Corrosion resistance evaluation of biodegradable magnesium alloy vascular stents optimized by mechanical adapted polymer coating strategy

被引:18
作者
Shi, Liqian [1 ,2 ]
Chen, Shanshan [2 ]
Zheng, Feng [2 ]
Liu, Mingming [3 ]
Yang, Hui [2 ]
Zhang, Bingchun [2 ]
机构
[1] Univ Sci & Technol China, Sch Mat Sci & Engn, Shenyang 110016, Peoples R China
[2] Chinese Acad Sci, Inst Met Res, Shi changxu Innovat Ctr Adv Mat, Shenyang 110016, Peoples R China
[3] Shenyang Univ, Normal Coll, Shenyang 110044, Peoples R China
基金
中国国家自然科学基金;
关键词
Magnesium alloy; Cardiovascular stent; Mechanical adaptability; Corrosion resistance; Biodegradable polymer; IN-VITRO CORROSION; ABSORBABLE METAL SCAFFOLD; MG ALLOY; MICRO-TUBES; ZR ALLOY; BEHAVIOR; DEGRADATION; ARTERY; MICROSTRUCTURE; PERFORMANCE;
D O I
10.1016/j.colsurfa.2022.130664
中图分类号
O64 [物理化学(理论化学)、化学物理学];
学科分类号
070304 ; 081704 ;
摘要
Surface modification coating of magnesium alloy stents as a physical barrier is to inhibit the corrosive medium from contact with matrix. In view of the complex deformation behavior of stent, mechanical adopted polymer coating strategy was considered in our work. Here, a relatively high plasticity polymer-poly(butyl acrylate) (PBA) was applied as the outer protective layer on the surface of magnesium alloy discs and stents through a dip -coating method and ultrasonic spraying system respectively. Compared with low plasticity poly(d,L-lactide) (PDLLA) control group, mechanical property of PBA polymer film were detected, furthermore, the static corrosion behaviors of PBA/MgF2 flake samples were investigated by electrochemical and immersion tests for a period time. The morphologies and degradation behaviors of stents after grip-expansion were conducted to explore the mechanical adaptability of PBA/MgF2 coating with magnesium alloy stent. PBA/MgF2 composite coating could improve the corrosion resistance of both static and deformed magnesium alloys, exhibiting a long-term protection. Especially, PBA-coated stent maintained the structural integrity and a relatively smooth surface after 21 days of service. Therefore, it is inferred that a coating material with high elongation at break is more mechanical adaptability with stent deformation to reduce the degradation rate of magnesium alloy stents.
引用
收藏
页数:9
相关论文
共 46 条
[1]   Deposition of nanostructured fluorine-doped hydroxyapatite-polycaprolactone duplex coating to enhance the mechanical properties and corrosion resistance of Mg alloy for biomedical applications [J].
Bakhsheshi-Rad, H. R. ;
Hamzah, E. ;
Kasiri-Asgarani, M. ;
Jabbarzare, S. ;
Iqbal, N. ;
Kadir, M. R. Abdul .
MATERIALS SCIENCE & ENGINEERING C-MATERIALS FOR BIOLOGICAL APPLICATIONS, 2016, 60 :526-537
[2]   Hemocompatibility of soft hydrophobic poly(n-butyl acrylate) networks with elastic moduli adapted to the elasticity of human arteries [J].
Braune, S. ;
Hoenow, A. ;
Mrowietz, C. ;
Cui, J. ;
Kratz, K. ;
Hellwig, J. ;
Uezuem, C. ;
Klitzing, R. V. ;
Lendlein, A. ;
Jung, F. .
CLINICAL HEMORHEOLOGY AND MICROCIRCULATION, 2011, 49 (1-4) :375-390
[3]   Influence of a MAO plus PLGA coating on biocorrosion and stress corrosion cracking behavior of a magnesium alloy in a physiological environment [J].
Chen, Lianxi ;
Sheng, Yinying ;
Zhou, Hanyu ;
Li, Zhibin ;
Wang, Xiaojian ;
Li, Wei .
CORROSION SCIENCE, 2019, 148 :134-143
[4]   Assessment of structure integrity, corrosion behavior and microstructure change of AZ31B stent in porcine coronary arteries [J].
Chen, Shanshan ;
Zhang, Bin ;
Zhang, Bingchun ;
Lin, Hao ;
Yang, Hui ;
Zheng, Feng ;
Chen, Ming ;
Yang, Ke .
JOURNAL OF MATERIALS SCIENCE & TECHNOLOGY, 2020, 39 :39-47
[5]   A novel polymer critical re-melting treatment for improving corrosion resistance of magnesium alloy stent [J].
Chen, Shanshan ;
Wan, Peng ;
Zhang, Bingchun ;
Erisen, Deniz Eren ;
Yang, Hui ;
Yang, Ke .
JOURNAL OF MATERIALS SCIENCE & TECHNOLOGY, 2019, 35 (01) :19-22
[6]   In vitro corrosion resistance of layer-by-layer assembled polyacrylic acid multilayers induced Ca-P coating on magnesium alloy AZ31 [J].
Cui, Lan-Yue ;
Cheng, Shen-Cong ;
Liang, Lu-Xian ;
Zhang, Jing-Chao ;
Li, Shuo-Qi ;
Wang, Zhen-Lin ;
Zeng, Rong-Chang .
BIOACTIVE MATERIALS, 2020, 5 (01) :153-163
[7]   Corrosion resistance of a self-healing micro-arc oxidation/polymethyltrimethoxysilane composite coating on magnesium alloy AZ31 [J].
Cui, Lan-Yue ;
Gao, Shang-Dong ;
Li, Ping-Ping ;
Zeng, Rong-Chang ;
Zhang, Fen ;
Li, Shuo-Qi ;
Han, En-Hou .
CORROSION SCIENCE, 2017, 118 :84-95
[8]   Properties of polydimethylsiloxane hydrophobic modified duplex microarc oxidation/diamond-like carbon coatings on AZ31B Mg alloy [J].
Cui, Xue-Jun ;
Ning, Chuang-Ming ;
Zhang, Guang-An ;
Shang, Lun-Lin ;
Zhong, Li-Ping ;
Zhang, Ying-Jun .
JOURNAL OF MAGNESIUM AND ALLOYS, 2021, 9 (04) :1285-1296
[9]  
Friedrich J., 2010, MRS BULL, V35, P607
[10]   Evolution of metallic cardiovascular stent materials: A comparative study among stainless steel, magnesium and zinc [J].
Fu, Jiayin ;
Su, Yingchao ;
Qin, Yi-Xian ;
Zheng, Yufeng ;
Wang, Yadong ;
Zhu, Donghui .
BIOMATERIALS, 2020, 230