Atrial fibrillation detection on reconstructed photoplethysmography signals collected from a smartwatch using a denoising autoencoder

被引:4
作者
Mohagheghian, Fahimeh [1 ]
Han, Dong [1 ]
Ghetia, Om [1 ]
Chen, Darren [1 ]
Peitzsch, Andrew [1 ]
Nishita, Nishat [2 ]
Ding, Eric Y. [3 ]
Otabil, Edith Mensah [3 ]
Noorishirazi, Kamran [3 ]
Hamel, Alexander [3 ]
Dickson, Emily L. [4 ]
Dimezza, Danielle [3 ]
Tran, Khanh-Van [3 ]
Mcmanus, David D. [3 ]
Chon, Ki H. [1 ]
机构
[1] Univ Connecticut, Dept Biomed Engn, Storrs, CT 06269 USA
[2] Univ Connecticut Hlth, Dept Publ Hlth Sci, Farmington, CT USA
[3] Univ Massachusetts, Div Cardiol, Med Sch, Worcester, MA USA
[4] Des Moines Univ, Coll Osteopath Med, Des Moines, IA USA
关键词
Photoplethysmography; Atrial fibrillation; Deep learning; Denoising; Autoencoder; STROKE;
D O I
10.1016/j.eswa.2023.121611
中图分类号
TP18 [人工智能理论];
学科分类号
081104 ; 0812 ; 0835 ; 1405 ;
摘要
Photoplethysmography (PPG) signals collected by wearables have been shown to be effective in accurate detection of atrial fibrillation (AF), provided that the data are devoid of motion and noise artifacts (MNA). Many studies have been previously conducted to detect AF arrhythmia using PPG data; however, the subjects were mostly in clinics or controlled settings with data collection lasting several minutes to at most several hours with minimal MNA. Our study, Pulsewatch, differs from previous AF studies in that PPG data from smartwatches prescribed to stroke survivors were continuously collected for two weeks in real-life conditions, which invariably included a significant amount of MNA. Our aim is to provide a framework for a novel use of a denoising autoencoder to reconstruct motion-artifact-removed PPG signals so that we can improve the AF detection per-formance and to increase the amount of analyzable data.We used more than 30,000 25-sec PPG segments from 129 subjects randomly selected from Pulsewatch and Stanford University's datasets. The training and testing datasets from these two databases came from smart-watches from different vendors with varying sampling frequencies and time duration of recordings in diverse and realistic settings. In this study, the highly corrupted PPG data were automatically detected and discarded, but those segments contaminated with low-to-moderate motion and noise artifacts (MNA) were subjected to a convolutional denoising autoencoder (CDA). To reconstruct the artifact-removed PPG segments, we proposed to employ two distinct CDA models for AF and non-AF data groups initially classified as AF or non-AF. Using the proposed approach, we significantly improved the performance of detecting occult AF. We achieved classifica-tion accuracy, sensitivity, and specificity of 91.02%, 91.54%, and 90.85%, respectively, for out-of-sample test data from both databases. By sanitizing data from low-to-moderate MNA, we were able to increase the usable data coverage by 21%.
引用
收藏
页数:12
相关论文
共 34 条
  • [1] Akosa J., 2017, P SAS GLOB FOR, P1
  • [2] Atrial Fibrillation Detection from Wrist Photoplethysmography Signals Using Smartwatches
    Bashar, Syed Khairul
    Han, Dong
    Hajeb-Mohammadalipour, Shirin
    Ding, Eric
    Whitcomb, Cody
    McManus, David D.
    Chon, Ki H.
    [J]. SCIENTIFIC REPORTS, 2019, 9 (1)
  • [3] Bonomi AG, 2016, COMPUT CARDIOL CONF, V43, P277
  • [4] Estimates of Current and Future Incidence and Prevalence of Atrial Fibrillation in the US Adult Population
    Colilla, Susan
    Crow, Ann
    Petkun, William
    Singer, Daniel E.
    Simon, Teresa
    Liu, Xianchen
    [J]. AMERICAN JOURNAL OF CARDIOLOGY, 2013, 112 (08) : 1142 - 1147
  • [5] Smartwatch monitoring for atrial fibrillation after stroke-The Pulsewatch Study: Protocol for a multiphase randomized controlled trial
    Dickson, Emily L.
    Ding, Eric Y.
    Saczynski, Jane S.
    Han, Dong
    Moonis, Majaz
    Fitzgibbons, Timothy P.
    Barton, Bruce
    Chon, Ki
    McManus, David D.
    [J]. CARDIOVASCULAR DIGITAL HEALTH JOURNAL, 2021, 2 (04): : 231 - 241
  • [6] Ding EY, 2021, CIRCULATION, V144
  • [7] The WATCH AF Trial: SmartWATCHes for Detection of Atrial Fibrillation
    Doerr, Marcus
    Nohturfft, Vivien
    Brasier, Noe
    Bosshard, Emil
    Djurdjevic, Aleksandar
    Gross, Stefan
    Raichle, Christina J.
    Rhinisperger, Mattias
    Stoeckli, Raphael
    Eckstein, Jens
    [J]. JACC-CLINICAL ELECTROPHYSIOLOGY, 2019, 5 (02) : 199 - 208
  • [8] Detecting Atrial Fibrillation and Atrial Flutter in Daily Life Using Photoplethysmography Data
    Eerikainen, Linda M.
    Bonomi, Alberto G.
    Schipper, Fons
    Dekker, Lukas R. C.
    de Morree, Helma M.
    Vullings, Rik
    Aarts, Ronald M.
    [J]. IEEE JOURNAL OF BIOMEDICAL AND HEALTH INFORMATICS, 2020, 24 (06) : 1610 - 1618
  • [9] Cardiodiagnostics Based on Photoplethysmographic Signals
    Georgieva-Tsaneva, Galya
    Gospodinova, Evgeniya
    Cheshmedzhiev, Krasimir
    [J]. DIAGNOSTICS, 2022, 12 (02)
  • [10] Han D., 2022, Recent advances involving hardware and algorithmic approaches to combat motion artifacts in photoplethysmographic data