Accuracy and repeatability of the Microsoft Azure Kinect for clinical measurement of motor function

被引:31
作者
Bertram, Johannes [1 ]
Krueger, Theresa [2 ]
Roehling, Hanna Marie [2 ]
Jelusic, Ante [1 ]
Mansow-Model, Sebastian [2 ]
Schniepp, Roman M. [1 ,3 ]
Wuehr, Max M. [1 ]
Otte, Karen [2 ]
机构
[1] Ludwig Maximilians Univ Munchen, German Ctr Vertigo & Balance Disorders DSGZ, Munich, Germany
[2] Motognosis GmbH, Berlin, Germany
[3] Ludwig Maximilians Univ Munchen, Dept Neurol, Munich, Germany
关键词
XBOX ONE KINECT; CONCURRENT VALIDITY; RELIABILITY; TRACKING;
D O I
10.1371/journal.pone.0279697
中图分类号
O [数理科学和化学]; P [天文学、地球科学]; Q [生物科学]; N [自然科学总论];
学科分类号
07 ; 0710 ; 09 ;
摘要
Quantitative assessment of motor function is increasingly applied in fall risk stratification, diagnosis, and disease monitoring of neuro-geriatric disorders of balance and gait. Its broad application, however, demands for low-cost and easy to use solutions that facilitate high-quality assessment outside laboratory settings. In this study, we validated in 30 healthy adults (12 female, age: 32.5 [22 - 62] years) the performance and accuracy of the latest generation of the Microsoft RGB-D camera, i.e., Azure Kinect (AK), in tracking body motion and providing estimates of clinical measures that characterise static posture, postural transitions, and locomotor function. The accuracy and repeatability of AK recordings was validated with a clinical reference standard multi-camera motion capture system (Qualisys) and compared to its predecessor Kinect version 2 (K2). Motion signal quality was evaluated by Pearson's correlation and signal-to-noise ratios while the accuracy of estimated clinical parameters was described by absolute and relative agreement based on intraclass correlation coefficients. The accuracy of AK-based body motion signals was moderate to excellent (RMSE 89 to 20 mm) and depended on the dimension of motion (highest for anterior-posterior dimension), the body region (highest for wrists and elbows, lowest for ankles and feet), and the specific motor task (highest for stand up and sit down, lowest for quiet standing). Most derived clinical parameters showed good to excellent accuracy (r .84 to .99) and repeatability (ICC(1,1) .55 to .94). The overall performance and limitations of body tracking by AK were comparable to its predecessor K2 in a cohort of young healthy adults. The observed accuracy and repeatability of AK-based evaluation of motor function indicate the potential for a broad application of high-quality and long-term monitoring of balance and gait in different non-specialised environments such as medical practices, nursing homes or community centres.
引用
收藏
页数:15
相关论文
共 27 条
[1]   Evaluation of the Pose Tracking Performance of the Azure Kinect and Kinect v2 for Gait Analysis in Comparison with a Gold Standard: A Pilot Study [J].
Albert, Justin Amadeus ;
Owolabi, Victor ;
Gebel, Arnd ;
Brahms, Clemens Markus ;
Granacher, Urs ;
Arnrich, Bert .
SENSORS, 2020, 20 (18) :1-22
[2]   Quantifying Asymmetry in Gait: The Weighted Universal Symmetry Index to Evaluate 3D Ground Reaction Forces [J].
Alves, Sonia A. ;
Ehrig, Rainald M. ;
Raffalt, Peter C. ;
Bender, Alwina ;
Duda, Georg N. ;
Agres, Alison N. .
FRONTIERS IN BIOENGINEERING AND BIOTECHNOLOGY, 2020, 8
[3]   Validity of visual perceptive computing for static posturography in patients with multiple sclerosis [J].
Behrens, Janina R. ;
Mertens, Sebastian ;
Krueger, Theresa ;
Grobelny, Anuschka ;
Otte, Karen ;
Mansow-Model, Sebastian ;
Gusho, Elona ;
Paul, Friedemann ;
Brandt, Alexander U. ;
Schmitz-Huebsch, Tanja .
MULTIPLE SCLEROSIS JOURNAL, 2016, 22 (12) :1596-1606
[4]   The Role of Movement Analysis in Diagnosing and Monitoring Neurodegenerative Conditions: Insights from Gait and Postural Control [J].
Buckley, Christopher ;
Alcock, Lisa ;
McArdle, Riona ;
Rehman, Rana Zia Ur ;
Del Din, Silvia ;
Mazza, Claudia ;
Yarnall, Alison J. ;
Rochester, Lynn .
BRAIN SCIENCES, 2019, 9 (02)
[5]   Three-dimensional cameras and skeleton pose tracking for physical function assessment: A review of uses, validity, current developments and Kinect alternatives [J].
Clark, Ross A. ;
Mentiplay, Benjamin F. ;
Hough, Emma ;
Pua, Yong Hao .
GAIT & POSTURE, 2019, 68 :193-200
[6]   Reliability and concurrent validity of the Microsoft Xbox One Kinect for assessment of standing balance and postural control [J].
Clark, Ross A. ;
Pua, Yong-Hao ;
Oliveira, Cristino C. ;
Bower, Kelly J. ;
Thilarajah, Shamala ;
McGaw, Rebekah ;
Hasanki, Ksaniel ;
Mentiplay, Benjamin F. .
GAIT & POSTURE, 2015, 42 (02) :210-213
[7]   A roadmap for implementation of patient-centered digital outcome measures in Parkinson's disease obtained using mobile health technologies [J].
Espay, Alberto J. ;
Hausdorff, Jeffrey M. ;
Sanchez-Ferro, Alvaro ;
Klucken, Jochen ;
Merola, Aristide ;
Bonato, Paolo ;
Paul, Serene S. ;
Horak, Fay B. ;
Vizcarra, Joaquin A. ;
Mestre, Tiago A. ;
Reilmann, Ralf ;
Nieuwboer, Alice ;
Dorsey, E. Ray ;
Rochester, Lynn ;
Bloem, Bastiaan R. ;
Maetzler, Walter .
MOVEMENT DISORDERS, 2019, 34 (05) :657-663
[8]   Technology in Parkinson's disease: Challenges and opportunities [J].
Espay, Alberto J. ;
Bonato, Paolo ;
Nahab, Fatta B. ;
Maetzler, Walter ;
Dean, John M. ;
Klucken, Jochen ;
Eskofier, Bjoern M. ;
Merola, Aristide ;
Horak, Fay ;
Lang, Anthony E. ;
Reilmann, Ralf ;
Giuffrida, Joe ;
Nieuwboer, Alice ;
Horne, Malcolm ;
Little, Max A. ;
Litvan, Irene ;
Simuni, Tanya ;
Dorsey, E. Ray ;
Burack, Michelle A. ;
Kubota, Ken ;
Kamondi, Anita ;
Godinho, Catarina ;
Daneault, Jean-Francois ;
Mitsi, Georgia ;
Krinke, Lothar ;
Hausdorff, Jeffery M. ;
Bloem, Bastiaan R. ;
Papapetropoulos, Spyros .
MOVEMENT DISORDERS, 2016, 31 (09) :1272-1282
[9]   Kinematic Validation of a Multi-Kinect v2 Instrumented 10-Meter Walkway for Quantitative Gait Assessments [J].
Geerse, Daphne J. ;
Coolen, Bert H. ;
Roerdink, Melvyn .
PLOS ONE, 2015, 10 (10)
[10]   Motor and Non-Motor Symptoms in Parkinson's Disease: Effects on Quality of Life [J].
Gokcal, Elif ;
Gur, Veysel Eren ;
Selvitop, Rabia ;
Babacan Yildiz, Gulsen ;
Asil, Talip .
NOROPSIKIYATRI ARSIVI-ARCHIVES OF NEUROPSYCHIATRY, 2017, 54 (02) :143-148