASENSOR; ASSAY; BIOSENSOR; POINT;
D O I
10.1007/s10800-023-01881-4
中图分类号
O646 [电化学、电解、磁化学];
学科分类号
081704 ;
摘要
This paper demonstrated the fabrication of an electrochemical-based aptasensor for the specific detection of the stress hormone "Cortisol" in Saliva. Gold nanoparticles have been widely explored as an immobilization substrate for the aptamer due to the direct covalent attachment through thiol bonding. Here, cortisol-specific truncated 14-mer aptamer was immobilized onto the gold nanoparticles-decorated screen-printed electrodes. The aptasensor has a broad dynamic range of 0.1 pg/ ml-100 ng/ml with a detection limit of 0.25 pg/ml in buffer and 0.28 pg/ml in artificial saliva matrix. The sensitivity of the sensor was 1.53 mu A (pg/ml)(-1) in the buffer and 1.33 mu A (pg/ml)(-1) in the artificial saliva matrix. The proposed aptasensor has demonstrated high specificity towards cortisol and showed no change in the current signal towards the structural analogues of the cortisol. [GRAPHICS] .
引用
收藏
页码:1765 / 1776
页数:12
相关论文
共 50 条
  • [31] Electrochemical Detection of SARS-CoV-2 Using Immunomagnetic Separation and Gold Nanoparticles on Unmodified Screen-Printed Carbon Electrodes
    Lambert, Christopher J.
    Jayamohan, Harikrishnan
    Gale, Bruce K.
    Laurentius, Lars B.
    Patel, Dhruv
    Hansen, Madison
    Mahmood, Tawsif
    Sant, Himanshu Jayant
    APPLIED SCIENCES-BASEL, 2023, 13 (18):
  • [32] Impedimetric determination of cortisol using screen-printed electrode with aptamer-modified magnetic beads
    Pusomjit, Pannaporn
    Teengam, Prinjaporn
    Thepsuparungsikul, Nichanan
    Sanongkiet, Sucharat
    Chailapakul, Orawon
    MICROCHIMICA ACTA, 2021, 188 (02)
  • [33] Impedimetric determination of cortisol using screen-printed electrode with aptamer-modified magnetic beads
    Pannaporn Pusomjit
    Prinjaporn Teengam
    Nichanan Thepsuparungsikul
    Sucharat Sanongkiet
    Orawon Chailapakul
    Microchimica Acta, 2021, 188
  • [34] Iridium oxide-modified reference screen-printed electrodes for point-of-care portable electrochemical cortisol detection
    Ji, Tong
    Ye, Wen
    Xiao, Weiyu
    Dawson, Graham
    Dong, Qiuchen
    Gwenin, Christopher
    TALANTA, 2024, 280
  • [35] Modified Gold Screen-Printed Electrodes for the Determination of Heavy Metals
    Celesti, Consuelo
    Giofre, Salvatore Vincenzo
    Espro, Claudia
    Legnani, Laura
    Neri, Giovanni
    Iannazzo, Daniela
    SENSORS, 2024, 24 (15)
  • [36] Cortisol Detection in Undiluted Human Serum Using a Sensitive Electrochemical Structure-Switching Aptamer over an Antifouling Nanocomposite Layer
    Singh, Naveen K.
    Chung, Saeromi
    Sveiven, Michael
    Hall, Drew A.
    ACS OMEGA, 2021, 6 (42): : 27888 - 27897
  • [37] Electrochemical stability of screen-printed electrodes modified with Au nanoparticles for detection of methicillin-resistant Staphylococcus aureus
    Vu Quang Khue
    Tran Quang Huy
    Vu Ngoc Phan
    Anh Tuan-Le
    Dang Thi Thanh Le
    Tonezzer, Matteo
    Nguyen Thi Hong Hanh
    MATERIALS CHEMISTRY AND PHYSICS, 2020, 255
  • [38] Electrochemical Biosensor for Detection of Adenosine Based on Structure-Switching Aptamer and Amplification with Reporter Probe DNA Modified Au Nanoparticles
    Zhang, Shusheng
    Xia, Jianping
    Li, Xuemei
    ANALYTICAL CHEMISTRY, 2008, 80 (22) : 8382 - 8388
  • [39] A Lab Prototype for Rapid Electrochemical Detection of Escherichia coli in Water Using Modified Screen-Printed Electrodes
    Chalka, Vandana Kumari
    Mishra, Akanksha
    Chhabra, Meenu
    Rangra, Kamaljit
    Dhanekar, Saakshi
    ACS APPLIED BIO MATERIALS, 2024, 7 (11): : 7269 - 7279
  • [40] Amperometric determination of sulfite using screen-printed electrodes modified with metallic nanoparticles
    Begoña Molinero-Abad
    María Asunción Alonso-Lomillo
    Olga Domínguez-Renedo
    María Julia Arcos-Martínez
    Microchimica Acta, 2013, 180 : 1351 - 1355