Monitoring microplastic-contaminant sorption processes in real-time using membrane introduction mass spectrometry

被引:0
|
作者
Zvekic, Misha [1 ,2 ]
Vandergrift, Gregory W. [1 ,2 ]
Tong, Christine C. [1 ]
Gill, Chris G. [1 ,2 ,3 ,4 ]
Krogh, Erik T. [1 ,2 ]
机构
[1] Vancouver Isl Univ, Appl Environm Res Labs AERL, Dept Chem, Nanaimo, BC V9R 5S5, Canada
[2] Univ Victoria, Dept Chem, Victoria, BC V8P 5C2, Canada
[3] Simon Fraser Univ, Dept Chem, Burnaby, BC V5A 1S6, Canada
[4] Univ Washington, Dept Environm & Occupat Hlth Sci, Seattle, WA 98195 USA
基金
加拿大自然科学与工程研究理事会;
关键词
ORGANIC-COMPOUNDS; PHARMACEUTICALS; CHEMICALS; POLYMERS; KINETICS; BEHAVIOR; PLASTICS;
D O I
10.1039/d3em00083d
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Microplastics are environmentally ubiquitous and their role in the fate and distribution of trace contaminants is of emerging concern. We report the first use of membrane introduction mass spectrometry to directly monitor the rate and extent of microplastic-contaminant sorption. Target contaminant (naphthalene, anthracene, pyrene, and nonylphenol) sorption behaviours were examined at nanomolar concentrations with four plastic types: low density polyethylene (LDPE), high density polyethylene (HDPE), polypropylene (PP), and polystyrene (PS). Under the conditions employed here, short-term sorption kinetics were assessed using on-line mass spectrometry for up to one hour. Subsequent sorption was followed by periodically measuring contaminant concentrations for up to three weeks. Short-term sorption followed first order kinetics with rate constants that scaled with hydrophobicity for the homologous series of polycyclic aromatic hydrocarbons (PAHs). Sorption rate constants on LDPE for equimolar solutions of naphthalene, anthracene, and pyrene were 0.5, 2.0, and 2.2 h(-1), respectively, while nonylphenol did not sorb to pristine plastics over this time period. Similar trends among contaminants were observed for other pristine plastics with 4- to 10-fold faster sorption rates associated with LDPE when compared to PS and PP. Sorption was largely complete after three weeks, with the percent analyte sorbed ranging from 40-100% across various microplastic-contaminant combinations. Photo-oxidative ageing of LDPE had little effect on PAH sorption. However, a marked increase in nonylphenol sorption was consistent with increased hydrogen-bonding interactions. This work provides kinetic insights into surface interactions and describes a powerful experimental platform to directly observe contaminant sorption behaviours in complex samples under a variety of environmentally relevant conditions.
引用
收藏
页码:1169 / 1180
页数:12
相关论文
共 50 条
  • [1] Real-time analysis of methanol in air and water by membrane introduction mass spectrometry
    Allen, TM
    Falconer, TM
    Cisper, ME
    Borgerding, AJ
    Wilkerson, CW
    ANALYTICAL CHEMISTRY, 2001, 73 (20) : 4830 - 4835
  • [2] Photocatalytic degradation of phenol and trichloroethylene: On-line and real-time monitoring via membrane introduction mass spectrometry
    Nogueira, RFP
    Alberici, RM
    Mendes, MA
    Jardim, WF
    Eberlin, MN
    INDUSTRIAL & ENGINEERING CHEMISTRY RESEARCH, 1999, 38 (05) : 1754 - 1758
  • [3] Photocatalytic degradation of phenol and trichloroethylene: On-line and real-time monitoring via membrane introduction mass spectrometry
    Department of Civil Engineering, Institute of Chemistry, State University of Campinas-UNICAMP, 13083-970 Campinas, SP, Brazil
    Ind. Eng. Chem. Res., 5 (1754-1758):
  • [4] Real-Time Monitoring of Heterogeneous Catalysis with Mass Spectrometry
    Young, Mark A.
    JOURNAL OF CHEMICAL EDUCATION, 2009, 86 (09) : 1082 - 1084
  • [5] Real-time monitoring of exhaled drugs by mass spectrometry
    Berchtold, Christian
    Bosilkovska, Marija
    Daali, Youssef
    Walder, Bernhard
    Zenobi, Renato
    MASS SPECTROMETRY REVIEWS, 2014, 33 (05) : 394 - 413
  • [6] Real-time reaction monitoring using ion mobility-mass spectrometry
    Harry, Emma L.
    Bristow, Anthony W. T.
    Wilson, Ian D.
    Creaser, Colin S.
    ANALYST, 2011, 136 (08) : 1728 - 1732
  • [7] Real-time broad spectrum characterization of hazardous waste by membrane introduction mass spectrometry.
    Wilkerson, CW
    Hemberger, PH
    Cisper, ME
    Allen, TM
    ABSTRACTS OF PAPERS OF THE AMERICAN CHEMICAL SOCIETY, 1999, 218 : U1071 - U1071
  • [8] Membrane introduction mass spectrometry (MIMS): a versatile tool for direct, real-time chemical measurements
    Krogh, Erik T.
    Gill, Chris G.
    JOURNAL OF MASS SPECTROMETRY, 2014, 49 (12): : 1205 - 1213
  • [9] Real-time monitoring of recombinant bacterial proteins by mass spectrometry
    Jones, JJ
    Wilkins, CL
    Cai, Y
    Beitle, RR
    Liyanage, R
    Lay, JO
    BIOTECHNOLOGY PROGRESS, 2005, 21 (06) : 1754 - 1758
  • [10] Real-time mass spectrometry
    Thorsten Hoffmann
    Analytical and Bioanalytical Chemistry, 2003, 375 : 36 - 37