Implementation and analysis of mono inverter-battery configuration for wind driven doubly fed induction generator

被引:0
作者
Muthusamy, Kaleeswari [1 ,2 ]
Muthusamy, Madheswaran [1 ]
机构
[1] Muthayammal Engn Coll, Ctr Res Signal & Image Proc, Dept Elect & Commun Engn, Rasipuram, India
[2] Muthayammal Engn Coll, Ctr Res Signal & Image Proc, Dept Elect & Commun Engn, Rasipuram 637408, India
关键词
Wind energy; energy conversion; renewable energy; power conversion; power control; SENSORLESS CONTROL; POWER-GENERATION;
D O I
10.1080/15567036.2023.2205824
中图分类号
TE [石油、天然气工业]; TK [能源与动力工程];
学科分类号
0807 ; 0820 ;
摘要
This paper investigates the controller implementation and analysis of Doubly Fed Induction Generator (DFIG) for powering isolated loads in rural electrification. A simple speed sensorless algorithm-assisted controller for isolated power supply of DFIG has been proposed using a digital controller and voltage source converter at the rotor terminals of the generator. The controller can automatically correct the voltage and frequency of the rotor side inverter pulse to obtain a desired voltage and frequency at stator side despite the variations in the wind speed and load. A hardware prototype of the system has been built and tested on a prototype machine, which is driven by an emulated wind turbine under sub-synchronous and super-synchronous speed operations. The detailed results of both simulated and hardware waveforms are provided in the paper to demonstrate the working of the proposed topology and embedded control scheme. Further, the performance characteristics of DFIG are modeled and verified experimentally. A good agreement exists between theoretical and experimental results.
引用
收藏
页码:4593 / 4615
页数:23
相关论文
共 50 条
[31]   Advanced control of a doubly-fed induction generator for wind energy conversion [J].
Poitiers, F. ;
Bouaouiche, T. ;
Machmoum, M. .
ELECTRIC POWER SYSTEMS RESEARCH, 2009, 79 (07) :1085-1096
[32]   Nonlinear control of the doubly-fed induction generator in wind power systems [J].
Soares, Orlando ;
Goncalves, Henrique ;
Martins, Antonio ;
Carvalho, Adriano .
RENEWABLE ENERGY, 2010, 35 (08) :1662-1670
[33]   Modelling and dynamic state estimation of a doubly fed induction generator wind turbine [J].
Shahriari, Sayyed Ali Akbar .
COMPEL-THE INTERNATIONAL JOURNAL FOR COMPUTATION AND MATHEMATICS IN ELECTRICAL AND ELECTRONIC ENGINEERING, 2020, 39 (06) :1393-1409
[34]   Control of A Doubly-Fed Induction Generator for Wind Energy Conversion System [J].
Boubzizi, Said ;
El Hajjaji, Ahmed ;
Abid, Hafedh ;
Chaabane, Mohamed .
IECON 2017 - 43RD ANNUAL CONFERENCE OF THE IEEE INDUSTRIAL ELECTRONICS SOCIETY, 2017, :8773-8778
[35]   Parameter Tuning for Wind Turbine with Doubly Fed Induction Generator Using PSO [J].
Wu, F. ;
Ju, P. ;
Zhang, X. P. .
2010 ASIA-PACIFIC POWER AND ENERGY ENGINEERING CONFERENCE (APPEEC), 2010,
[36]   Modeling and simulation of power controller for the doubly fed induction generator wind turbines [J].
State Key Lab. of Power Systems, Department of Electrical Engineering, Tsinghua University, Beijing 100084, China ;
不详 ;
不详 ;
不详 .
Dianli Xitong Zidonghue, 2007, 24 (34-37+41) :34-37
[37]   Doubly fed induction generator model for transient stability analysis [J].
Ledesma, P ;
Usaola, J .
IEEE TRANSACTIONS ON ENERGY CONVERSION, 2005, 20 (02) :388-397
[38]   Fault Ride Through Analysis of Grid Connected Doubly Fed Induction Generator Based Wind System [J].
Gururaj, M. V. ;
Padhy, Narayana Prasad .
2018 IEEE POWER & ENERGY SOCIETY GENERAL MEETING (PESGM), 2018,
[39]   Stability Analysis of Doubly-Fed Induction Wind Generator Operating at Low Power Factor Mode [J].
Zheng, Yanwen ;
Li, Yongdong ;
Chai, Jianyun .
IECON 2008: 34TH ANNUAL CONFERENCE OF THE IEEE INDUSTRIAL ELECTRONICS SOCIETY, VOLS 1-5, PROCEEDINGS, 2008, :2170-2175
[40]   Synchronizing Control of Wind Turbine Driven Doubly Fed Induction Generator System with DG in Remote Area Involving Solar PV-Battery Energy Storage [J].
Puchalapalli, Sambasivaiah ;
Singh, Bhim .
2021 IEEE ENERGY CONVERSION CONGRESS AND EXPOSITION (ECCE), 2021, :497-503