Objective: This retrospective study constitutes a feasibility assessment of dynamic conformal arc (DCA) therapy as an alter-native to volumetric-modulated arc therapy (VMAT) for stereotactic body radiation therapy (SBRT) of lung cancer (LC) with the free breathing technique using internal target volume. DCA is to create a more efficient treatment reducing beam-on time (BOT) and monitor unit (MU) without interplay errors except for complex tumor geometries when compared to volumetric modulated arc therapy (VMAT).Materials and Methods: CT images and plans of forty patients treated with 50 Gy prescription in four fractions using VMAT technique for SBRT treatment of LC selected. Plans were re-planned with using DCA technique. VMAT and DCA plans compared via The Radiation Therapy Oncology Group (RTOG) Protocol 0915 for conformity and efficient having pass rate of gamma index in quality assurance (QA), MU and BOT.Results: The study included 40 patients. The mean value of QA pass rate 99.10 +/- 1.49 in DCA and 92.34 +/- 1.96 in VMAT. The rate was higher in DCA (p<0.001 and t=8.98). The values of BOT and MU were 4.68 min and 3296 in the VMAT tech-nique and they were 3.58 min and 2395 in DCA. These values were significantly improved with DCA (p<0.001 and p<0.001).Conclusion: DCA can potentially minimize multi-leaf collimator errors from respiratory motion and small-field dosimetry. It delivery similar doses of treatment quality to tumor while providing faster treatment by significantly reducing MU and BOT compared to VMAT and moreover offers same-day SBRT treatments without the need for specific QA.
引用
收藏
页码:19 / 24
页数:6
相关论文
共 50 条
  • [31] Stereotactic Body Radiotherapy: Volumetric Modulated Arc Therapy Versus 3D Non-coplanar Conformal Radiotherapy for the Treatment of Early Stage Lung Cancer
    Herbert, C.
    Kwa, W.
    Nakano, S.
    James, K.
    Moiseenko, V.
    Wu, J.
    Schellenberg, D.
    Liu, M.
    [J]. TECHNOLOGY IN CANCER RESEARCH & TREATMENT, 2013, 12 (06) : 511 - 516
  • [32] Dosimetric and Clinical Benefits of Conformal Radiotherapy Plus Volumetric Modulated Arc Therapy in the Treatment of Non-small Cell Lung Cancer
    Jin, Xiance
    Xie, Congying
    [J]. WORLD CONGRESS ON MEDICAL PHYSICS AND BIOMEDICAL ENGINEERING, 2015, VOLS 1 AND 2, 2015, 51 : 392 - 396
  • [33] Volumetric modulated arc planning for lung stereotactic body radiotherapy using conventional and unflattened photon beams: a dosimetric comparison with 3D technique
    Zhang, Geoffrey G.
    Ku, Lichung
    Dilling, Thomas J.
    Stevens, Craig W.
    Zhang, Ray R.
    Li, Weiqi
    Feygelman, Vladimir
    [J]. RADIATION ONCOLOGY, 2011, 6
  • [34] Volumetric modulated arc planning for lung stereotactic body radiotherapy using conventional and unflattened photon beams: a dosimetric comparison with 3D technique
    Geoffrey G Zhang
    Lichung Ku
    Thomas J Dilling
    Craig W Stevens
    Ray R Zhang
    Weiqi Li
    Vladimir Feygelman
    [J]. Radiation Oncology, 6
  • [35] Dosimetric evaluation of four-dimensional dose distributions of CyberKnife and volumetric-modulated arc radiotherapy in stereotactic body lung radiotherapy
    Chan, Mark K. H.
    Kwong, Dora L. W.
    Law, Gilbert M. L.
    Tam, Eric
    Tong, Anthony
    Lee, Venus
    Ng, Sherry C. Y.
    [J]. JOURNAL OF APPLIED CLINICAL MEDICAL PHYSICS, 2013, 14 (04): : 136 - 149
  • [36] Dosimetric impact of different CT datasets for stereotactic treatment planning using 3D conformal radiotherapy or volumetric modulated arc therapy
    Oechsner, Markus
    Odersky, Leonhard
    Berndt, Johannes
    Combs, Stephanie Elisabeth
    Wilkens, Jan Jakob
    Duma, Marciana Nona
    [J]. RADIATION ONCOLOGY, 2015, 10
  • [37] Dosimetric impact of different CT datasets for stereotactic treatment planning using 3D conformal radiotherapy or volumetric modulated arc therapy
    Markus Oechsner
    Leonhard Odersky
    Johannes Berndt
    Stephanie Elisabeth Combs
    Jan Jakob Wilkens
    Marciana Nona Duma
    [J]. Radiation Oncology, 10
  • [38] Flattening filter-free technique in volumetric modulated arc therapy for lung stereotactic body radiotherapy: A clinical comparison with the flattening filter technique
    Aoki, Shuri
    Yamashita, Hideomi
    Haga, Akihiro
    Nawa, Kanabu
    Imae, Toshikazu
    Takahashi, Wataru
    Abe, Osamu
    Nakagawa, Keiichi
    [J]. ONCOLOGY LETTERS, 2018, 15 (03) : 3928 - 3936
  • [39] Role of Volumetric-Modulated Arc Therapy with Flattening Filter Free Delivery in Lung Stereotactic Body Radiotherapy
    Liu, Hong-Wei
    Olivotto, Ivo
    Lau, Harold
    Nugent, Zoann
    Khan, Rao
    [J]. JOURNAL OF MEDICAL IMAGING AND RADIATION SCIENCES, 2016, 47 (02) : 155 - 159
  • [40] Intensity-modulated radiotherapy, coplanar volumetric-modulated arc, therapy, and noncoplanar volumetric-modulated arc therapy in, glioblastoma: A dosimetric comparison
    Hou, Yong
    Zhang, Yan
    Liu, Zhen
    Yv, Lili
    Liu, Kun
    Tian, Xiufang
    Lv, Yajuan
    [J]. CLINICAL NEUROLOGY AND NEUROSURGERY, 2019, 187