Monitoring microplastic-contaminant sorption processes in real-time using membrane introduction mass spectrometry

被引:0
|
作者
Zvekic, Misha [1 ,2 ]
Vandergrift, Gregory W. [1 ,2 ]
Tong, Christine C. [1 ]
Gill, Chris G. [1 ,2 ,3 ,4 ]
Krogh, Erik T. [1 ,2 ]
机构
[1] Vancouver Isl Univ, Appl Environm Res Labs AERL, Dept Chem, Nanaimo, BC V9R 5S5, Canada
[2] Univ Victoria, Dept Chem, Victoria, BC V8P 5C2, Canada
[3] Simon Fraser Univ, Dept Chem, Burnaby, BC V5A 1S6, Canada
[4] Univ Washington, Dept Environm & Occupat Hlth Sci, Seattle, WA 98195 USA
基金
加拿大自然科学与工程研究理事会;
关键词
ORGANIC-COMPOUNDS; PHARMACEUTICALS; CHEMICALS; POLYMERS; KINETICS; BEHAVIOR; PLASTICS;
D O I
10.1039/d3em00083d
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Microplastics are environmentally ubiquitous and their role in the fate and distribution of trace contaminants is of emerging concern. We report the first use of membrane introduction mass spectrometry to directly monitor the rate and extent of microplastic-contaminant sorption. Target contaminant (naphthalene, anthracene, pyrene, and nonylphenol) sorption behaviours were examined at nanomolar concentrations with four plastic types: low density polyethylene (LDPE), high density polyethylene (HDPE), polypropylene (PP), and polystyrene (PS). Under the conditions employed here, short-term sorption kinetics were assessed using on-line mass spectrometry for up to one hour. Subsequent sorption was followed by periodically measuring contaminant concentrations for up to three weeks. Short-term sorption followed first order kinetics with rate constants that scaled with hydrophobicity for the homologous series of polycyclic aromatic hydrocarbons (PAHs). Sorption rate constants on LDPE for equimolar solutions of naphthalene, anthracene, and pyrene were 0.5, 2.0, and 2.2 h(-1), respectively, while nonylphenol did not sorb to pristine plastics over this time period. Similar trends among contaminants were observed for other pristine plastics with 4- to 10-fold faster sorption rates associated with LDPE when compared to PS and PP. Sorption was largely complete after three weeks, with the percent analyte sorbed ranging from 40-100% across various microplastic-contaminant combinations. Photo-oxidative ageing of LDPE had little effect on PAH sorption. However, a marked increase in nonylphenol sorption was consistent with increased hydrogen-bonding interactions. This work provides kinetic insights into surface interactions and describes a powerful experimental platform to directly observe contaminant sorption behaviours in complex samples under a variety of environmentally relevant conditions.
引用
收藏
页码:1169 / 1180
页数:12
相关论文
共 50 条
  • [31] Application of selected ion flow tube mass spectrometry to real-time atmospheric monitoring
    Prince, Barry J.
    Milligan, Daniel B.
    McEwan, Murray J.
    RAPID COMMUNICATIONS IN MASS SPECTROMETRY, 2010, 24 (12) : 1763 - 1769
  • [32] On-line mass spectrometry: Real-time monitoring and kinetics analysis for the photolysis of idoxifene
    Brum, J
    Dell'Orco, P
    RAPID COMMUNICATIONS IN MASS SPECTROMETRY, 1998, 12 (11) : 741 - 745
  • [33] Monitoring the clandestine synthesis of methamphetamine in real-time with ambient sampling, portable mass spectrometry
    O'Leary, Adam E.
    Hall, Seth E.
    Vircks, Kyle E.
    Mulligan, Christopher C.
    ANALYTICAL METHODS, 2015, 7 (17) : 7156 - 7163
  • [34] Real-time monitoring of the reaction between aniline and acetonylacetone using extractive electorspray ionization tandem mass spectrometry
    Zhang, Xinglei
    Pei, Miaorong
    Wu, Debo
    Yang, Shuiping
    Le, Zhanggao
    SCIENTIFIC REPORTS, 2019, 9 (1)
  • [35] Real-time monitoring of the reaction between aniline and acetonylacetone using extractive electorspray ionization tandem mass spectrometry
    Xinglei Zhang
    Miaorong Pei
    Debo Wu
    Shuiping Yang
    Zhanggao Le
    Scientific Reports, 9
  • [36] Real-Time Monitoring of Volatile Organic Compounds in Ambient Air Using Direct-Injection Mass Spectrometry
    Langford, Vaughan S.
    LC GC NORTH AMERICA, 2022, 40 (04) : 174 - 179
  • [37] Real-Time Monitoring of Lysosomal Membrane Permeabilization Using Acridine Orange
    Eriksson, Ida
    Vainikka, Linda
    Persson, Hans Lennart
    Oellinger, Karin
    METHODS AND PROTOCOLS, 2023, 6 (04)
  • [38] Reversed-phase membrane inlet mass spectrometry applied to the real-time monitoring of low molecular weight alcohols in chloroform
    Creaser, CS
    Lamarca, DG
    Brum, J
    Werner, C
    New, AP
    dos Santos, LMF
    ANALYTICAL CHEMISTRY, 2002, 74 (01) : 300 - 304
  • [39] Real-time, ultrasensitive monitoring of air toxics by laser photoionization time-of-flight mass spectrometry
    Castaldi, MJ
    Senkan, SM
    JOURNAL OF THE AIR & WASTE MANAGEMENT ASSOCIATION, 1998, 48 (01): : 77 - 81
  • [40] Real-time monitoring of hydrogen elimination processes in pulsed-gas PECVD using in situ mass spectroscopy
    Srinivasan, E
    Bordeaux, JS
    Parsons, GN
    ADVANCES IN MICROCRYSTALLINE AND NANOCRYSTALLINE SEMICONDUCTORS - 1996, 1997, 452 : 755 - 760